Paper-based
Dotaz
Zobrazit nápovědu
Carbamazepine is an antiepileptic drug with a narrow therapeutic index, which requires an efficient method for blood level monitoring. Finger-prick dried blood spot (DBS) collection is an alternative microsampling technique, which is less invasive than conventional venipuncture. Paper-based molecularly imprinted-interpenetrating polymer networks (MI-IPN) were developed as blood collection devices, which allowed for selective on-spot microextraction of carbamazepine from DBS. A hybrid of homogeneous polystyrene and silica gel polymer was synthesized and coated on a Whatman® Grade 1 filter paper. Proteins and other interferences in the blood samples were eliminated by using the MI-IPN collection devices, and the resulting DBS extracts were suitable for direct injection into the capillary electrophoretic instrument. The lower limit of quantitation of 4 μg/mL in capillary blood was achieved by the sweeping-micellar electrokinetic chromatography method using a KCl-containing matrix, which was sufficient for the therapeutic drug monitoring purposes. Method accuracies were in the range of 88.4 ± 4.5% to 94.5 ± 2.7% with RSD values ≤ 5.1%. The developed paper-based MI-IPN provided superior extraction efficiencies (92.2 ± 2.5%) in comparison with commercially available DBS collection cards, i.e., Whatman® 903 protein saver card (59.8 ± 2.8%) and GenCollect™ 2.0 card (47.2 ± 1.4%). The paper-based MI-IPN devices for DBS collection and on-spot extraction were characterized by simple fabrication, low costs, disposability, and reduction in sample preparation steps, and their further developments might open new perspectives in clinical applications, such as in therapeutic drug monitoring. Graphical abstract.
- MeSH
- antikonvulziva krev izolace a purifikace MeSH
- elektroforéza kapilární metody MeSH
- karbamazepin krev izolace a purifikace MeSH
- lidé MeSH
- mikroextrakce na pevné fázi metody MeSH
- molekulárně imprintované polymery chemie MeSH
- monitorování léčiv MeSH
- odběr vzorku krve metody MeSH
- papír MeSH
- tandemová hmotnostní spektrometrie MeSH
- test suché kapky krve metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
... 1 -- Does \'evidence-based medicine’ simply mean \'reading papers in medical journals’? ... ... 1 -- Why do people sometimes groan when you mention evidence-based medicine? ... ... 164 -- Evaluating papers that describe qualitative research, 168 References, 176 -- Chapter 13 Papers ... ... 205 -- Contents xi -- What does an \'evidence-based organisation’ look like? ... ... 235 Why is ‘evidence-based policymaking’ so hard to achieve? ...
5th ed. xxii, 261 s. : il., tab. ; 22 cm
- MeSH
- klinické zkoušky kontrolované jako téma MeSH
- medicína založená na důkazech MeSH
- Publikační typ
- příručky MeSH
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- lékařství
Objectives: Ordinary electronic health record (EHR) systems have difficulty managing paper-based medical records because digitized paper-based records must be browsed with a viewer other than the main display for the EHR system. Because of this "fragmentation" of electronic and paper information, it is difficult to combine keyboard/ mouse input with handwriting input in a clinical setting. We developed a new EHR system to address this problem. Methods: We revised a commercial EHR system to function as a progress note system that integrates keyboard/ mouse-based electronic records with digitized paper-based records, both of which can be viewed in a page-turning style. In this system all records, including paper-based records, are arranged in relation to the time they were written, even when they were digitized later at a scanning center. These features of the system allow for combined use of handwritten and keyboard/mouse input, without fragmentation. We investigated the impact of the introduction of the first EHR system in the ophthalmology department at our hospital, which had long resisted implementation of an EHR system. Results: The number of ophthalmology outpatients did not significantly decrease after introduction of the system. The ophthalmologists in our hospital accepted the first EHR system without negative reactions, and a gradual transition from handwritten input to keyboard/mouse input was noted. Conclusions: The present system enables users to produce flexible medical documentation, by using both keyboard/mouse and handwriting inputs, without reducing medical efficiency or safety. This is a cost-efficient, true hybrid digital–analog EHR system.
Distance-based detection (DbD) on paper-based microfluidic analytical devices (μPADs) has emerged as a promising, cost-effective, simple, and instrumentation-free assay method. Broadening the applicability of a new way of immobilization of reagent for DbD on μPADs (DμPADs) is presented, employing an ion exchange (IE) interaction of an anionic metallochromic reagent, 2-(5-bromo-2-pyridylazo)-5-[N-n-propyl-N-(3-sulfopropyl)amino]phenol (5-Br-PAPS), on the anion-exchange filter paper. The IE DμPADs demonstrate superiority over standard cellulose filter paper in terms of the degree of reagent immobilization, detection sensitivity, and clear detection endpoints due to the strong retention of 5-Br-PAPS. The study investigated various parameters influencing DbD, including 5-Br-PAPS concentrations (0.25-1 mM), buffer types (acetic acid-Tris, MES), buffer concentrations (20-500 mM), and auxiliary complexing agents (acetic, formic, and glycolic acids). Subsequently, the performance of 17 metals (Ag+, Cd2+, Co2+, Cr3+, Cu2+, Fe2+, Hg2+, La2+, Mn2+, Ni2+, Pb2+, Ti2+, Zn2+, Al3+, As3+, Fe3+, and V4+) was evaluated, with color formation observed for 12 metals. Additionally, the paper surface was examined using SEM and SEM-EDX to verify the suitability of certain areas in the detection channel for reagent immobilization and metal binding. This method demonstrates quantitation limits of metals in the low μg mL-1 range, showing great potential for the rapid screening of toxic metals commonly found in herbal supplements and cosmetics regulated by the Food and Drug Administration (FDA). Thus, it holds promise for enhancing safety and regulatory compliance in product quality assessment. Furthermore, this method offers a cost-effective, environmentally sustainable, and user-friendly approach for the rapid visual quantification of heavy metals for in-field analysis, eliminating the need for complex instrumentation.
- Publikační typ
- časopisecké články MeSH
Acute intoxication incidents due to neurotoxic organophosphate (OP) insecticides are occasionally reported, related either to suicidal attempts or occupational exposure due to the misuse of protective equipment. Among them, chlorpyrifos is a compound related to great controversy, which is still authorized and easily accessible in many countries around the world. However, to screen for its exposure markers, instrumental methods are commonly applied, which cannot enable rapid monitoring at an early stage of an intoxication. Therefore, in this study, a microfluidic paper-based analytical device (μPAD) able to rapidly screen for chlorpyrifos-oxon, the toxic chlorpyrifos metabolite, in human serum was developed and fully validated. The μPAD combines wax-printed butyrylcholinesterase (BChE) paper sensors, a lab-on-a-chip (LOC) prototype injector and a smartphone as the analytical detector. In principle, the wax-printed strips with adsorbed BChE are embedded into LOC injectors able to deliver samples and reagents on-demand. A smartphone reader was used to monitor the color development on the strips providing binary qualitative results. μPAD method performance characteristics were thoroughly evaluated in terms of specificity, detection capability (CCβ) and ruggedness. The developed analytical platform is rapid (results within 10 min), cost-efficient (0.70 €), potentially applicable at the point-of-need and attained a low CCβ (10 μg L-1 in human serum). Finally, μPAD characteristics were critically compared to well-established methods, namely an in-house BChE microplate assay and liquid chromatography tandem mass spectrometry.
- MeSH
- chytrý telefon MeSH
- dursban * MeSH
- laboratoř na čipu MeSH
- lidé MeSH
- mikrofluidika MeSH
- mikrofluidní analytické techniky * MeSH
- papír MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- MeSH
- lékařská praxe založená na důkazech MeSH
- lidé MeSH
- prevence sebevražd MeSH
- sebevražda MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- konsensus - konference MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa MeSH
This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.
- Publikační typ
- časopisecké články MeSH
4th ed. xvii, 238 s, : il. ; 22 cm
- MeSH
- lékařská informatika MeSH
- lékařská praxe založená na důkazech * MeSH
- výzkum MeSH
- žurnalistika lékařská (masmédia) MeSH
- Publikační typ
- příručky MeSH
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- lékařská informatika