forward model
Dotaz
Zobrazit nápovědu
Growing evidence shows that epigenetic mechanisms contribute to complex traits, with implications across many fields of biology. In plant ecology, recent studies have attempted to merge ecological experiments with epigenetic analyses to elucidate the contribution of epigenetics to plant phenotypes, stress responses, adaptation to habitat, and range distributions. While there has been some progress in revealing the role of epigenetics in ecological processes, studies with non-model species have so far been limited to describing broad patterns based on anonymous markers of DNA methylation. In contrast, studies with model species have benefited from powerful genomic resources, which contribute to a more mechanistic understanding but have limited ecological realism. Understanding the significance of epigenetics for plant ecology requires increased transfer of knowledge and methods from model species research to genomes of evolutionarily divergent species, and examination of responses to complex natural environments at a more mechanistic level. This requires transforming genomics tools specifically for studying non-model species, which is challenging given the large and often polyploid genomes of plants. Collaboration among molecular geneticists, ecologists and bioinformaticians promises to enhance our understanding of the mutual links between genome function and ecological processes.
- MeSH
- ekologie * MeSH
- ekosystém MeSH
- epigeneze genetická * MeSH
- metylace DNA MeSH
- rostliny * MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
In everyday life, people often need to track moving objects. Recently, a topic of discussion has been whether people rely solely on the locations of tracked objects, or take their directions into account in multiple object tracking (MOT). In the current paper, we pose a related question: do people utilise extrapolation in their gaze behaviour, or, in more practical terms, should the mathematical models of gaze behaviour in an MOT task be based on objects' current, past or anticipated positions? We used a data-driven approach with no a priori assumption about the underlying gaze model. We repeatedly presented the same MOT trials forward and backward and collected gaze data. After reversing the data from the backward trials, we gradually tested different time adjustments to find the local maximum of similarity. In a series of four experiments, we showed that the gaze position lagged by approximately 110 ms behind the scene content. We observed the lag in all subjects (Experiment 1). We further experimented to determine whether tracking workload or predictability of movements affect the size of the lag. Low workload led only to a small non-significant shortening of the lag (Experiment 2). Impairing the predictability of objects' trajectories increased the lag (Experiments 3a and 3b). We tested our observations with predictions of a centroid model: we observed a better fit for a model based on the locations of objects 110 ms earlier. We conclude that mathematical models of gaze behaviour in MOT should account for the lags.
- MeSH
- časové faktory MeSH
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- oční fixace fyziologie MeSH
- pozornost fyziologie MeSH
- psychologické modely * MeSH
- rozpoznávání obrazu fyziologie MeSH
- vnímání pohybu fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Tato práce analyzuje prostorová uspořádání jednotek intenzivní péče pro dospělé (JIP), které vznikly v České republice v roce 2023 v rámci výzvy REACT 98. Bylo provedeno srovnávací hodnocení 17 JIP, které porovnává konstrukční prvky těchto jednotek s posledními doporučeními Evropské společnosti intenzivní medicíny z roku 2011. Šetření se zaměřuje na klíčové parametry, jako je prostorové uspořádání, kapacita lůžek, plocha vyhrazená kolem lůžka pacienta, přístup k přirozenému světlu, dostupnost toalety pro nemocného, prostor pro rodinné příslušníky. Studie konstatuje, že většina hodnocených projektů ve sledovaných parametrech navrhovaná doporučení nenaplňuje a nelze je vnímat jako příklady ideální praxe či vzorové modely architektonické evoluce. Pro budoucnost je důležité, aby vývoj uspořádání JIP odpovídal současným lékařským poznatkům, respektoval doporučení a pomáhal v dosažení optimálního prostředí JIP, které je klíčové pro zlep šení péče o pacienty.
This paper analyses the spatial layout of adult intensive care units (ICUs) that were built in the Czech Republic in 2023 under the REACT 98 call. A comparative evaluation was performed to compare the design features of these units with the latest recommendations of the European Society of Intensive Care Medicine from 2011. The investigation focuses on key parameters such as spatial layout, bed capacity, area dedicated around the patient's bed, access to natural light, availability of toilet facilities for the patient, family areas. The study concludes that most of the evaluated projects do not fulfil the proposed recommendations in the parameters studied and cannot be seen as examples of ideal practice or models of architectural evolution. For the future, it is important that the evolution of ICU layout responds to current medical knowledge, respects the recommendations, and helps in achieving an optimal ICU environment, which is crucial for improving patient care.
- MeSH
- dospělí MeSH
- jednotky intenzivní péče * organizace a řízení statistika a číselné údaje MeSH
- lidé MeSH
- osvětlení MeSH
- pokoje pro pacienty organizace a řízení MeSH
- prostředí zdravotnických zařízení metody organizace a řízení statistika a číselné údaje MeSH
- výstavba, architektura a design nemocnic * metody statistika a číselné údaje MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- MeSH
- elektroencefalografie metody přístrojové vybavení využití MeSH
- hlava MeSH
- lidé MeSH
- magnetoencefalografie metody přístrojové vybavení využití MeSH
- mapování mozku metody přístrojové vybavení MeSH
- počítačové zpracování signálu MeSH
- statistika jako téma metody MeSH
- teoretické modely MeSH
- Check Tag
- lidé MeSH
In this paper, linearized approximations of both the forward and the inverse problems of resonant ultrasound spectroscopy for the determination of mechanical properties of thin surface layers are presented. The linear relations between the frequency shifts induced by the deposition of the layer and the in-plane elastic coefficients of the layer are derived and inverted, the applicability range of the obtained linear model is discussed by a comparison with nonlinear models and finite element method (FEM), and an algorithm for the estimation of experimental errors in the inversely determined elastic coefficients is described. In the final part of the paper, the linearized inverse procedure is applied to evaluate elastic coefficients of a 310 nm thick diamond-like carbon layer deposited on a silicon substrate.
- MeSH
- anatomické modely MeSH
- elektroencefalografie metody přístrojové vybavení využití MeSH
- elektromagnetická pole MeSH
- financování organizované MeSH
- hlava anatomie a histologie fyziologie MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody trendy využití MeSH
- mapování mozku metody přístrojové vybavení MeSH
- mozková kůra anatomie a histologie fyziologie MeSH
- teoretické modely MeSH
- Check Tag
- lidé MeSH
The surface conditions on the Moon are extremely harsh with high doses of ultraviolet (UV) irradiation (26.8 W · m-2 UVC/UVB), wide temperature extremes (-171°C to 140°C), low pressure (10-10 Pa), and high levels of ionizing radiation. External spacecraft surfaces on the Moon are generally >100°C during daylight hours and can reach as high as 140°C at local noon. A Lunar Microbial Survival (LMS) model was developed that estimated (1) the total viable bioburden of all spacecraft landed on the Moon as ∼4.57 × 1010 microbial cells/spores at contact, (2) the inactivation kinetics of Bacillus subtilis spores to vacuum as approaching -2 logs per 2107 days, (3) the inactivation of spores on external surfaces due to concomitant low-pressure and high-temperature conditions as -6 logs per 8 h for local noon conditions, and (4) the ionizing radiation by solar wind particles as approaching -3 logs per lunation on external surfaces only. When the biocidal factors of solar UV, vacuum, high-temperature, and ionizing radiation were combined into an integrated LMS model, a -231 log reduction in viable bioburden was predicted for external spacecraft surfaces per lunation at the equator. Results indicate that external surfaces of landed or crashed spacecraft are unlikely to harbor viable spores after only one lunation, that shallow internal surfaces will be sterilized due to the interactive effects of vacuum and thermal cycling from solar irradiation, and that deep internal surfaces would be affected only by vacuum with a degradation rate of -0.02 logs per lunation.
- MeSH
- Bacillus subtilis fyziologie účinky záření MeSH
- biologické modely * MeSH
- kosmická loď MeSH
- kosmické záření škodlivé účinky MeSH
- Měsíc * MeSH
- mikrobiální viabilita účinky záření MeSH
- mimozemské prostředí MeSH
- simulace kosmického prostředí metody MeSH
- spory bakteriální fyziologie účinky záření MeSH
- ultrafialové záření škodlivé účinky MeSH
- vakuum MeSH
- vysoká teplota MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, U.S. Gov't, Non-P.H.S. MeSH
... Acronyms 6 -- 1) Executive summary 7 -- 2) The GIPA principle 11 -- 3) Setting up the GIPA Workplace Model ... ... Africa 13 -- The HIV/AIDS epidemic in South Africa 13 -- Government reaction 14 -- The GIPA Workplace Model ... ... Effectiveness/impact 42 iv) Sustainability 43 v) Ethical soundness 43 -- 6) Lessons learned 45 -- 7) The way forward ...
UNAIDS best practice collection
72 s. ; 18 cm
- MeSH
- AIDS epidemiologie MeSH
- HIV patogenita MeSH
- Geografické názvy
- jižní Afrika MeSH
- Konspekt
- Lékařské vědy. Lékařství
- NLK Obory
- veřejné zdravotnictví
- dermatovenerologie
Závažnost koronárních lézí vždy představovala významný aspekt péče o pacienty během koronarografického vyšetření. Je prokázáno, že léčba vedená na základě hodnot frakční průtokové rezervy (fractional flow reserve, FFR) má pozitivní vliv na klinický výsledný stav pacienta. Zavádění FFR do klinické praxe v celosvětovém měřítku nicméně zpomalily závažné technické nedostatky. V poslední době byla představena a v klinickém výzkumu ověřována jiná kritéria, jako například kvantitativní poměr průtoků (quantitative flow ratio, QFR). Podle jedné studie používající výpočetní mechaniku tekutin a plynů koreluje QFR s hodnotami FFR a ve srovnání s jinými metodami šetří čas i peníze. QFR představuje novou angiografickou metodu, která pomocí moderního softwaru provádí trojrozměrnou rekonstrukci cév a vytváří modely průtoku. Jedná se tedy o technicky vyspělou metodu a o moderní, účinný a praktický nástroj pro hodnocení koronárních lézí. Cílem tohoto přehledu bylo prozkoumat oblasti případného využití QFR v klinické praxi.
The severity of coronary lesions (CL) has always been an important aspect of patient care during coronary angiography. Fractional flow reserve (FFR)-guided coronary treatments have been shown to have a positive influence on clinical outcomes. However, significant technical flaws in clinical practice have slowed global adoption of FFR. Other indices, such as the quantitative flow ratio (QFR), have recently been created and tested in clinical research. According to a computational fluid dynamics study, QFR has a good correlation with FFR values and saves time and money compared to other methods. QFR is a new angiographic technique that uses modern software to reconstruct three-dimensional vessels and calculate flow models. Modern, effective and usable tool for CL due to significant technical benefits. We aimed to analyze the application areas of the QFR and its potential clinical application in this review.