BACKGROUND AND PURPOSE: Systematic analysis of angulation-related variability of idiopathic normal pressure hydrocephalus imaging biomarkers has not been published yet. Our aim was to evaluate the variability of these radiologic biomarkers with respect to imaging plane angulation. MATERIALS AND METHODS: Eighty subjects (35 with clinically confirmed idiopathic normal pressure hydrocephalus and 45 age- and sex-matched healthy controls) were prospectively enrolled in a 3T brain MR imaging study. Two independent readers assessed 12 radiologic idiopathic normal pressure hydrocephalus biomarkers on sections aligned parallel or perpendicular to the bicallosal, bicommissural, hypophysis-fastigium, and brain stem vertical lines, respectively. RESULTS: Disproportionately enlarged subarachnoid space hydrocephalus, simplified callosal angle, frontal horn diameter, z-Evans Index, and cella media vertical width did not show significant systematic differences in any of 6 section plane combinations studied. The remaining 7 biomarkers (including the Evans Index and callosal angle) showed significant differences in up to 4 of 6 mutually compared section plane combinations. The values obtained from sections aligned with the brain stem vertical line (parallel to the posterior brain stem margin) showed the most deviating results from other section angulations. CONCLUSIONS: Seven of 12 idiopathic normal pressure hydrocephalus biomarkers including the frequently used Evans Index and callosal angle showed statistically significant deviations when measured on sections whose angulations differed or did not comply with the proper section definition published in the original literature. Strict adherence to the methodology of idiopathic normal pressure hydrocephalus biomarker assessment is, therefore, essential to avoid an incorrect diagnosis. Increased radiologic and clinical attention should be paid to the biomarkers showing low angulation-related variability yet high specificity for idiopathic normal pressure hydrocephalus-related morphologic changes such as the z-Evans Index, frontal horn diameter, or disproportionately enlarged subarachnoid space hydrocephalus.
- MeSH
- biologické markery MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- normotenzní hydrocefalus * diagnostické zobrazování MeSH
- průřezové studie MeSH
- reprodukovatelnost výsledků MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND AND PURPOSE: Gadobutrol (Gadavist) and gadoteridol (ProHance) have similar macrocyclic molecular structures, but gadobutrol is formulated at a 2-fold higher (1 mol/L versus 0.5 mol/L) concentration. We sought to determine whether this difference impacts morphologic contrast-enhanced MR imaging. MATERIALS AND METHODS: Two hundred twenty-nine adult patients with suspected or known brain tumors underwent two 1.5T MR imaging examinations with gadoteridol or gadobutrol administered in randomized order at a dose of 0.1 mmol/kg of body weight. Imaging sequences and T1 postinjection timing were identical for both examinations. Three blinded readers evaluated images qualitatively and quantitatively for lesion detection and for accuracy in characterization of histologically confirmed brain tumors. Data were analyzed by using the Wilcoxon signed rank test, the McNemar test, and a mixed model. RESULTS: Two hundred nine patients successfully completed both examinations. No reader noted a significant qualitative or quantitative difference in lesion enhancement, extent, delineation, or internal morphology (P values = .69-1.00). One hundred thirty-nine patients had at least 1 histologically confirmed brain lesion. Two readers found no difference in the detection of patients with lesions (133/139 versus 135/139, P = .317; 137/139 versus 136/139, P = .564), while 1 reader found minimal differences in favor of gadoteridol (136/139 versus 132/139, P = .046). Similar findings were noted for the number of lesions detected and characterization of tumors (malignant/benign). Three-reader agreement for characterization was similar for gadobutrol (66.4% [κ = 0.43]) versus gadoteridol (70.3% [κ = 0.45]). There were no significant differences in the incidence of adverse events (P = .199). CONCLUSIONS: Gadoteridol and gadobutrol at 0.1 mmol/kg of body weight provide similar information for visualization and diagnosis of brain lesions. The 2-fold higher gadolinium concentration of gadobutrol provides no benefit for routine morphologic imaging.
- MeSH
- dospělí MeSH
- gadolinium aplikace a dávkování MeSH
- heterocyklické sloučeniny aplikace a dávkování MeSH
- klinické křížové studie MeSH
- kontrastní látky aplikace a dávkování MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- nádory mozku diagnóza MeSH
- neurozobrazování metody MeSH
- organokovové sloučeniny aplikace a dávkování MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND AND PURPOSE: Gadobenate dimeglumine (MultiHance) has higher r1 relaxivity than gadoterate meglumine (Dotarem) which may permit the use of lower doses for MR imaging applications. Our aim was to compare 0.1- and 0.05-mmol/kg body weight gadobenate with 0.1-mmol/kg body weight gadoterate for MR imaging assessment of brain tumors. MATERIALS AND METHODS: We performed crossover, intraindividual comparison of 0.1-mmol/kg gadobenate with 0.1-mmol/kg gadoterate (Arm 1) and 0.05-mmol/kg gadobenate with 0.1-mmol/kg gadoterate (Arm 2). Adult patients with suspected or known brain tumors were randomized to Arm 1 (70 patients) or Arm 2 (107 patients) and underwent 2 identical examinations at 1.5 T. The agents were injected in randomized-sequence order, and the 2 examinations were separated by 2-14 days. MR imaging scanners, imaging sequences (T1-weighted spin-echo and T1-weighted high-resolution gradient-echo), and acquisition timing were identical for the 2 examinations. Three blinded readers evaluated images for diagnostic information (degree of definition of lesion extent, lesion border delineation, visualization of lesion internal morphology, contrast enhancement) and quantitatively for percentage lesion enhancement and lesion-to-background ratio. Safety assessments were performed. RESULTS: In Arm 1, a highly significant superiority (P < .002) of 0.1-mmol/kg gadobenate was demonstrated by all readers for all end points. In Arm 2, no significant differences (P > .1) were observed for any reader and any end point, with the exception of percentage enhancement for reader 2 (P < .05) in favor of 0.05-mmol/kg gadobenate. Study agent-related adverse events were reported by 2/169 (1.2%) patients after gadobenate and by 5/175 (2.9%) patients after gadoterate. CONCLUSIONS: Significantly superior morphologic information and contrast enhancement are demonstrated on brain MR imaging with 0.1-mmol/kg gadobenate compared with 0.1-mmol/kg gadoterate. No meaningful differences were recorded between 0.05-mmol/kg gadobenate and 0.1-mmol/kg gadoterate.
- MeSH
- dospělí MeSH
- klinické křížové studie MeSH
- kontrastní látky MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- meglumin analogy a deriváty MeSH
- nádory mozku patologie MeSH
- organokovové sloučeniny MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
OBJECTIVE: The aim of this study was to analyse the feasibility and determine the benefits of MRI-based pre-planning with CT/MRI data fusion in patients with cervical cancer treated with radical radiotherapy. METHODS: Patients underwent MRI examination prior to external beam radiotherapy and prior to the first and fourth fraction of brachytherapy with applicators in place. Insertion of applicators at the radiology department was performed under paracervical anaesthesia. The benefit of MRI pre-planning was determined by comparing conventional treatment planning with dose specification to "point A" and dose specification to 90% of the high-risk clinical target volume (HR-CTV D90). Tolerance of MRI evaluation with applicators, coverage of HR-CTV and dose-volume parameters for organs at risk (OAR) has been assessed in 42 brachytherapy procedures. RESULTS: Insertion of applicators at the radiology department was successful in all patients and there were no complications. The target dose was higher for MRI planning than for conventional planning (5.3 Gy vs 4.5 Gy). Maximum doses in the bladder and rectum were significantly lower (p<0.05) for MRI planning than for the conventional approach (6.49 Gy vs 7.45 Gy for bladder; 4.57 Gy vs 5.06 Gy for rectum). We found no correlation between the International Commission on Radiation Units (ICRU) point dose for OAR and the maximum dose in OAR. Nevertheless, a strong correlation between the maximum dose in OAR and the minimal dose in a volume of 2 cm(3) has been observed. CONCLUSION: MRI-based pre-planning with consecutive CT/MRI data fusion is feasible and safe, with the advantage of increasing the dose to the tumour and decreasing the dose to the organs at risk.
- MeSH
- brachyterapie metody MeSH
- celková dávka radioterapie MeSH
- kritické orgány MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- močový měchýř patologie účinky záření MeSH
- nádory děložního čípku diagnóza patologie radioterapie MeSH
- plánování radioterapie pomocí počítače metody MeSH
- počítačová rentgenová tomografie MeSH
- rektum patologie účinky záření MeSH
- studie proveditelnosti MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH