Acta oto-laryngologica, ISSN 0365-5237 suppl. 182, 1963
93 s. : il., tab., grafy ; 26 cm
Statins have revolutionized the treatment of hypercholesterolemia due to their ability to inhibit cholesterol biosynthesis. Their immunomodulatory and anti-inflammatory effects and positive effects on the treatment of atherosclerosis and its complications are well known. Here, we describe the effects of statins on the treatment of presbycusis in C57BL/6J mice. In this strain with accelerated aging, we demonstrate that animals treated with atorvastatin (10mg/kg per day in chow diet) for 2 months showed larger amplitudes of distortion product otoacoustic emissions (DPOAE) than did the non-treated control group. This finding indicates a better survival of outer hair cell function in the inner ear of C57BL/6J mice. The observed decreased expression of intercellular and vascular adhesion molecules in the aortic wall of atorvastatin-treated animals suggests that reducing endothelial inflammatory effects may contribute to the positive effect of atorvastatin on the amplitudes of DPOAE by influencing the blood supply to the inner ear. No such beneficial effect of statins was found in apoE(-/-) mice treated with atorvastatin under the same conditions. Our results suggest that statins could also slow down the age-related deterioration of hearing in man.
- MeSH
- Acoustic Stimulation MeSH
- Apolipoproteins E deficiency MeSH
- Time Factors MeSH
- Gene Expression genetics MeSH
- Financing, Organized MeSH
- Heptanoic Acids therapeutic use MeSH
- Intercellular Adhesion Molecule-1 metabolism MeSH
- Mice, Inbred C57BL MeSH
- Mice, Knockout MeSH
- Mice MeSH
- Otoacoustic Emissions, Spontaneous drug effects MeSH
- Food, Formulated MeSH
- Presbycusis diet therapy pathology prevention & control MeSH
- Pyrroles therapeutic use MeSH
- Receptors, Vasopressin metabolism MeSH
- Auditory Threshold physiology drug effects MeSH
- Aging MeSH
- Hydroxymethylglutaryl-CoA Reductase Inhibitors therapeutic use MeSH
- Ear, Inner physiopathology MeSH
- Dose-Response Relationship, Radiation MeSH
- Animals MeSH
- Check Tag
- Mice MeSH
- Animals MeSH
Klinické využití otoakustických emisí jako indikátoru kochleární funkce je do značné míry omezeno závislostí na stavu středouší. Dobrá transdukční funkce středního ucha je nezbytnou podmínkou pro detekovatelnost otoakustických emisí v zevním zvukovodu. Autoři se rozhodli vyhodnotit nálezy otoakustických emisí u 60 uší (52 osob) po různých typech ušních operací. Podmínkou zařazení do studie byl práh vzdušného vedení na frekvencích 0,5 - 4,0 kHz < 25dB HL a vzdušně-kostní rozdíl (A-B gap) < 10 dB. TEOAE byly výbavné u 17 z 20 uší po tympanostomii. Detekovatelnost TEOAE nebyla závislá na časovém intervalu po inzerci gromety. Na rozdíl od TEOAE byly DPOAE obvykle nevýbavné nebo neměřitelné nebo měly velmi malou amplitudu. TE i DPOAE byly výbavné u tří ze 13 uší po fasciální retromyringické myringoplastice, v jednom případě byly výbavné pouze DPOAE. U zbylých devíti uší byly EOAE nevýbavné. TE i DPOAE nebyly výbavné na uších po inzerci hydroxylapatitového TORPu, PORPu, ani po rekonstrukci inkudosta- pediálního skloubení ionomerním cementem. Evokované otoakustické emise byly detekovatelné pouze na jednom z 19 uší operovaných pro otosklerózu (stapedoplastika podle Schuknechta). Naopak jasně pozitivní emise byly získány na dvou uších po antromastoidektomii pro akutní mastoiditidu a na dvou uších po chirurgickém odstranění exostóz zevního zvukovodu. Popsaná pozorování vedou k závěru, že absence EOAE po středoušní mikrochirurgii je pravděpodobně způsobena drobnými změnami ve středouší, nikoli poškozením vnitřního ucha. EOAE nejsou vhodné k vyšetření kochleární funkce po tympanoplastických operacích. Lze je doporučit pouze u stavů po tympanostomii, za výhodnější test u uší s grometami lze považovat TEOAE. U lehkých nedoslýcha- vostí mohou otoakustické emise podstatným způsobem přispět k odlišení převodního a percepčního typu poruchy.
The clinical application of otoacoustic emissions as an indicator of cochlear function is limited to a considerable extent by the state of the middle ear. Adequate transduction function of the middle ear is an essential prerequisite for detection of otoacoustic emissions in the external auditory meatus. The authors decided to evaluate otoacustic emissions in 60 ears (52 subjects) after various types of ear surgery. The condition for inclusion in the investigation was a threshold of air conduction at frequencies of 0.5 - 4.0 kHz < 25 dB and aie-bone gap Ł 10 dB. TEOAE were produced in 17 of 20 ears after tympanostomy. The detectability of TEOAE did not depend on the time interval after insertion of the grommet. Contrary to TEOAE, DPOAE as a rule were negative or unmeasured or had a very low amplitude. TE and DPOAE could be elicited in three of 134 ears after fascial retromyringal myringoplasty, in one case only DPOAE could be detected. In the remaining nine ears EOAE could not be evoked. TE and DPOAE were absent in ears after insertion of hydroxylapatite TORP, PORP as well as after reconstruction of incudostapedial articulation by means of ionomeric cement. Evoked otoacoustic emissions were detectable only in one of 19 ears operated on account of otosclerosis (stapedoplastiy according to Schuknecht). Conversely, clearly positive emissions were obtained in two ears after antromastoidectomy on account of acute mastoiditis and in two ears after surgicals removal of exostoses of the external auditory meatus. The described obervations lead to the conclusion that the absence of EOAE after middle ear microsurgery is probably due to minor changes in the middle ear and not damage of the inner ear. EOAE are not suitable for examination of cochlear function after tympanoplastic operations. They can be recommended only in conditions after tympanostomy. A more suitable test in ears with grommets is TEOAE. In mild deafness otoacoustic emissions may contribute in a substantial way to differentiation of conductive and perception types of the disorder.
Na klinice otorinolaryngologie a chirurgie hlavy a krku 1. LF UK FN Motol bylvypracován elektronický archivační systém k uchovávání a dalšímu zpracování dat u pacientů porekonstrukčních operacích středního ucha. Databáze obsahuje kromě identifikačních dat operova-ného i poznámky anamnestické, operační a dispenzarizační a zaznamenává i příslušná audiomet-rická měření. Databáze slouží jako archiv a východisko při dalším zpracování dat a testováníhypotéz.
An electronic archive system has been realized in the Department of otolaryngology, head and neck surgery of the First Medical Faculty, Faculty Hospital Motol, Prague. It serves for data collection and further processing in patients after reconstructive meddle-ear surgery. The database comprises of patient's identification data, history, data from surgery and follow-up, audiometric parameters. The aim of the product is to serve as an archive and a starting point in data processing and hypotheses testing.
- MeSH
- Medical Records Systems, Computerized trends MeSH
- Humans MeSH
- Ear, Middle surgery MeSH
- Tympanoplasty contraindications trends MeSH
- Check Tag
- Humans MeSH
- Publication type
- Database MeSH
V souboru 39 nemocných s epitympanálním chronickým zánětem byly sledovány výsledkypředoperačního tympanometrického vyšetření testy dle Valsalva a Toynbee, zastoupení jednotli-vých druhů sanačně rekonstrukčních výkonů a peroperační nálezy. Pro stanovení funkčního vý-sledku byly srovnávány předoperační a pooperační audiometrické nálezy.Šetření prokázalo v rámci systematického tympanometrického předoperačního vyšetření u epitym-panálních otitid v 74 % tubární obstrukci. Přes tento nepříznivý funkční nález byla tympanoosiku-loplastika provedená v jedné době úspěšná ve smyslu zlepšení nebo zachování prahu sluchu napředoperační úrovni u 73 % případů. Vysoké procento tubární obstrukce při předoperačním vyšet-ření nekoreluje s klinickým nálezem a ukazuje se u epitympanálních zánětů jako nepřesné. Z prog-nostického hlediska mají největší šanci na úspěch epitympanální otitidy s cholesteatomemi u tubárních obstrukcí, nejmenší šance na úspěch je u hnisavých epitympanálních otitid. Vykonánírekonstrukční operace po sanačním výkonu u epitympanálních zánětů v jedné době i při tubárníobstrukci je účelné.
In a group of 39 patients with epitympanic chronic inflammation the results of the preoperative tympanometric examination by Valsalva™s and Toynbee™s tests were followed up with regard to the ratio of different types of sanitary reconstruction operations and peroperative findings. For assessment of the functional results the authors compared the preoperative and postoperative audiometric findings. The investigation revealed within the framework of systematic tympanometric preoperative exa- mination in epitympanic otitis 74% tubal obstructions. Despite this adverse functional finding the tympanoossiculoplasty was performed in one stage and was successful as far as improvement or preservation of the auditory threshold at the preoperative level in 73% of the patients. A large percentage of tubal obstructions during the preoperative examination does not correlate with the clinical finding and proves inaccurate in epitympanic inflammations. From the prognostic aspect epitympanic otitis with a cholesteatoma and in tubal obstructions have the greatest chance while the chance is lowest in suppurative epitympanic otitis. It is expedient to complete the reconstruction operation after sanitation in epitympanic inflammations in one stage also in case of tubal obstruc- tion.
- MeSH
- Acoustic Impedance Tests MeSH
- Child MeSH
- Adult MeSH
- Eustachian Tube physiology pathology MeSH
- Middle Aged MeSH
- Humans MeSH
- Otitis etiology surgery MeSH
- Ear, Middle surgery MeSH
- Tympanoplasty methods MeSH
- Inflammation etiology MeSH
- Check Tag
- Child MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
Acta oto-laryngologica, ISSN 0365-5237 suppl. 451, 1988
35 s. : il., grafy ; 26 cm