254 s.
- MeSH
- Air Pollution MeSH
- Conspectus
- Veřejné zdraví a hygiena
- NML Fields
- environmentální vědy
With current science and policy needs, more attention is being given to expanding and improving air sampling of semivolatile organic contaminants (SVOCs). However, a wide range of techniques and configurations are currently used (active and passive samplers, different deployment times, different sorbents, etc.) and as the SVOC community looks to assess air measurements on a global scale, questions of comparability arise. We review current air sampling techniques, with a focus on sampling artifacts that can lead to uncertainties or biases in reported concentrations, in particular breakthrough, degradation, meteorological influences, and assumptions regarding passive sampling. From this assessment, we estimate the bias introduced for SVOC concentrations from all factors. Due to the effects of breakthrough, degradation, particle fractions and sampler uptake periods, some current passive and active sampler configurations may underestimate certain SVOCs by 30-95%. We then recommend future study design, appropriateness of sampler types for different study goals, and finally, how the SVOC community should move forward in both research and monitoring to best achieve comparability and consistency in air measurements.
The effects of sampling artifacts are often not fully considered in the design of air monitoring with active air samplers. Semivolatile organic contaminants (SVOCs) are particularly vulnerable to a range of sampling artifacts because of their wide range of gas-particle partitioning and degradation rates, and these can lead to erroneous measurements of air concentrations and a lack of comparability between sites with different environmental and sampling conditions. This study used specially adapted filter-sorbent sampling trains in three types of active air samplers to investigate breakthrough of SVOCs, and the possibility of other sampling artifacts. Breakthrough volumes were experimentally determined for a range of polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polybrominated diphenyl ethers (PBDEs) in sampling volumes from 300 to 10,000 m(3), and sampling durations of 1-7 days. In parallel, breakthrough was estimated based on theoretical sorbent-vapor pressure relationships. The comparison of measured and theoretical determinations of breakthrough demonstrated good agreement between experimental and estimated breakthrough volumes, and showed that theoretical breakthrough estimates should be used when developing air monitoring protocols. Significant breakthrough in active air samplers occurred for compounds with vapor pressure >0.5 Pa at volumes <700 m(3). Sample volumes between 700 and 10,000 m(3) may lead to breakthrough for compounds with vapor pressures between 0.005 and 0.5 Pa. Breakthrough is largely driven by sample volume and compound volatility (therefore indirectly by temperature) and is independent of sampler type. The presence of significant breakthrough at "typical" sampling conditions is relevant for air monitoring networks, and may lead to under-reporting of more volatile SVOCs.
Increasing use of current-use pesticides (CUPs) in Africa raises environmental and public health concerns. But there is a large uncertainty about their occurrence and the composition of pesticide mixtures on this continent. This paper investigates the presence of 27 CUPs in air across 20 sampling sites in Africa. 166 passive air samples, consisting of polyurethane foam (PUF), were collected in 12 African countries between 2010 and 2018. Samples were extracted with methanol and analyzed via high-performance liquid chromatography coupled with tandem mass spectrometry. The detection frequencies of CUPs per site were compared to land use patterns and sampling years, while their similarities were assessed using hierarchical cluster analysis. Overall, 24 CUPs were detected at least once. In 93% of all samples, at least one CUP was detected, while 78% of the samples had mixtures of two or more CUPs (median 3, interquartile range 5). Atrazine and chlorpyrifos were detected in 19 out of 20 sampling sites. Carbaryl, metazachlor, simazine, tebuconazole and terbuthylazine had the highest detection frequencies at sampling sites dominated by croplands. Across all the sampling years, 16 CUPs were present. Seven CUPs were newly detected from 2016 onwards (azinfos-methyl, dimetachlor, chlorsulfuron, chlortoluron, isoproturon, prochloraz and pyrazon), while metamitron was only present before 2012. Sites within a radius of about 200 km showed similarities in detected CUP mixtures across all samples. Our results show the presence of CUP mixtures across multiple agricultural and urban locations in Africa which requires further investigation of related environmental and human health risks.
- MeSH
- Atrazine analysis MeSH
- Chlorpyrifos analysis MeSH
- Air Pollutants analysis MeSH
- Humans MeSH
- Environmental Monitoring * MeSH
- Pesticides analysis MeSH
- Polyurethanes MeSH
- Agriculture MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Africa MeSH