BACKGROUND: PICC is routinely inserted with assistance of ultrasonography and/or ECG navigation (RI- routine insertion). Only in a minority of patients the insertion of a PICC is difficult and fluoroscopic visualization with introduction of special guidewire is necessary for the success of the procedure (DI-difficult insertion). The aim of the study was to evaluate whether DI can be predicted and associated with a risk of complications during follow-up. METHODS: The study included patients who had a PICC insertion in 2022. The number of patients with RI and DI was recorded and the significance of selected parameters during insertion and the frequency of complications during 1 month follow-up was compared. RESULTS: About 1404 patients had successful PICC insertion in 2022, RI in 1360 (96.8%) and DI in 44 patients (3.2%). There was no significant effect of age, gender, selected vein, its size, insertion site, and tunneling on the course of PICC insertion. However the number of punctures for needle insertion was higher in DI. The complication rate during 1 month follow-up in DI was 9 (20.4%) versus 101 patients (7.4%) in RI (p = 0.002). CONCLUSION: PICC insertion was successful in both RI and DI patients. Of the analyzed parameters, the number of needle punctures was associated with DI, and complications during the 1-month follow-up were more frequently noted in the DI group.
- MeSH
- časové faktory MeSH
- dospělí MeSH
- hodnocení rizik MeSH
- intervenční radiografie škodlivé účinky MeSH
- intervenční ultrasonografie * MeSH
- katetrizace centrálních vén škodlivé účinky přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- periferní katetrizace * škodlivé účinky MeSH
- punkce * MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: This study aimed to evaluate the safety and performance of PowerPICC catheters in a real-world setting. DESIGN: Prospective, observational, multicentre study. SETTING: Nine European countries, involving 14 centres. PARTICIPANTS: General patient population. INTERVENTION: PowerPICC catheter inserted by the clinician as standard of care with routinely collected outcomes followed through device removal or 180 days postinsertion. PRIMARY AND SECONDARY OUTCOMES MEASURES: Safety and performance outcomes were assessed for PowerPICC, PowerPICC SOLO 2 and PowerGroshong PICC. The primary safety endpoint was the incidence of symptomatic venous thrombosis (VT), and secondary safety endpoints included phlebitis, extravasation, vessel laceration, vessel perforation local infection, accidental dislodgment and catheter-related bloodstream infection (CRBSI). The primary performance endpoint was the percentage of patients whose PowerPICC device remained in place through the completion of therapy. The secondary performance endpoints included catheter patency, placement success in a single attempt and usability. RESULTS: The enrolled patients (N=451) received either PowerPICC, PowerPICC SOLO 2 or PowerGroshong PICC catheters. Across all devices, 1.6% of patients developed symptomatic VT, and CRBSI occurred in 1.6% of patients. There were no cases of phlebitis or extravasation and only three cases of vein laceration or vein perforation. The catheters showed high success rates in completing therapy (81.8%), maintaining patency (93.9%) and achieving successful placement in a single attempt (90.4%). Clinicians overwhelmingly agreed that both the guidewire and stylet (93.3% and 94.4%, respectively) were easy or very easy to use. CONCLUSIONS: This study demonstrates the safety and performance of PowerPICC catheters across diverse settings and patient cohorts in real-world hospital settings across Europe. The findings indicate that these catheters are safe and can be effectively used in the general patient setting and when inserted by a variety of clinicians. The low incidence of complications and high success rates further support the clinical utility of these catheters. TRIAL REGISTRATION NUMBER: NCT04263649.
- MeSH
- centrální žilní katétry škodlivé účinky MeSH
- dospělí MeSH
- flebitida etiologie epidemiologie MeSH
- katetrizace centrálních vén škodlivé účinky přístrojové vybavení metody MeSH
- katétrové infekce * epidemiologie prevence a kontrola MeSH
- lidé středního věku MeSH
- lidé MeSH
- periferní katetrizace škodlivé účinky přístrojové vybavení MeSH
- prospektivní studie MeSH
- senioři MeSH
- zaváděcí katétry škodlivé účinky MeSH
- žilní trombóza epidemiologie etiologie prevence a kontrola MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- Geografické názvy
- Evropa MeSH
BACKGROUND: Veno-arterial extracorporeal membrane oxygenation can be vital to support patients in severe or rapidly progressing cardiogenic shock. In cases of left ventricular distension, left ventricular decompression during veno-arterial extracorporeal membrane oxygenation may be a crucial factor influencing the patient outcome. Application of a double lumen arterial cannula for a left ventricular unloading is an alternative, straightforward method for left ventricular decompression during extracorporeal membrane oxygenation in a veno-arterial configuration. OBJECTIVES: The purpose of this article is to use a mathematical model of the human adult cardiovascular system to analyze the left ventricular function of a patient in cardiogenic shock supported by veno-arterial extracorporeal membrane oxygenation with and without the application of left ventricular unloading using a novel double lumen arterial cannula. METHODS: A lumped model of cardiovascular system hydraulics has been coupled with models of non-pulsatile veno-arterial extracorporeal membrane oxygenation, a standard venous cannula, and a drainage lumen of a double lumen arterial cannula. Cardiogenic shock has been induced by decreasing left ventricular contractility to 10% of baseline normal value. RESULTS: The simulation results indicate that applying double lumen arterial cannula during veno-arterial extracorporeal membrane oxygenation is associated with reduction of left ventricular end-systolic volume, end-diastolic volume, end-systolic pressure, and end-diastolic pressure. CONCLUSIONS: A double lumen arterial cannula is a viable alternative less invasive method for left ventricular decompression during veno-arterial extracorporeal membrane oxygenation. However, to allow for satisfactory extracorporeal membrane oxygenation flow, the cannula design has to be revisited.
- MeSH
- chirurgická dekomprese přístrojové vybavení metody MeSH
- design vybavení metody MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory chirurgie MeSH
- kanyla * MeSH
- kardiogenní šok * patofyziologie chirurgie MeSH
- katetrizace centrálních vén přístrojové vybavení metody MeSH
- katetrizace metody MeSH
- lidé MeSH
- mimotělní membránová oxygenace * přístrojové vybavení metody MeSH
- počítačová simulace MeSH
- reprodukovatelnost výsledků MeSH
- srdeční komory patofyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIM: The evaluation of the incidence of symptomatic upper limb venous thrombosis (ULVT) associated with midline catheters in patients admitted to the hospital. METHODS: The frequency of symptomatic ULVT diagnosed in a group of patients with midline catheters confirmed by sonographic examination in hospitalised patients at Faculty Hospital over the period of 1 year. RESULTS: Four hundred thirty-nine midline catheters were inserted in 430 patients (250 women and 180 men) during year 2015. Nine patients had two midline catheters. The average age of the patient was 68 years (range: 19-96 years). The median time of midline catheter introduction into a vein was 10 days (range: 1-112 days). Symptomatic thrombosis was diagnosed in 20 patients (4.5%), 3.3/1000 catheter days. It was associated with gender (male) and midline insertion in the cephalic vein. CONCLUSION: The risk of upper limb symptomatic thrombosis associated with midline catheters during a stay in the hospital should be taken into consideration when indicating optimal venous access.
- MeSH
- časové faktory MeSH
- centrální žilní katétry škodlivé účinky MeSH
- design vybavení MeSH
- dospělí MeSH
- hluboká žilní trombóza horní končetiny diagnostické zobrazování epidemiologie MeSH
- incidence MeSH
- katetrizace centrálních vén škodlivé účinky přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- příjem pacientů MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- zaváděcí katétry škodlivé účinky MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
- MeSH
- katetrizace centrálních vén * metody přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- zaváděcí katétry normy škodlivé účinky MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- Publikační typ
- přehledy MeSH
- Klíčová slova
- invazivní vstupy,
- MeSH
- adheziva MeSH
- antiinfekční látky lokální MeSH
- centrální žilní katétry * mikrobiologie normy škodlivé účinky MeSH
- katetrizace centrálních vén * normy ošetřování přístrojové vybavení MeSH
- katétrové infekce prevence a kontrola MeSH
- lidé MeSH
- obvazy MeSH
- personál sesterský nemocniční výchova MeSH
- pilotní projekty MeSH
- resuscitační péče normy MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- hodnotící studie MeSH
BACKGROUND: Hemodialysis (HD) in children with a concomitant ventriculoperitoneal shunt (VPS) is rare. Registry data suggest that peritoneal dialysis with a VPS is safe, but little is known about HD in the presence of a VPS. METHODS: We performed a 10-year survey to determine the prevalence of a VPS, complications and outcome in children with a VPS on HD in 15 dialysis units from the 13 countries participating in the European Pediatric Dialysis Working Group. RESULTS: Eleven cases of HD with a VPS were reported (prevalence 1.33 %; 328 patient-months) and compared with prospective Registry data. The median age at start of dialysis was 9.6 [inter-quartile range (IQR) 1.0-15.0] years and median HD vintage was 2.4 (IQR 1.7-3.0) years. Dialysis was performed through a central venous line (CVL) and through an arteriovenous fistula in six and five children, respectively. Three CVL infections occurred in two children, but these children did not develop VPS infections or meningitis. Symptoms of hemodynamic instability were reported in six (55 %) children at least once per week, with hypotension or hypertension occurring in four of these children and nausea, vomiting and headaches occurring in two; four other children reported less frequent symptoms. Seizures on dialysis occurred in two children, at a frequency of less than once per month, with one child also experiencing visual disturbances. During follow-up (median 4.0; IQR 0.38-7.63 years), three children remained on HD and eight had a functioning transplant. No patients were switched to PD. CONCLUSIONS: Hemodialysis in children with a VPS is safe, but associated with frequent symptoms of hemodynamic instability. No episodes of VPS infection or meningitis were seen among the children in the survey, not even in those with CVL sepsis.
- MeSH
- arteriovenózní zkrat škodlivé účinky MeSH
- časové faktory MeSH
- centrální žilní katétry škodlivé účinky MeSH
- chronická renální insuficience diagnóza terapie MeSH
- dialýza ledvin škodlivé účinky MeSH
- dítě MeSH
- hodnocení rizik MeSH
- hypertenze diagnóza etiologie MeSH
- hypotenze diagnóza etiologie MeSH
- katetrizace centrálních vén škodlivé účinky přístrojové vybavení MeSH
- katétrové infekce diagnóza mikrobiologie MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- předškolní dítě MeSH
- průzkumy a dotazníky MeSH
- průzkumy zdravotní péče MeSH
- retrospektivní studie MeSH
- rizikové faktory MeSH
- transplantace ledvin MeSH
- věkové faktory MeSH
- ventrikuloperitoneální zkrat škodlivé účinky přístrojové vybavení MeSH
- výsledek terapie MeSH
- záchvaty diagnóza etiologie MeSH
- zaváděcí katétry škodlivé účinky MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- Geografické názvy
- Evropa MeSH