BACKGROUND: The presence of ACPA significantly increases the risk of developing RA. Dysregulation of lymphocyte subpopulations was previously described in RA. Our objective was to propose the predictive model for progression to clinical arthritis based on peripheral lymphocyte subsets and ACPA in individuals who are at risk of RA. METHODS: Our study included 207 at-risk individuals defined by the presence of arthralgias and either additional ACPA positivity or meeting the EULAR definition for clinically suspect arthralgia. For the construction of predictive models, 153 individuals with symptom duration ≥12 months who have not yet progressed to arthritis were included. The lymphocyte subsets were evaluated using flow cytometry and anti-CCP using ELISA. RESULTS: Out of all individuals with arthralgia, 41 progressed to arthritis. A logistic regression model with baseline peripheral blood lymphocyte subpopulations and ACPA as predictors was constructed. The resulting predictive model showed that high anti-CCP IgG, higher percentage of CD4+ T cells, and lower percentage of T and NK cells increased the probability of arthritis development. Moreover, the proposed classification decision tree showed that individuals having both high anti-CCP IgG and low NK cells have the highest risk of developing arthritis. CONCLUSIONS: We propose a predictive model based on baseline levels of lymphocyte subpopulations and ACPA to identify individuals with arthralgia with the highest risk of progression to clinical arthritis. The final model includes T cells and NK cells, which are involved in the pathogenesis of RA. This preliminary model requires further validation in larger at-risk cohorts.
- MeSH
- artralgie * imunologie MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- podskupiny lymfocytů * imunologie MeSH
- prediktivní hodnota testů MeSH
- progrese nemoci * MeSH
- protilátky proti citrulinovaným peptidům * krev imunologie MeSH
- revmatoidní artritida * imunologie krev MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system. METHODS: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis. RESULTS: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes). CONCLUSIONS: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.
- MeSH
- delfská metoda MeSH
- dospělí MeSH
- entezopatie diagnostické zobrazování MeSH
- kloub prstu ruky * diagnostické zobrazování patologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- mrtvola MeSH
- odchylka pozorovatele MeSH
- prsty ruky diagnostické zobrazování patologie MeSH
- psoriatická artritida * diagnostické zobrazování MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- studie proveditelnosti MeSH
- stupeň závažnosti nemoci * MeSH
- synovitida diagnostické zobrazování patologie MeSH
- tenosynovitida diagnostické zobrazování MeSH
- ultrasonografie * metody MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH
OBJECTIVE: To assess the construct validity of the novel Outcome Measures in Rheumatology (OMERACT) ultrasound (US) semiquantitative scoring system for morphological lesions in major salivary glands by comparing it with magnetic resonance imaging (MRI) and unstimulated whole salivary flow rates (U-WSFRs) in patients with primary Sjögren syndrome (pSS). METHODS: Nine sonographers applied the OMERACT 0-3 grayscale scoring system for parotid (PGs) and submandibular glands (SMGs) in 11 patients with pSS who also had MRIs performed. These were evaluated by 2 radiologists using a semiquantitative 0-3 scoring system for morphological lesions. The agreement between US and MRI and the association between U-WSFRs and imaging structural lesions was determined. A score ≥ 2 for both US and MRI was defined as gland pathology. RESULTS: The prevalence of US morphological lesions in 11 patients with a score ≥ 2 was 58% for PGs and 76% for SMGs, and 46% and 41% for PGs and SMGs, respectively, for MRI. The agreement between OMERACT US scores and MRI scores was 73-91% (median 82%) in the right PG and 73-91% (median 91%) in the left PG, 55-91% (median 55%) in the right SMG and 55-82% (median 55%) in the left SMG. When relations between the presence of hyposalivation and an US score ≥ 2 were examined, agreement was 91-100% (median 83%) in both PGs and 55-91% (median 67%) in both SMGs. CONCLUSION: There is moderate to strong agreement between the OMERACT US and MRI scores for major salivary glands in patients with pSS. Similar agreement ratios were observed between the higher OMERACT US scores and presence of hyposalivation.
OBJECTIVES: To develop an Outcome Measures in Rheumatology (OMERACT) ultrasonography score for monitoring disease activity in giant cell arteritis (GCA) and evaluate its metric properties. METHODS: The OMERACT Instrument Selection Algorithm was followed. Forty-nine members of the OMERACT ultrasonography large vessel vasculitis working group were invited to seven Delphi rounds. An online reliability exercise was conducted using images of bilateral common temporal arteries, parietal and frontal branches as well as axillary arteries from 16 patients with GCA and 7 controls. Sensitivity to change and convergent construct validity were tested using data from a prospective cohort of patients with new GCA in which ultrasound-based intima-media thickness (IMT) measurements were conducted at weeks 1, 3, 6, 12 and 24. RESULTS: Agreement was obtained (92.7%) for the OMERACT GCA Ultrasonography Score (OGUS), calculated as follows: sum of IMT measured in every segment divided by the rounded cut-off values of IMTs in each segment. The resulting value is then divided by the number of segments available. Thirty-five members conducted the reliability exercise, the interrater intraclass correlation coefficient (ICC) for the OGUS was 0.72-0.84 and the median intrareader ICC was 0.91. The prospective cohort consisted of 52 patients. Sensitivity to change between baseline and each follow-up visit up to week 24 yielded standardised mean differences from -1.19 to -2.16, corresponding to large and very large magnitudes of change, respectively. OGUS correlated moderately with erythrocyte sedimentation rate, C reactive protein and Birmingham Vasculitis Activity Score (corrcoeff 0.37-0.48). CONCLUSION: We developed a provisional OGUS for potential use in clinical trials.
- MeSH
- arteriae temporales diagnostické zobrazování MeSH
- intimomediální šíře tepenné stěny MeSH
- lidé MeSH
- obrovskobuněčná arteritida * diagnostické zobrazování MeSH
- prospektivní studie MeSH
- reprodukovatelnost výsledků MeSH
- ultrasonografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: In the ULTIMATE study with an open label extension, we assessed the long-term effect of secukinumab at tissue level on synovitis and enthesitis, and across all psoriatic arthritis (PsA) manifestations, using both clinical evaluations and power Doppler ultrasonography (PDUS). METHODS: This randomised, placebo-controlled, Phase 3 study (ULTIMATE) included biologic-naïve patients with PsA with active PDUS synovitis and clinical enthesitis, and inadequate response to conventional synthetic disease-modifying antirheumatic drugs. The study consisted of 3 treatment periods; in the first period (baseline to week 12) patients were randomised to receive subcutaneous secukinumab (150 mg or 300 mg according to severity of skin psoriasis) or placebo every week until week 4 and once every 4 weeks up to week 12. In the second period (weeks 12-24) all patients received open-label secukinumab with placebo patients switching to secukinumab (150 mg or 300 mg). The third period (weeks 24-52) was an extended open-label treatment period. The long-term responsiveness of the Global EULAR-OMERACT Synovitis Score (GLOESS), clinical enthesitis and global PDUS-detected enthesitis score (using two candidate definitions of activity) at patient level, together with clinical efficacy across key manifestations of PsA and safety were assessed. RESULTS: Of the 166 patients enrolled, 144 completed week 52. A significant reduction in GLOESS was demonstrated in the secukinumab group vs placebo at week 12, followed by a stable reduction of synovitis until week 52 in the secukinumab group while placebo switchers from week 12 reached a similar level of reduction at week 24 with stability thereafter. Likewise, a significant reduction in the Spondyloarthritis Research Consortium of Canada (SPARCC) enthesitis index was shown in the secukinumab group vs placebo at week 12 with sustained improvement to week 52. Global OMERACT PDUS enthesitis scores were numerically lower in secukinumab vs placebo switchers in the first two treatment periods, with some stability in the third period in both groups. Improvements in clinical responses were also observed across all key domains of PsA up to week 52 in both treatment groups with no new or unexpected safety signals. CONCLUSIONS: ULTIMATE showed consistent improvements in clinically and ultrasound-assessed synovitis and enthesitis and sustained clinical efficacy through week 52 in patients with PsA treated with secukinumab and placebo switched to secukinumab.
- MeSH
- antirevmatika * škodlivé účinky MeSH
- dvojitá slepá metoda MeSH
- entezopatie * diagnostické zobrazování farmakoterapie MeSH
- humanizované monoklonální protilátky škodlivé účinky MeSH
- lidé MeSH
- psoriatická artritida * komplikace diagnostické zobrazování farmakoterapie MeSH
- synovitida * diagnostické zobrazování farmakoterapie chemicky indukované MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky, fáze III MeSH
- randomizované kontrolované studie MeSH
OBJECTIVE: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). METHODS: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. RESULTS: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra- and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra- and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. CONCLUSION: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.
- MeSH
- lidé MeSH
- podčelistní slinná žláza diagnostické zobrazování MeSH
- reprodukovatelnost výsledků MeSH
- Sjögrenův syndrom * diagnostické zobrazování patologie MeSH
- slinné žlázy diagnostické zobrazování patologie MeSH
- ultrasonografie metody MeSH
- zánět patologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
OBJECTIVES: To define chronic ultrasound lesions of the axillary artery (AA) in long-standing giant cell arteritis (GCA) and to evaluate the reliability of the new ultrasound definition in a web-based exercise. METHODS: A structured Delphi, involving an expert panel of the Large Vessel Vasculitis subgroup of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group was carried out. The reliability of the new definition was tested in a 2-round web-based exercise involving 23 experts and using 50 still images each from AA of long-standing and acute GCA patients, as well as 50 images from healthy individuals. RESULTS: The final OMERACT ultrasound definition of chronic changes was based on measurement and appearance of the intima-media complex. The overall reliability of the new definition for chronic ultrasound changes in longstanding GCA of the AA was good to excellent with Light's kappa values of 0.79-0.80 for inter-reader reliability and mean Light's-kappa of 0.88 for intra-reader reliability. The mean inter-rater and intra-rater agreements were 86-87% and 92%, respectively. Good reliabilities were observed comparing the vessels with longstanding versus acute GCA with a mean agreement and kappa values of 81% and 0.63, respectively. CONCLUSION: The new OMERACT ultrasound definition for chronic vasculitis of the AA in GCA revealed a good to excellent inter- and intra-reader reliability in a web-based exercise of experts.
BACKGROUND: To assess the reliability of the consensually agreed US definitions of major salivary gland lesions and the US scoring system for salivary gland assessment in patients with SS. METHODS: Nine experienced sonographers scanned and read the US images of both parotid glands (PGs) and submandibular glands (SMGs) in eight patients with primary and secondary SS in two rounds. A consensually agreed four-grade semi-quantitative scoring was applied in B-mode for morphological lesions: grade 0, normal; grade 1, mild inhomogeneity without anechoic or hypoechoic areas; grade 2, moderate inhomogeneity with focal anechoic or hypoechoic areas; grade 3, severe inhomogeneity with diffuse an- or hypoechoic areas occupying the entire gland or fibrous gland. The presence or absence of typical SS lesions, i.e. the Sjögren's signature, was scored binary. Intra- and interreader reliabilities were computed using weighted and unweighted Cohen's and Light's κ coefficients. RESULTS: The mean prevalence of grades 0-3 in PG were 43, 17, 23 and 31% and 28, 14, 33 and 32% for the SMGs, respectively. The weighted κ for intrareader reliability ranged from 0.44 to 1 for grading and 0.64 to 1 for the Sjögren's signature of PG and 0.59 to 1 and -0.09 to 0.6 for SMGs, respectively. The interreader reliability κ for grading in PG was 0.62 (95% CI 0.47, 0.74) and for Sjögren's signature it was 0.36 (95% CI 0, 0.43); in SMG it was 0.62 (95% CI 0.47, 0.72) and 0.03 (95% CI 0, 0.07) respectively. CONCLUSIONS: The consensually agreed novel US scoring system for major salivary gland lesions showed substantial intra- and interreader reliability in patients with SS. The reliability of the Sjögren's signature was moderate.
- MeSH
- dospělí MeSH
- hodnocení výsledků zdravotní péče MeSH
- lidé středního věku MeSH
- lidé MeSH
- parotis diagnostické zobrazování MeSH
- podčelistní slinná žláza diagnostické zobrazování MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- Sjögrenův syndrom diagnostické zobrazování MeSH
- ultrasonografie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH