Currently, with the knowledge of the role of collateral circulation in the development of cerebral ischaemia, traditional therapeutic windows are being prolonged, with time not being the only criterion. Instead, a more personalised approach is applied to select additional patients who might benefit from active treatment. This review briefly describes the current knowledge of the pathophysiology of the development of early ischaemic changes, the capabilities of MRI to depict such changes, and the basics of the routinely used imaging techniques broadly available for the assessment of individual phases of cerebral ischaemia, and summarises the possible clinical use of routine MR imaging, including patient selection for active treatment and assessment of the outcome on the basis of imaging.
- MeSH
- cerebrální infarkt MeSH
- cévní mozková příhoda * diagnostické zobrazování terapie MeSH
- difuzní magnetická rezonance metody MeSH
- edém mozku * MeSH
- ischemická cévní mozková příhoda * MeSH
- ischemie mozku * diagnostické zobrazování terapie MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
PURPOSE: Infarct lesion volume (ILV) may serve as an imaging biomarker for clinical outcomes in the early post-treatment stage in patients with acute ischemic stroke. The aim of this study was to evaluate the inter- and intra-rater reliability of manual segmentation of ILV on follow-up non-contrast CT (NCCT) scans. METHODS: Fifty patients from the Prove-IT study were randomly selected for this analysis. Three raters manually segmented ILV on 24-h NCCT scans, slice by slice, three times. The reference standard for ILV was generated by the Simultaneous Truth And Performance Level estimation (STAPLE) algorithm. Intra- and inter-rater reliability was evaluated, using metrics of intraclass correlation coefficient (ICC) regarding lesion volume and the Dice similarity coefficient (DSC). RESULTS: Median age of the 50 subjects included was 74.5 years (interquartile range [IQR] 67-80), 54% were women, median baseline National Institutes of Health Stroke Scale was 18 (IQR 11-22), median baseline ASPECTS was 9 (IQR 6-10). The mean reference standard ILV was 92.5 ml (standard deviation (SD) ± 100.9 ml). The manually segmented ILV ranged from 88.2 ± 91.5 to 135.5 ± 119.9 ml (means referring to the variation between readers, SD within readers). Inter-rater ICC was 0.83 (95%CI: 0.76-0.88); intra-rater ICC ranged from 0.85 (95%CI: 0.72-0.92) to 0.95 (95%CI: 0.91-0.97). The mean DSC among the three readers ranged from 65.5 ± 22.9 to 76.4 ± 17.1% and the mean overall DSC was 72.8 ± 23.0%. CONCLUSION: Manual ILV measurements on follow-up CT scans are reliable to measure the radiological outcome despite some variability.
- MeSH
- algoritmy MeSH
- cévní mozková příhoda * diagnostické zobrazování MeSH
- ischemická cévní mozková příhoda * MeSH
- lidé MeSH
- počítačová rentgenová tomografie metody MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Medium vessel occlusions (MeVOs) can be challenging to detect on imaging. Multiphase computed tomography angiography (mCTA) has been shown to improve large vessel occlusion (LVO) detection and endovascular treatment (EVT) selection. The aims of this study were to determine if mCTA-derived tissue maps can (1) accurately detect MeVOs and (2) predict infarction on 24-h follow-up imaging with comparable accuracy to CT perfusion (CTP). METHODS: Two readers assessed mCTA tissue maps of 116 ischemic stroke patients (58 MeVOs, 58 non-MeVOs) and determined by consensus: (1) MeVO (yes/no) and (2) occlusion site, blinded to clinical or imaging data. Sensitivity, specificity, and area under the curve (AUC) for MeVO detection were estimated in comparison to reference standards of (1) expert readings of baseline mCTA and (2) CTP maps. Volumetric and spatial agreement between mCTA- and CTP-predicted infarcts was assessed using concordance/intraclass correlation and Dice coefficients. Interrater agreement for MeVO detection on mCTA tissue maps was estimated with Cohen's kappa. RESULTS: MeVO detection from mCTA-derived tissue maps had a sensitivity of 91% (95% CI: 80-97), specificity of 82% (95% CI: 70-90), and AUC of 0.87 (95% CI: 0.80-0.93) compared to expert reads of baseline mCTA. Interrater reliability was good (0.72, 95% CI: 0.60-0.85). Compared to CTP maps, sensitivity was 87% (95% CI: 75-95), specificity was 78% (95%CI: 65-88), and AUC was 0.83 (95% CI: 0.76-0.90). The mean difference between mCTA- and CTP-predicted final infarct volume was 4.8 mL (limits of agreement: - 58.5 to 68.1) with a Dice coefficient of 33.5%. CONCLUSION: mCTA tissue maps can be used to reliably detect MeVO stroke and predict tissue fate.
- MeSH
- cévní mozková příhoda * diagnostické zobrazování terapie MeSH
- CT angiografie metody MeSH
- cytidintrifosfát MeSH
- ischemie mozku * terapie MeSH
- lidé MeSH
- mozková angiografie metody MeSH
- počítačová rentgenová tomografie metody MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: CT angiography (CTA) is the imaging standard for large vessel occlusion (LVO) detection in patients with acute ischemic stroke. StrokeSENS LVO is an automated tool that utilizes a machine learning algorithm to identify anterior large vessel occlusions (LVO) on CTA. The aim of this study was to test the algorithm's performance in LVO detection in an independent dataset. METHODS: A total of 400 studies (217 LVO, 183 other/no occlusion) read by expert consensus were used for retrospective analysis. The LVO was defined as intracranial internal carotid artery (ICA) occlusion and M1 middle cerebral artery (MCA) occlusion. Software performance in detecting anterior LVO was evaluated using receiver operator characteristics (ROC) analysis, reporting area under the curve (AUC), sensitivity, and specificity. Subgroup analyses were performed to evaluate if performance in detecting LVO differed by subgroups, namely M1 MCA and ICA occlusion sites, and in data stratified by patient age, sex, and CTA acquisition characteristics (slice thickness, kilovoltage tube peak, and scanner manufacturer). RESULTS: AUC, sensitivity, and specificity overall were as follows: 0.939, 0.894, and 0.874, respectively, in the full cohort; 0.927, 0.857, and 0.874, respectively, in the ICA occlusion cohort; 0.945, 0.914, and 0.874, respectively, in the M1 MCA occlusion cohort. Performance did not differ significantly by patient age, sex, or CTA acquisition characteristics. CONCLUSION: The StrokeSENS LVO machine learning algorithm detects anterior LVO with high accuracy from a range of scans in a large dataset.
- MeSH
- arteriální okluzní nemoci * MeSH
- cévní mozková příhoda * diagnostické zobrazování MeSH
- CT angiografie metody MeSH
- infarkt arteria cerebri media diagnostické zobrazování MeSH
- ischemická cévní mozková příhoda * MeSH
- ischemie mozku * MeSH
- lidé MeSH
- retrospektivní studie MeSH
- software MeSH
- strojové učení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
PURPOSE: Neuroimaging pipelines have long been known to generate mildly differing results depending on various factors, including software version. While considered generally acceptable and within the margin of reasonable error, little is known about their effect in common research scenarios such as inter-group comparisons between healthy controls and various pathological conditions. The aim of the presented study was to explore the differences in the inferences and statistical significances in a model situation comparing volumetric parameters between healthy controls and type 1 diabetes patients using various FreeSurfer versions. METHODS: T1- and T2-weighted structural scans of healthy controls and type 1 diabetes patients were processed with FreeSurfer 5.3, FreeSurfer 5.3 HCP, FreeSurfer 6.0 and FreeSurfer 7.1, followed by inter-group statistical comparison using outputs of individual FreeSurfer versions. RESULTS: Worryingly, FreeSurfer 5.3 detected both cortical and subcortical volume differences out of the preselected regions of interest, but newer versions such as FreeSurfer 5.3 HCP and FreeSurfer 6.0 reported only subcortical differences of lower magnitude and FreeSurfer 7.1 failed to find any statistically significant inter-group differences. CONCLUSION: Since group averages of individual FreeSurfer versions closely matched, in keeping with previous literature, the main origin of this disparity seemed to lie in substantially higher within-group variability in the model pathological condition. Ergo, until validation in common research scenarios as case-control comparison studies is included into the development process of new software suites, confirmatory analyses utilising a similar software based on analogous, but not fully equivalent principles, might be considered as supplement to careful quality control.
PURPOSE: To compare the association of different measures of intracranial thrombus permeability on non-contrast computerized tomography (NCCT) and computed tomography angiography (CTA) with recanalization with or without intravenous alteplase. METHODS: Patients with anterior circulation occlusion from the INTERRSeCT study were included. Thrombus permeability was measured on non-contrast CT and CTA using the following methods: [1] automated method, mean attenuation increase on co-registered thin (< 2.5 mm) CTA/NCCT; [2] semi-automated method, maximum attenuation increase on non-registered CTA/NCCT (ΔHUmax); [3] manual method, maximum attenuation on CTA (HUmax); and [4] visual method, residual flow grade. Primary outcome was recanalization with intravenous alteplase on the revised AOL scale (2b/3). Regression models were compared using C-statistic, Akaike (AIC), and Bayesian information criterion (BIC). RESULTS: Four hundred eighty patients were included in this analysis. Statistical models using methods 2, 3, and 4 were similar in their ability to discriminate recanalizers from non-recanalizers (C-statistic 0.667, 0.683, and 0.634, respectively); method 3 had the least information loss (AIC = 483.8; BIC = 492.2). A HUmax ≥ 89 measured with method 3 provided optimal sensitivity and specificity in discriminating recanalizers from non-recanalizers [recanalization 55.4% (95%CI 46.2-64.6) when HUmax > 89 vs. 16.8% (95%CI 13.0-20.6) when HUmax ≤ 89]. In sensitivity analyses restricted to patients with co-registered CTA/NCCT (n = 88), methods 1-4 predicted recanalization similarly (C-statistic 0.641, 0.688, 0.640, 0.648, respectively) with Method 2 having the least information loss (AIC 104.8, BIC 109.8). CONCLUSION: Simple methods that measure thrombus permeability are as reliable as complex image processing methods in discriminating recanalizers from non-recanalizers.
- MeSH
- Bayesova věta MeSH
- CT angiografie metody MeSH
- fibrinolytika terapeutické užití MeSH
- intrakraniální trombóza diagnostické zobrazování farmakoterapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- počítačová rentgenová tomografie metody MeSH
- prospektivní studie MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tkáňový aktivátor plazminogenu terapeutické užití MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- srovnávací studie MeSH
Brain abscess caused by Listeria monocytogenes (LM) is a rare, yet serious condition with high mortality if not recognized and treated timely. We present a series of three cases of LM brain abscesses and describe their characteristic radiological appearances which can be considered very typical. LM abscesses frequently present as markedly irregular formations, revealing characteristic worm-like tubular pattern of chaotic curvilinear arrangement. Knowledge of this imaging pattern can be very helpful in early recognition of LM abscesses whose initial differential diagnosis can often be misleading initially.
- MeSH
- absces mozku diagnostické zobrazování farmakoterapie mikrobiologie MeSH
- diferenciální diagnóza MeSH
- dospělí MeSH
- fatální výsledek MeSH
- kombinovaná farmakoterapie MeSH
- kontrastní látky MeSH
- lidé středního věku MeSH
- lidé MeSH
- listeriové infekce diagnostické zobrazování farmakoterapie MeSH
- magnetická rezonanční tomografie * MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
PURPOSE: Ischemic lesion volume (ILV) is an important radiological predictor of functional outcome in patients with anterior circulation stroke. Our aim was to assess the agreement between automated ILV measurements on NCCT using the Brainomix software and manual ILV measurements on diffusion-weighted imaging (DWI). METHODS: This was a prospective single-center observational study of patients with CT angiography (CTA) proven anterior circulation occlusion treated with endovascular thrombectomy (May 2018 to May 2019). NCCT ILV was measured automatically by the Brainomix software. DWI ILV was measured manually. The McNemar's test was used to test sensitivity and specificity. The Somer's delta was used to test the differences between concordant and discordant ASPECTS regions. The Bland-Altman plot was calculated to compare the differences between Brainomix and DWI ILVs. RESULTS: Forty-five patients were included. Median Brainomix ILV was 23 ml (interquartile range [IQR], 15-39 ml), and median DWI ILV was 11.5 ml (IQR, 7-32 ml) in the TICI 2b-3 group. In the TICI 0-2a, the NCCT ILV was 39 ml (IQR, 18-62 ml) and DWI ILV was 30 (IQR, 11-105 ml). The DWI ILVs in patients with good clinical outcome (mRS 0-2) was significantly lower compared with patients with mRS ≥ 3 (10 mL vs 59 mL, p = 0.002). Similar trend was observed for Brainomix ILV measurements (21 mL vs 39 mL, p = 0.012). There was a high correlation and accuracy in the detection of follow-up ischemic changes in particular ASPECTS regions. CONCLUSION: NCCT ILV measured automatically by the Brainomix software might be considered a valuable radiological outcome measure.
- MeSH
- CT angiografie metody MeSH
- difuzní magnetická rezonance MeSH
- ischemická cévní mozková příhoda diagnostické zobrazování chirurgie MeSH
- lidé MeSH
- mozková angiografie metody MeSH
- prospektivní studie MeSH
- rentgenový obraz - interpretace počítačová metody MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- software MeSH
- strojové učení * MeSH
- trombektomie * MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- pozorovací studie MeSH
PURPOSE: The artery of Adamkiewicz (AKA) provides the major blood supply to the anterior thoracolumbar spinal cord and iatrogenic injury or inadequate reconstruction of this vessel during vascular and endovascular surgery can result in postoperative neurological deficit due to spinal cord ischemia. The aim of this study was to provide comprehensive data on the prevalence and anatomical characteristics of the AKA. METHODS: An extensive search was conducted through the major electronic databases to identify eligible articles. Data extracted included study type, prevalence of the AKA, gender, number of AKA per patient, laterality, origin based on vertebral level, side of origin, morphometric data, and ethnicity subgroups. RESULTS: A total of 60 studies (n = 5437 subjects) were included in the meta-analysis. Our main findings revealed that the AKA was present in 84.6% of the population, and patients most frequently had a single AKA (87.4%) on the left side (76.6%) originating between T8 and L1 (89%). CONCLUSION: As an AKA is present in the majority of the population, caution should be taken during vascular and endovascular surgical procedures to avoid injury or ensure proper reconstruction. All surgeons operating in the thoracolumbar spinal cord should have a thorough understanding of the anatomical characteristics and surgical implications of an AKA.
- MeSH
- arterie anatomie a histologie MeSH
- bederní obratle MeSH
- hrudní obratle MeSH
- lidé MeSH
- mícha krevní zásobení MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- systematický přehled MeSH