Q131569312
Dotaz
Zobrazit nápovědu
Reproducible expert-independent flow-cytometric criteria for the differential diagnoses between mature B-cell neoplasms are lacking. We developed an algorithm-driven classification for these lymphomas by flow cytometry and compared it to the WHO gold standard diagnosis. Overall, 662 samples from 662 patients representing 9 disease categories were analyzed at 9 laboratories using the previously published EuroFlow 5-tube-8-color B-cell chronic lymphoproliferative disease antibody panel. Expression levels of all 26 markers from the panel were plotted by B-cell entity to construct a univariate, fully standardized diagnostic reference library. For multivariate data analysis, we subsequently used canonical correlation analysis of 176 training cases to project the multidimensional space of all 26 immunophenotypic parameters into 36 2-dimensional plots for each possible pairwise differential diagnosis. Diagnostic boundaries were fitted according to the distribution of the immunophenotypes of a given differential diagnosis. A diagnostic algorithm based on these projections was developed and subsequently validated using 486 independent cases. Negative predictive values exceeding 92.1% were observed for all disease categories except for follicular lymphoma. Particularly high positive predictive values were returned in chronic lymphocytic leukemia (99.1%), hairy cell leukemia (97.2%), follicular lymphoma (97.2%), and mantle cell lymphoma (95.4%). Burkitt and CD10+ diffuse large B-cell lymphomas were difficult to distinguish by the algorithm. A similar ambiguity was observed between marginal zone, lymphoplasmacytic, and CD10- diffuse large B-cell lymphomas. The specificity of the approach exceeded 98% for all entities. The univariate immunophenotypic library and the multivariate expert-independent diagnostic algorithm might contribute to increased reproducibility of future diagnostics in mature B-cell neoplasms.
- MeSH
- difúzní velkobuněčný B-lymfom * MeSH
- dospělí MeSH
- folikulární lymfom * diagnóza MeSH
- imunofenotypizace MeSH
- lidé MeSH
- průtoková cytometrie metody MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- MeSH
- chlorambucil terapeutické užití MeSH
- chronická lymfatická leukemie diagnóza farmakoterapie epidemiologie MeSH
- dospělí MeSH
- humanizované monoklonální protilátky terapeutické užití MeSH
- komorbidita MeSH
- lidé středního věku MeSH
- lidé MeSH
- prognóza MeSH
- prospektivní studie MeSH
- protinádorové látky terapeutické užití MeSH
- protokoly protinádorové kombinované chemoterapie terapeutické užití MeSH
- reziduální nádor diagnóza farmakoterapie epidemiologie MeSH
- rituximab terapeutické užití MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- dopisy MeSH
- klinické zkoušky, fáze III MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
This commentary discusses particularities of application of the EuroFlow standardization of flow cytometric analyses on three different flow cytometers. The EuroFlow consortium developed a fully standardized approach for flow cytometric immunophenotyping of hematological malignancies and primary immunodeficiencies. Standardized instrument setup is an essential part of EuroFlow standardization. Initially, the EuroFlow Consortium developed and optimized a step-by-step standard operating procedure (SOP) to setup 8-color BD FACSCanto II flow cytometer (Canto), with the later inclusion of Navios (Beckman Coulter) and BD FACSLyric (Lyric). Those SOPs were developed to enable standardized and fully comparable fluorescence measurements in the three flow cytometers. In Canto and Navios, mean fluorescence intensity (MFI) of a reference peak of Rainbow beads calibration particles is used to set up photomultiplier (PMT) voltages for each detector channel in individual instruments to reach the same MFI across distinct instruments. In turn, a new feature of Lyric instruments allows to share collection of attributes that are used to place the positive population at the same position among instruments in the form of assays, as one of its components integrated in the Cytometer Setup and Tracking (CS&T) module. The EuroFlow Lyric assays thus allow for standardized acquisition of 8-color EuroFlow panels on Lyric without the need to setup the PMT voltages on the individual instruments manually. In summary, the standardized instrument setup developed by EuroFlow enables cross-platform inter- and intra-laboratory standardization of flow cytometric measurements. This commentary provides a perspective on the modifications of the standardized EuroFlow instrument setup of Canto, Navios and Lyric instruments that are described in detail in individual instrument-specfic SOPs available at the EuroFlow website.
- MeSH
- imunofenotypizace přístrojové vybavení normy MeSH
- lidé MeSH
- průtoková cytometrie přístrojové vybavení normy MeSH
- referenční standardy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Fluorochrome selection is a key step in designing multi-color antibody panels. The list of available fluorochromes is continuously growing, fitting current needs in clinical flow cytometry to simultaneously use more markers to better define multiple leukocyte subpopulations in a single tube. Several criteria guide fluorochrome selection: i) the fluorescence profiles (excitation and emission), ii) relative brightness, iii) fluorescence overlap, iv) fluorochrome stability, and v) reproducible conjugation to antibodies. Here we used 75 samples (45 bone marrow and 30 blood) to illustrate EuroFlow strategies for evaluation of compatible fluorochromes, and how the results obtained guide fluorochrome selection as a critical step in the antibody-panel building process. Our results allowed identification of optimal fluorescence profiles (e.g. higher fluorescence intensity and/or resolution with limited fluorescence overlap into neighbor channels) for brilliant violet (BV)421 and BV510 in the violet laser and allophycocyanin (APC) hilite 7 (H7) or APC C750 in the red laser vs. other candidate fluorochromes generally applied for the same detectors and here evaluated. Moreover, evaluation of the same characteristics for another group of fluorochromes (e.g. BV605, BV650, PE CF594, AF700 or APC AF700) guided selection of the most appropriate fluorochrome conjugates to be combined in a multi-color antibody panel. Albeit this is a demanding approach, it could be successfully applied for selection of fluorochrome combinations for the EuroFlow antibody panels for diagnosis, classification and monitoring of hematological malignancies and primary immunodeficiencies. Consequently, sets of 8-, 10- and 12-color fluorochrome combinations are proposed as frame of reference for initial antibody panel design.
- MeSH
- fluorescenční barviva * MeSH
- imunofenotypizace metody MeSH
- lidé MeSH
- průtoková cytometrie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
A critical component of the EuroFlow standardization of leukemia/lymphoma immunophenotyping is instrument setup. Initially, the EuroFlow consortium developed a step-by-step standard operating protocol for instrument setup of ≥8-color flow cytometers that were available in 2006, when the EuroFlow activities started. Currently, there are 14 instruments from 9 manufacturers capable of 3-laser excitation and ≥8 color measurements. The specific adaptations required in the instrument set-up to enable them to acquire the standardized 8-color EuroFlow protocols are described here. Overall, all 14 instruments can be fitted with similar violet, blue and red lasers for simultaneous measurements of ≥8 fluorescent dyes. Since individual instruments differ both on their dynamic range (scale) and emission filters, it is not accurate to simply recalculate the target values to different scale, but adjustment of PMT voltages to a given emission filter and fluorochrome, is essential. For this purpose, EuroFlow has developed an approach using Type IIB (spectrally matching) particles to set-up standardized and fully comparable fluorescence measurements, in instruments from different manufacturers, as demonstrated here for the FACSCanto II, and Navios and MACSQuant flow cytometers. Data acquired after such adjustment on any of the tested cytometry platforms could be fully superimposed and therefore analyzed together. The proposed approach can be used to derive target values for any combination of spectrally distinct fluorochromes and any distinct emission filter of any new flow cytometry platform, which enables the measurement of the 8-color EuroFlow panels in a standardized way, by creating superimposable datafiles.
- MeSH
- hematologické nádory diagnóza MeSH
- imunofenotypizace přístrojové vybavení normy MeSH
- lidé MeSH
- průtoková cytometrie přístrojové vybavení normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The fluorescence detected using fluorochrome-labelled monoclonal antibodies depends not only on the abundance of the target antigen, but amongst many other factors also on the effective fluorochrome-to-antibody ratio. The diagnostic approach of the EuroFlow consortium relies on reproducible fluorescence intensities over time. A capture bead system for mouse immunoglobulin light chains was utilized to compare the mean fluorescence intensity of 1323 consecutive antibody lots to the currently used lot of the same monoclonal antibody. In total, 157 different monoclonal antibodies were assessed over seven years. Median relative difference between consecutive lots was 3.8% (range: 0.01% to 164.7%, interquartile range: 1.3% to 10.1%). The relative difference exceeded 20% in 8.8% of all comparisons. FITC labelled monoclonal antibodies (median relative difference: 2.1%) showed a significantly smaller variation between lots than antibodies conjugated to PE (3.5%), PECy7 (3.9%), PerCPCy5.5 (5.8%), APC (5.8%), APCH7 (7.4%), and APCC750 (14.5%). Reagents labelled with Pacific Blue (1.4%), Pacific Orange (2.4%), HV450 (0.7%), and HV500 (1.7%) demonstrated more consistent results compared to conjugates of BV421 (4.1%) and BV510 (16.2%). Additionally, significant differences in lot-to-lot fluorescence stability amongst antibodies labelled with the same fluorochrome were observed between manufacturers. These observations might guide future quality recommendations for the production and application of fluorescence-labelled monoclonal antibodies in multicolor flow cytometry.
BACKGROUND: Chemoimmunotherapy with fludarabine, cyclophosphamide, and rituximab is the standard therapy for physically fit patients with advanced chronic lymphocytic leukaemia. This international phase 3 study compared the efficacy and tolerance of the standard therapy with a potentially less toxic combination consisting of bendamustine and rituximab. METHODS: Treatment-naive fit patients with chronic lymphocytic leukaemia (aged 33-81 years) without del(17p) were enrolled after undergoing a central screening process. Patients were randomly assigned (1:1) with a computer-generated randomisation list using randomly permuted blocks with a block size of eight and were stratified according to participating country and Binet stage. Patients were allocated to receive six cycles of intravenous fludarabine (25 mg/m(2) per day) and cyclophosphamide (250 mg/m(2) per day) for the first 3 days or to intravenous bendamustine (90 mg/m(2) per day) for the first 2 days of each cycle. Rituximab 375 mg/m(2) was given intravenously in both groups on day 0 of cycle 1 and subsequently was given at 500 mg/m(2) during the next five cycles on day 1. The primary endpoint was progression-free survival with the objective to assess non-inferiority of bendamustine and rituximab to the standard therapy. We aimed to show that the 2-year progression-free survival with bendamustine and rituximab was not 67·5% or less with a corresponding non-inferiority margin of 1·388 for the hazard ratio (HR) based on the 90·4% CI. The final analysis was done by intention to treat. The study is registered with ClinicalTrials.gov, number NCT%2000769522. FINDINGS: 688 patients were recruited between Oct 2, 2008, and July 11, 2011, of which 564 patients who met inclusion criteria were randomly assigned. 561 patients were included in the intention-to-treat population: 282 patients in the fludarabine, cyclophosphamide, and rituximab group and 279 in the bendamustine and rituximab group. After a median observation time of 37·1 months (IQR 31·0-45·5) median progression-free survival was 41·7 months (95% CI 34·9-45·3) with bendamustine and rituximab and 55·2 months (95% CI not evaluable) with fludarabine, cyclophosphamide, and rituximab (HR 1·643, 90·4% CI 1·308-2·064). As the upper limit of the 90·4% CI was greater than 1·388 the null hypothesis for the corresponding non-inferiority hypothesis was not rejected. Severe neutropenia and infections were more frequently observed with fludarabine, cyclophosphamide, and rituximab (235 [84%] of 279 vs 164 [59%] of 278, and 109 [39%] vs 69 [25%], respectively) during the study. The increased frequency of infectious complications with fludarabine, cyclophosphamide, and rituximab was more pronounced in patients older than 65 years. INTERPRETATION: The combination of fludarabine, cyclophosphamide, and rituximab remains the standard front-line therapy in fit patients with chronic lymphocytic leukaemia, but bendamustine and rituximab is associated with less toxic effects. FUNDING: Roche Pharma AG, Mundipharma, German Federal Ministry of Education and Research.
- MeSH
- bendamustin hydrochlorid aplikace a dávkování MeSH
- chronická lymfatická leukemie farmakoterapie imunologie patologie MeSH
- cyklofosfamid aplikace a dávkování MeSH
- dospělí MeSH
- imunoterapie * MeSH
- lidé středního věku MeSH
- lidé MeSH
- mezinárodní agentury MeSH
- míra přežití MeSH
- následné studie MeSH
- prognóza MeSH
- protokoly protinádorové kombinované chemoterapie terapeutické užití MeSH
- rituximab aplikace a dávkování MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- staging nádorů MeSH
- vidarabin aplikace a dávkování analogy a deriváty MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky, fáze III MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
Flow cytometric immunophenotyping has become essential for accurate diagnosis, classification, and disease monitoring in hemato-oncology. The EuroFlow Consortium has established a fully standardized "all-in-one" pipeline consisting of standardized instrument settings, reagent panels, and sample preparation protocols and software for data analysis and disease classification. For its reproducible implementation, parallel development of a quality assurance (QA) program was required. Here, we report on the results of four consecutive annual rounds of the novel external QA EuroFlow program. The novel QA scheme aimed at monitoring the whole flow cytometric analysis process (cytometer setting, sample preparation, acquisition and analysis) by reading the median fluorescence intensities (MedFI) of defined lymphocytes' subsets. Each QA participant applied the predefined reagents' panel on blood cells of local healthy donors. A uniform gating strategy was applied to define lymphocyte subsets and to read MedFI values per marker. The MedFI values were compared with reference data and deviations from reference values were quantified using performance score metrics. In four annual QA rounds, we analyzed 123 blood samples from local healthy donors on 14 different instruments in 11 laboratories from nine European countries. The immunophenotype of defined cellular subsets appeared sufficiently standardized to permit unified (software) data analysis. The coefficient of variation of MedFI for 7 of 11 markers performed repeatedly below 30%, average MedFI in each QA round ranged from 86 to 125% from overall median. Calculation of performance scores was instrumental to pinpoint standardization failures and their causes. Overall, the new EuroFlow QA system for the first time allowed to quantify the technical variation that is introduced in the measurement of fluorescence intensities in a multicentric setting over an extended period of time. EuroFlow QA is a proficiency test specific for laboratories that use standardized EuroFlow protocols. It may be used to complement, but not replace, established proficiency tests. © 2014 International Society for Advancement of Cytometry.
- MeSH
- imunofenotypizace metody MeSH
- leukemie klasifikace diagnóza MeSH
- lymfom klasifikace diagnóza MeSH
- podskupiny lymfocytů imunologie MeSH
- průtoková cytometrie metody MeSH
- referenční hodnoty MeSH
- referenční standardy MeSH
- řízení kvality MeSH
- zdraví dobrovolníci pro lékařské studie MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Evropa MeSH
Most consensus leukemia & lymphoma antibody panels consist of lists of markers based on expert opinions, but they have not been validated. Here we present the validated EuroFlow 8-color antibody panels for immunophenotyping of hematological malignancies. The single-tube screening panels and multi-tube classification panels fit into the EuroFlow diagnostic algorithm with entries defined by clinical and laboratory parameters. The panels were constructed in 2-7 sequential design-evaluation-redesign rounds, using novel Infinicyt software tools for multivariate data analysis. Two groups of markers are combined in each 8-color tube: (i) backbone markers to identify distinct cell populations in a sample, and (ii) markers for characterization of specific cell populations. In multi-tube panels, the backbone markers were optimally placed at the same fluorochrome position in every tube, to provide identical multidimensional localization of the target cell population(s). The characterization markers were positioned according to the diagnostic utility of the combined markers. Each proposed antibody combination was tested against reference databases of normal and malignant cells from healthy subjects and WHO-based disease entities, respectively. The EuroFlow studies resulted in validated and flexible 8-color antibody panels for multidimensional identification and characterization of normal and aberrant cells, optimally suited for immunophenotypic screening and classification of hematological malignancies.
- MeSH
- hematologické nádory diagnóza imunologie MeSH
- imunofenotypizace normy MeSH
- leukocyty imunologie patologie MeSH
- lidé MeSH
- monoklonální protilátky diagnostické užití MeSH
- nádorové biomarkery imunologie MeSH
- prognóza MeSH
- průtoková cytometrie normy MeSH
- studie případů a kontrol MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
- Geografické názvy
- Evropa MeSH
The EU-supported EuroFlow Consortium aimed at innovation and standardization of immunophenotyping for diagnosis and classification of hematological malignancies by introducing 8-color flow cytometry with fully standardized laboratory procedures and antibody panels in order to achieve maximally comparable results among different laboratories. This required the selection of optimal combinations of compatible fluorochromes and the design and evaluation of adequate standard operating procedures (SOPs) for instrument setup, fluorescence compensation and sample preparation. Additionally, we developed software tools for the evaluation of individual antibody reagents and antibody panels. Each section describes what has been evaluated experimentally versus adopted based on existing data and experience. Multicentric evaluation demonstrated high levels of reproducibility based on strict implementation of the EuroFlow SOPs and antibody panels. Overall, the 6 years of extensive collaborative experiments and the analysis of hundreds of cell samples of patients and healthy controls in the EuroFlow centers have provided for the first time laboratory protocols and software tools for fully standardized 8-color flow cytometric immunophenotyping of normal and malignant leukocytes in bone marrow and blood; this has yielded highly comparable data sets, which can be integrated in a single database.
- MeSH
- hematologické nádory diagnóza imunologie MeSH
- imunofenotypizace normy MeSH
- laboratoře normy MeSH
- lidé MeSH
- monoklonální protilátky diagnostické užití MeSH
- nádorové biomarkery imunologie MeSH
- prognóza MeSH
- průtoková cytometrie přístrojové vybavení metody normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Geografické názvy
- Evropa MeSH