Onland, Wes OR 0000000296230606 Dotaz Zobrazit nápovědu
OBJECTIVE: This randomised study in preterm infants on non-invasive respiratory support investigated the effectiveness of automated oxygen control (A-FiO2) in keeping the oxygen saturation (SpO2) within a target range (TR) during a 28-day period compared with manual titration (M-FiO2). DESIGN: A single-centre randomised control trial. SETTING: A level III neonatal intensive care unit. PATIENTS: Preterm infants (<28 weeks' gestation) on non-invasive respiratory support. INTERVENTIONS: A-FiO2 versus M-FiO2 control. METHODS: Main outcomes were the proportion of time spent and median area of episodes in the TR, hyperoxaemia, hypoxaemia and the trend over 28 days using a linear random intercept model. RESULTS: 23 preterm infants (median gestation 25.7 weeks; birth weight 820 g) were randomised. Compared with M-FiO2, the time spent within TR was higher in the A-FiO2 group (68.7% vs 48.0%, p<0.001). Infants in the A-FiO2 group spent less time in hyperoxaemia (13.8% vs 37.7%, p<0.001), but no difference was found in hypoxaemia. The time-based analyses showed that the A-FiO2 efficacy may differ over time, especially for hypoxaemia. Compared with the M-FiO2 group, the A-FiO2 group had a larger intercept but with an inversed slope for the daily median area below the TR (intercept 70.1 vs 36.3; estimate/day -0.70 vs 0.69, p<0.001). CONCLUSION: A-FiO2 control was superior to manual control in keeping preterm infants on non-invasive respiratory support in a prespecified TR over a period of 28 days. This improvement may come at the expense of increased time below the TR in the first days after initiating A-FiO2 control. TRIAL REGISTRATION NUMBER: NTR6731.
- MeSH
- hypoxie prevence a kontrola MeSH
- klinické křížové studie MeSH
- kojenec MeSH
- kyslík * MeSH
- lidé MeSH
- novorozenec nedonošený * MeSH
- novorozenec MeSH
- porodní hmotnost MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
- randomizované kontrolované studie MeSH
OBJECTIVE: This study aims to evaluate the performance of the fabian-Predictive-Intelligent-Control-of-Oxygenation (PRICO) system for automated control of the fraction of inspired oxygen (FiO2). DESIGN: Multicentre randomised cross-over study. SETTING: Five neonatal intensive care units experienced with automated control of FiO2 and the fabian ventilator. PATIENTS: 39 infants: median gestational age of 27 weeks (IQR: 26-30), postnatal age 7 days (IQR: 2-17), weight 1120 g (IQR: 915-1588), FiO2 0.32 (IQR: 0.22-0.43) receiving both non-invasive (27) and invasive (12) respiratory support. INTERVENTION: Randomised sequential 24-hour periods of automated and manual FiO2 control. MAIN OUTCOME MEASURES: Proportion (%) of time in normoxaemia (90%-95% with FiO2>0.21 and 90%-100% when FiO2=0.21) was the primary endpoint. Secondary endpoints were severe hypoxaemia (<80%) and severe hyperoxaemia (>98% with FiO2>0.21) and prevalence of episodes ≥60 s at these two SpO2 extremes. RESULTS: During automated control, subjects spent more time in normoxaemia (74%±22% vs 51%±22%, p<0.001) with less time above and below (<90% (9%±8% vs 12%±11%, p<0.001) and >95% with FiO2>0.21 (16%±19% vs 35%±24%) p<0.001). They spent less time in severe hyperoxaemia (1% (0%-3.5%) vs 5% (1%-10%), p<0.001) but exposure to severe hypoxaemia was low in both arms and not different. The differences in prolonged episodes of SpO2 were consistent with the times at extremes. CONCLUSIONS: This study demonstrates the ability of the PRICO automated oxygen control algorithm to improve the maintenance of SpO2 in normoxaemia and to avoid hyperoxaemia without increasing hypoxaemia.
- MeSH
- hyperoxie prevence a kontrola MeSH
- hypoxie MeSH
- jednotky intenzivní péče o novorozence * MeSH
- klinické křížové studie * MeSH
- kyslík krev aplikace a dávkování MeSH
- lidé MeSH
- novorozenec nedonošený MeSH
- novorozenec MeSH
- oxygenoterapie metody škodlivé účinky přístrojové vybavení MeSH
- oxymetrie metody MeSH
- saturace kyslíkem * MeSH
- umělé dýchání škodlivé účinky MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- pragmatická klinická studie MeSH
- randomizované kontrolované studie MeSH
OBJECTIVE: Neonatal exposure to episodic hypoxemia and hyperoxemia is highly relevant to outcomes. Our goal was to investigate the differences in the frequency and duration of extreme low and high SpO2 episodes between automated and manual inspired oxygen control. DESIGN: Post-hoc analysis of a cohort from prospective randomized cross-over studies. SETTING: Seven tertiary care neonatal intensive care units. PATIENTS: Fifty-eight very preterm neonates (32 or less weeks PMA) receiving respiratory support and supplemental oxygen participating in an automated versus manual oxygen control cross-over trial. MAIN MEASURES: Extreme hypoxemia was defined as a SpO2 < 80%, extreme hyperoxemia as a SpO2 > 98%. Episode duration was categorized as < 5 seconds, between 5 to < 30 seconds, 30 to < 60 seconds, 60 to < 120 seconds, and 120 seconds or longer. RESULTS: The infants were of a median postmenstrual age of 29 (28-31) weeks, receiving a median FiO2 of 0.28 (0.25-0.32) with mostly receiving non-invasive respiratory support (83%). While most of the episodes were less than 30 seconds, longer episodes had a marked effect on total time exposure to extremes. The time differences in each of the three longest durations episodes (30, 60, and 120 seconds) were significantly less during automated than during manual control (p < 0.001). Nearly two-third of the reduction of total time spent at the extremes between automated and manual control (3.8 to 2.1% for < 80% SpO2 and 3.0 to 1.6% for > 98% SpO2) was seen in the episodes of at least 60 seconds. CONCLUSIONS: This study shows that the majority of episodes preterm infants spent in SpO2 extremes are of short duration regardless of manual or automated control. However, the infrequent longer episodes not only contribute the most to the total exposure, but also their reduction in frequency to the improvement associated with automated control.
- MeSH
- hypoxie etiologie terapie MeSH
- kojenec MeSH
- kyslík * MeSH
- lidé MeSH
- novorozenec nedonošený * MeSH
- novorozenec MeSH
- oxymetrie MeSH
- prospektivní studie MeSH
- retrospektivní studie MeSH
- Check Tag
- kojenec MeSH
- lidé MeSH
- novorozenec MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVE: To investigate the effect of different pulse oximetry (SpO2) target range settings during automated fraction of inspired oxygen control (A-FiO2) on time spent within a clinically set SpO2 alarm range in oxygen-dependent infants on noninvasive respiratory support. STUDY DESIGN: Forty-one preterm infants (gestational age [median] 26 weeks, age [median] 21 days) on FiO2 >0.21 receiving noninvasive respiratory support were subjected to A-FiO2 using 3 SpO2 target ranges (86%-94%, 88%-92%, or 89%-91%) in random order for 24 hours each. Before switching to the next target range, SpO2 was manually controlled for 24 hours (washout period). The primary outcome was the time spent within the clinically set alarm limits of 86%-94%. RESULTS: The percent time within the 86%-94% SpO2 alarm range was similar for all 3 A-FiO2 target ranges (74%). Time spent in hyperoxemia was not significantly different between target ranges. However, the time spent in severe hypoxemia (SpO2 <80%) was significantly reduced during the narrowed target ranges of A-FiO2 (88%-92%; 1.9%, 89%-91%; 1.7%) compared with the wide target range (86%-94%; 3.4%, P < .001). There were no differences between the 88%-92% and 89-91% target range. CONCLUSIONS: Narrowing the target range of A-FiO2 to the desired median ±2% is effective in reducing the time spent in hypoxemia, without increasing the risk of hyperoxemia. TRIAL REGISTRATION: www.trialregister.nl: NTR4368.
- MeSH
- časové faktory MeSH
- jednotky intenzivní péče o novorozence MeSH
- klinické alarmy statistika a číselné údaje MeSH
- klinické křížové studie MeSH
- kyslík krev MeSH
- lidé MeSH
- neinvazivní ventilace metody MeSH
- novorozenec nedonošený MeSH
- novorozenec MeSH
- oxymetrie metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Nizozemsko MeSH
OBJECTIVE: To determine the efficacy and safety of automated adjustment of the fraction of inspired oxygen (FiO2) in maintaining arterial oxygen saturation (SpO2) within a higher (91%-95%) and a lower (89%-93%) target range in preterm infants. STUDY DESIGN: Eighty preterm infants (gestational age [median]: 26 weeks, age [median] 18 days) on noninvasive (n = 50) and invasive (n = 30) respiratory support with supplemental oxygen, were first randomized to one of the SpO2 target ranges and then treated with automated FiO2 (A-FiO2) and manual FiO2 (M-FiO2) oxygen control for 24 hours each, in random sequence. RESULTS: The percent time within the target range was higher during A-FiO2 compared with M-FiO2 control. This effect was more pronounced in the lower SpO2 target range (62 ± 17% vs 54 ± 16%, P < .001) than in the higher SpO2 target range (62 ± 17% vs 58 ± 15%, P < .001). The percent time spent below the target or in hypoxemia (SpO2 <80%) was consistently reduced during A-FiO2, independent of the target range. The time spent above the target range or at extreme hyperoxemia (SpO2 >98%) was only reduced during A-FiO2 when targeting the lower SpO2 range (89%-93%). These outcomes did not differ between infants on noninvasive and invasive respiratory support. Manual adjustments were significantly reduced during A-FiO2 control. CONCLUSIONS: A-FiO2 control improved SpO2 targeting across different SpO2 ranges and reduced hypoxemia in preterm infants on noninvasive and invasive respiratory support. TRIAL REGISTRATION: ISRCTN 56626482.
- MeSH
- jednotky intenzivní péče o novorozence MeSH
- klinické křížové studie MeSH
- kyslík krev terapeutické užití MeSH
- lidé MeSH
- novorozenec nedonošený MeSH
- novorozenec MeSH
- oxymetrie metody MeSH
- umělé dýchání metody MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- novorozenec MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Evropa MeSH
- Kanada MeSH
BACKGROUND: Conflicting evidence exists on whether smoking acts as an effect modifier of the association between APOE genotype and risk of coronary heart disease (CHD). METHODS AND RESULTS: We searched PubMed and EMBASE to June 11, 2013 for published studies reporting APOE genotype, smoking status and CHD events and added unpublished data from population cohorts. We tested for presence of effect modification by smoking status in the relationship between APOE genotype and risk of CHD using likelihood ratio test. In total 13 studies (including unpublished data from eight cohorts) with 10,134 CHD events in 130,004 individuals of European descent were identified. The odds ratio (OR) for CHD risk from APOE genotype (ε4 carriers versus non-carriers) was 1.06 (95% confidence interval (CI): 1.01, 1.12) and for smoking (present vs. past/never smokers) was OR 2.05 (95%CI: 1.95, 2.14). When the association between APOE genotype and CHD was stratified by smoking status, compared to non-ε4 carriers, ε4 carriers had an OR of 1.11 (95%CI: 1.02, 1.21) in 28,789 present smokers and an OR of 1.04 (95%CI 0.98, 1.10) in 101,215 previous/never smokers, with no evidence of effect modification (P-value for heterogeneity = 0.19). Analysis of pack years in individual participant data of >60,000 with adjustment for cardiovascular traits also failed to identify evidence of effect modification. CONCLUSIONS: In the largest analysis to date, we identified no evidence for effect modification by smoking status in the association between APOE genotype and risk of CHD.
- MeSH
- alely MeSH
- apolipoprotein E4 genetika MeSH
- dospělí MeSH
- genotyp * MeSH
- heterozygot MeSH
- interakce genů a prostředí MeSH
- kohortové studie MeSH
- koronární nemoc genetika MeSH
- kouření škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- rizikové faktory MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- práce podpořená grantem MeSH
- přehledy MeSH
- Research Support, N.I.H., Extramural MeSH
BACKGROUND & AIMS: Human studies examining associations between circulating levels of insulin-like growth factor 1 (IGF1) and insulin-like growth factor binding protein 3 (IGFBP3) and colorectal cancer risk have reported inconsistent results. We conducted complementary serologic and Mendelian randomization (MR) analyses to determine whether alterations in circulating levels of IGF1 or IGFBP3 are associated with colorectal cancer development. METHODS: Serum levels of IGF1 were measured in blood samples collected from 397,380 participants from the UK Biobank, from 2006 through 2010. Incident cancer cases and cancer cases recorded first in death certificates were identified through linkage to national cancer and death registries. Complete follow-up was available through March 31, 2016. For the MR analyses, we identified genetic variants associated with circulating levels of IGF1 and IGFBP3. The association of these genetic variants with colorectal cancer was examined with 2-sample MR methods using genome-wide association study consortia data (52,865 cases with colorectal cancer and 46,287 individuals without [controls]) RESULTS: After a median follow-up period of 7.1 years, 2665 cases of colorectal cancer were recorded. In a multivariable-adjusted model, circulating level of IGF1 associated with colorectal cancer risk (hazard ratio per 1 standard deviation increment of IGF1, 1.11; 95% confidence interval [CI] 1.05-1.17). Similar associations were found by sex, follow-up time, and tumor subsite. In the MR analyses, a 1 standard deviation increment in IGF1 level, predicted based on genetic factors, was associated with a higher risk of colorectal cancer risk (odds ratio 1.08; 95% CI 1.03-1.12; P = 3.3 × 10-4). Level of IGFBP3, predicted based on genetic factors, was associated with colorectal cancer risk (odds ratio per 1 standard deviation increment, 1.12; 95% CI 1.06-1.18; P = 4.2 × 10-5). Colorectal cancer risk was associated with only 1 variant in the IGFBP3 gene region (rs11977526), which also associated with anthropometric traits and circulating level of IGF2. CONCLUSIONS: In an analysis of blood samples from almost 400,000 participants in the UK Biobank, we found an association between circulating level of IGF1 and colorectal cancer. Using genetic data from 52,865 cases with colorectal cancer and 46,287 controls, a higher level of IGF1, determined by genetic factors, was associated with colorectal cancer. Further studies are needed to determine how this signaling pathway might contribute to colorectal carcinogenesis.
- MeSH
- hodnocení rizik metody MeSH
- IGFBP-3 krev genetika MeSH
- incidence MeSH
- insulinu podobný růstový faktor I analýza genetika MeSH
- insulinu podobný růstový faktor II analýza MeSH
- jednonukleotidový polymorfismus MeSH
- kolorektální nádory krev epidemiologie genetika MeSH
- lidé středního věku MeSH
- lidé MeSH
- mendelovská randomizace MeSH
- nádorové biomarkery krev genetika MeSH
- následné studie MeSH
- registrace statistika a číselné údaje MeSH
- rizikové faktory MeSH
- senioři MeSH
- sexuální faktory MeSH
- studie případů a kontrol MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
- Research Support, N.I.H., Intramural MeSH
- Geografické názvy
- Spojené království MeSH
BACKGROUND: Statin treatment and variants in the gene encoding HMG-CoA reductase are associated with reductions in both the concentration of LDL cholesterol and the risk of coronary heart disease, but also with modest hyperglycaemia, increased bodyweight, and modestly increased risk of type 2 diabetes, which in no way offsets their substantial benefits. We sought to investigate the associations of LDL cholesterol-lowering PCSK9 variants with type 2 diabetes and related biomarkers to gauge the likely effects of PCSK9 inhibitors on diabetes risk. METHODS: In this mendelian randomisation study, we used data from cohort studies, randomised controlled trials, case control studies, and genetic consortia to estimate associations of PCSK9 genetic variants with LDL cholesterol, fasting blood glucose, HbA1c, fasting insulin, bodyweight, waist-to-hip ratio, BMI, and risk of type 2 diabetes, using a standardised analysis plan, meta-analyses, and weighted gene-centric scores. FINDINGS: Data were available for more than 550 000 individuals and 51 623 cases of type 2 diabetes. Combined analyses of four independent PCSK9 variants (rs11583680, rs11591147, rs2479409, and rs11206510) scaled to 1 mmol/L lower LDL cholesterol showed associations with increased fasting glucose (0·09 mmol/L, 95% CI 0·02 to 0·15), bodyweight (1·03 kg, 0·24 to 1·82), waist-to-hip ratio (0·006, 0·003 to 0·010), and an odds ratio for type diabetes of 1·29 (1·11 to 1·50). Based on the collected data, we did not identify associations with HbA1c (0·03%, -0·01 to 0·08), fasting insulin (0·00%, -0·06 to 0·07), and BMI (0·11 kg/m2, -0·09 to 0·30). INTERPRETATION: PCSK9 variants associated with lower LDL cholesterol were also associated with circulating higher fasting glucose concentration, bodyweight, and waist-to-hip ratio, and an increased risk of type 2 diabetes. In trials of PCSK9 inhibitor drugs, investigators should carefully assess these safety outcomes and quantify the risks and benefits of PCSK9 inhibitor treatment, as was previously done for statins. FUNDING: British Heart Foundation, and University College London Hospitals NHS Foundation Trust (UCLH) National Institute for Health Research (NIHR) Biomedical Research Centre.
- MeSH
- diabetes mellitus 2. typu krev diagnóza genetika MeSH
- genetická predispozice k nemoci genetika MeSH
- genetická variace genetika MeSH
- kohortové studie MeSH
- krevní glukóza metabolismus MeSH
- LDL-cholesterol krev genetika MeSH
- lidé MeSH
- mendelovská randomizace metody MeSH
- proproteinkonvertasa subtilisin/kexin typu 9 genetika MeSH
- randomizované kontrolované studie jako téma metody MeSH
- studie případů a kontrol MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Statins increase the risk of new-onset type 2 diabetes mellitus. We aimed to assess whether this increase in risk is a consequence of inhibition of 3-hydroxy-3-methylglutaryl-CoA reductase (HMGCR), the intended drug target. METHODS: We used single nucleotide polymorphisms in the HMGCR gene, rs17238484 (for the main analysis) and rs12916 (for a subsidiary analysis) as proxies for HMGCR inhibition by statins. We examined associations of these variants with plasma lipid, glucose, and insulin concentrations; bodyweight; waist circumference; and prevalent and incident type 2 diabetes. Study-specific effect estimates per copy of each LDL-lowering allele were pooled by meta-analysis. These findings were compared with a meta-analysis of new-onset type 2 diabetes and bodyweight change data from randomised trials of statin drugs. The effects of statins in each randomised trial were assessed using meta-analysis. FINDINGS: Data were available for up to 223 463 individuals from 43 genetic studies. Each additional rs17238484-G allele was associated with a mean 0·06 mmol/L (95% CI 0·05-0·07) lower LDL cholesterol and higher body weight (0·30 kg, 0·18-0·43), waist circumference (0·32 cm, 0·16-0·47), plasma insulin concentration (1·62%, 0·53-2·72), and plasma glucose concentration (0·23%, 0·02-0·44). The rs12916 SNP had similar effects on LDL cholesterol, bodyweight, and waist circumference. The rs17238484-G allele seemed to be associated with higher risk of type 2 diabetes (odds ratio [OR] per allele 1·02, 95% CI 1·00-1·05); the rs12916-T allele association was consistent (1·06, 1·03-1·09). In 129 170 individuals in randomised trials, statins lowered LDL cholesterol by 0·92 mmol/L (95% CI 0·18-1·67) at 1-year of follow-up, increased bodyweight by 0·24 kg (95% CI 0·10-0·38 in all trials; 0·33 kg, 95% CI 0·24-0·42 in placebo or standard care controlled trials and -0·15 kg, 95% CI -0·39 to 0·08 in intensive-dose vs moderate-dose trials) at a mean of 4·2 years (range 1·9-6·7) of follow-up, and increased the odds of new-onset type 2 diabetes (OR 1·12, 95% CI 1·06-1·18 in all trials; 1·11, 95% CI 1·03-1·20 in placebo or standard care controlled trials and 1·12, 95% CI 1·04-1·22 in intensive-dose vs moderate dose trials). INTERPRETATION: The increased risk of type 2 diabetes noted with statins is at least partially explained by HMGCR inhibition. FUNDING: The funding sources are cited at the end of the paper.
- MeSH
- diabetes mellitus 2. typu genetika MeSH
- genetické testování MeSH
- HDL-cholesterol metabolismus MeSH
- hydroxymethylglutaryl-CoA-reduktasy genetika MeSH
- index tělesné hmotnosti MeSH
- jednonukleotidový polymorfismus genetika MeSH
- LDL-cholesterol metabolismus MeSH
- lidé středního věku MeSH
- lidé MeSH
- randomizované kontrolované studie jako téma MeSH
- rizikové faktory MeSH
- senioři MeSH
- statiny škodlivé účinky MeSH
- tělesná hmotnost genetika MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
BACKGROUND: We characterised the phenotypic consequence of genetic variation at the PCSK9 locus and compared findings with recent trials of pharmacological inhibitors of PCSK9. METHODS: Published and individual participant level data (300,000+ participants) were combined to construct a weighted PCSK9 gene-centric score (GS). Seventeen randomized placebo controlled PCSK9 inhibitor trials were included, providing data on 79,578 participants. Results were scaled to a one mmol/L lower LDL-C concentration. RESULTS: The PCSK9 GS (comprising 4 SNPs) associations with plasma lipid and apolipoprotein levels were consistent in direction with treatment effects. The GS odds ratio (OR) for myocardial infarction (MI) was 0.53 (95% CI 0.42; 0.68), compared to a PCSK9 inhibitor effect of 0.90 (95% CI 0.86; 0.93). For ischemic stroke ORs were 0.84 (95% CI 0.57; 1.22) for the GS, compared to 0.85 (95% CI 0.78; 0.93) in the drug trials. ORs with type 2 diabetes mellitus (T2DM) were 1.29 (95% CI 1.11; 1.50) for the GS, as compared to 1.00 (95% CI 0.96; 1.04) for incident T2DM in PCSK9 inhibitor trials. No genetic associations were observed for cancer, heart failure, atrial fibrillation, chronic obstructive pulmonary disease, or Alzheimer's disease - outcomes for which large-scale trial data were unavailable. CONCLUSIONS: Genetic variation at the PCSK9 locus recapitulates the effects of therapeutic inhibition of PCSK9 on major blood lipid fractions and MI. While indicating an increased risk of T2DM, no other possible safety concerns were shown; although precision was moderate.
- MeSH
- anticholesteremika škodlivé účinky terapeutické užití MeSH
- biologické markery krev MeSH
- celogenomová asociační studie MeSH
- cévní mozková příhoda epidemiologie prevence a kontrola MeSH
- down regulace MeSH
- dyslipidemie krev farmakoterapie epidemiologie genetika MeSH
- hodnocení rizik MeSH
- infarkt myokardu epidemiologie prevence a kontrola MeSH
- inhibitory serinových proteinas škodlivé účinky terapeutické užití MeSH
- ischemie mozku epidemiologie prevence a kontrola MeSH
- jednonukleotidový polymorfismus * MeSH
- LDL-cholesterol krev MeSH
- lidé MeSH
- PCSK9 inhibitory MeSH
- proproteinkonvertasa subtilisin/kexin typu 9 genetika MeSH
- randomizované kontrolované studie jako téma MeSH
- rizikové faktory MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH