Reference electrode
Dotaz
Zobrazit nápovědu
The potentials of electrochemical processes in ideal aqueous media are related to the potential of a normal hydrogen electrode (NHE). However, in non-ideal media, the potentials of a metallocene redox couple are used as a reference. Such measurements with free metallocene in solution are complicated by adsorption and mass transport phenomena and solvation effects. Herein, a platinum electrode with an anchored ferrocene moiety (Pt,Fc) was used for cyclic voltammetric measurements of the potential of ferrocene/ferrocenium (Fc/Fc+) redox transformation in not only non-aqueous but, for the first time, aqueous solutions as well. This enabled us to eliminate the aforementioned problems associated with the application of free metallocene molecules in solution and, thus, to relate the midpoint potential (Epm) of the Fc/Fc+ redox couple to a NHE. After elimination of the liquid junction potential in an aqueous 0.1 M KCl solution at 25 °C, the average intraday Epm value obtained with freshly prepared Pt,Fc electrodes was found to be 0.312 ± 0.008 V versus the secondary Ag|AgCl electrode. The Pt,Fc electrode can be applied for the standardization of electrochemical measurements and investigation of solvation phenomena at interfaces in non-ideal media.
- Publikační typ
- časopisecké články MeSH
PURPOSE: The DTL fibre electrode is commonly used to record the electric potentials elicited by stimulation of the retina. Two positions are commonly used: it is placed either on the cornea along the lower lid or in the conjunctival fornix. The PERG and OPs have previously been examined and compared under both conditions. The aim of this study was to examine the ERG, flicker response and on-off responses with differing electrode positions. METHODS: Before recruitment, all subjects underwent an ophthalmological examination. We enrolled 13 normal control subjects into the study aged 13-64 years, all with a visual acuity of ≥1.0. We recorded scotopic and photopic ERGs, flicker and on-off responses, for both electrode positions. On the first day, one eye had the electrode placed on the cornea along the lower lid and the other eye had it positioned in the conjunctival sac. On a second day, the recordings were repeated with the alternative electrode placements. RESULTS: ERG, on-off and flicker responses were all smaller by between 20 and 25% when the DTL electrode was positioned in the conjunctival sac, compared to when it was positioned on the cornea, as did the scatter in the data points. This indicates that there is no advantage clinically for one or the other placement. CONCLUSIONS: Our results confirm other reports examining the effect of electrode position on electrophysiological potentials. When recording with the DTL electrode, it is important to ensure that it is placed at the same position in repeat recordings or in multicentre trials and that it is stable and does not move during recording.
- MeSH
- dospělí MeSH
- elektrofyziologie metody MeSH
- elektroretinografie metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- mikroelektrody * MeSH
- mladiství MeSH
- mladý dospělý MeSH
- retina fyziologie MeSH
- rohovka fyziologie MeSH
- studie případů a kontrol MeSH
- světelná stimulace metody MeSH
- zraková ostrost MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Annals of otology, rhinology & laryngology, ISSN 0096-8056 Supplement Vol. 107. 175
36 s. : il. ; 30 cm
Significant improvements in the voltammetric determination of β-carotene (BCA) have been achieved, mainly by the replacement of toxic dichloromethane with acetone and using non-mercury electrode. The respective procedure is based on anodic oxidation of BCA at a gold electrode in the disc configuration, when using square-wave voltammetry in pure acetone (99.8%) with 0.1 mol L-1 LiClO4 as the supporting electrolyte. The method comprises extraction of the analyte from the sample with acetone, thus avoiding the usually used highly toxic solvents. Analytically, it can be characterized by a linear range from 6.0 × 10-6 to 5.9 × 10-4 mol L-1 with regression equation Ipa = 0.0184c -0.1631 and correlation coefficient, R2 = 0.9998, limits of detection and quantification LOD = 1.6 × 10-6 mol L-1 and LOQ = 5.4 × 10-6 mol L-1, respectively; both being obtained at a potential step of 5 mV, with the pulse amplitude of 25 mV, and a frequency of 80 Hz. After optimization, the method was evaluated in series of analyses; namely, with two samples of vegetables and two pharmaceutical preparations (capsules), when the results could be compared to those of a reference spectrophotometric method. Due to a simple instrumentation, including sample preparation, the voltammetric method for the determination of BCA can be recommended as a quick screening assay in food and pharmaceutical analysis.
- MeSH
- beta-karoten MeSH
- elektrochemie MeSH
- elektrody MeSH
- tobolky MeSH
- zelenina * MeSH
- zlato * MeSH
- Publikační typ
- časopisecké články MeSH
Nedostatečná úroveň analytické kvality měření chloridů v séru, plasmě a krvi rutinními laboratorními metodami ISE je prokázána výsledky externího hodnocení kvality – EHK (čtyř programů), vyhodnocením interferencí bikarbonátů a dlouhodobým sledováním výsledků pacientů v asi 130 laboratořích v různých zemích. Základním problémem jsou vysoké rozdíly mezi testovacími soupravami nebo mezi přístroji různých výrobců. Příčinou je nedostatečná selektivita a stabilita signálu řady rutinně používaných chloridových elektrod, důsledkem je nízká diagnostická efektivita výsledků měření, kterou lze demonstrovat pomocí extrémně vysokých hodnot kritických referenčních změn (RCV). Přitom již řadu let existuje funkční referenční systém měření chloridů i metrologická návaznost kalibrace rutinních metod na něj.
Insufficient level of analytical quality of chloride determination in blood serum and plasma using routine ISE methods has been demonstrated by the external quality assessment (EQA), by assessment of bicarbonate interference, and longterm follow-up of patient results in approx. One hundred thirty laboratories in several countries. The principal issues are considerable differences between test kits and instruments of various producers. The cause is insufficient selectivity and signal stability of many commonly used chloride electrodes, leading to low diagnostic effectivity of measurement results. This can be demonstrated by extremely high reference change values (RCV). Paradoxically, for many years there was a functional reference system of chloride measurement and metrological traceability of routine methods calibration.
Cíl. Prezentovat prvé zkušenosti s užitím MR kompatibilního kardiostimulátoru EnRhythm MRI SureScan s MR kompatibilními elektrodami CapSureFix MRI Materiál, metodika a výsledky. MR kompatibilní kardiostimulátor EnRhythm MRI SureScan s MR kompatibilními elektrodami CapSureFix MRI byl v Nemocnici Na Homolce v rámci klinického zkoušení implantován 52 pacientům, z nichž na základě randomizace 25 podstoupilo MR vyšetření. Tento typ kardiostimulátoru je MR kompatibilní jen za přesně definovaných podmínek na uzavřeném MR systému 1,5 Tesla nejméně 6 týdnů po implantaci. Před uložením pacienta do MR přístroje je nezbytné nastavení stimulátoru do MR kompatibilního modu kardiologem nebo technikem. Po MR vyšetření se provádí zpětné nastavení a kontrola stimulátoru. Izocentrum vyšetření nesmí být uloženo mezi C1 a Th 12. Průměrná specifická míra absorpce (SAR) pro celé tělo smí být maximálně 2,0 W/kg, v oblasti hlavy maximálně 3,2 W/kg, slew rate MR přístroje maximálně 200 T/m/s. Závěr. Doporučujeme ověření správnosti stimulátoru i elektrod pomocí RTG snímku hrudníku. Pacient musí být v průběhu vyšetření monitorován stran vitálních funkcí (EKG nebo pulzní oxymetr nebo monitorace krevního tlaku), nesmí se vyšetřovat v poloze na boku.
Aim. To present first results and experience with the use of a MR-compatible cardiac pacemaker EnRhythm MRI SureScan with MR compatible electrodes CapSureFix MRI. Material, methods and results. A MRcompatible cardiac pacemaker EnRhythm MRI SureScan with MR compatible electrodes CapSureFix MRI was implanted in 52 patients in a clinical study at Na Homolce Hospital. Twenty-five of these were randomized for MR examination. This cardiac pacemaker is MR compatible only when the defined criteria are met on closed-bore 1,5 Tesla systems: The pacemaker has to be implanted for at least six weeks before scheduling MRI scanning. Before the patient is placed into a MR system, the pacemaker has to be switched into a MR compatible mode by a cardiologist or technician. After the scan the pacemaker is switched back and checked. Specific absorption rate (SAR) for the whole body must not exceed 2.0 W/kg, 3.2 W/kg for the cranial region (of the head 3.2 W/kg), with a slew rate that should not exceed 200 T/m/s. Conclusion. We recommend checking the type of the pacemaker and electrodes with a chest x-ray before scanning. The scanning isocenter cannot be focused between C1 and T12. All patients have to be monitored during MRI; i.e., ECG or pulse oxymetry or blood-pressure monitoring. The lateral decubitus position is not allowed.
- MeSH
- bezpečnost vybavení přístrojové vybavení trendy využití MeSH
- implantované elektrody kontraindikace virologie MeSH
- kardiostimulace umělá kontraindikace metody trendy MeSH
- kardiostimulátor kontraindikace trendy využití MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody přístrojové vybavení využití MeSH
- prospektivní studie MeSH
- referenční standardy MeSH
- rentgendiagnostika hrudníku využití MeSH
- spotřebitelská bezpečnost produktů normy MeSH
- Check Tag
- lidé MeSH
The goal of this study was an administration of the navigation task in a three-dimensional virtual environment to localize the electroencephalogram (EEG) features responsible for egocentric and allocentric reference frame processing in a horizontal and also in a vertical plane. We recorded the EEG signal of a traverse through a virtual tunnel to search for the best signal features that discriminate between specific strategies in particular plane. We identified intrahemispheric coherences in occipital-parietal and temporal-parietal areas as the most discriminative features. They have 10% lower error rate compared to single electrode features adopted in previous studies. The behavioral analysis revealed that 11% of participants switched from egocentric to allocentric strategy in a vertical plane, while 24% of participants consistently adopted egocentric strategy in both planes.
- MeSH
- Bayesova věta MeSH
- beta rytmus EEG MeSH
- dospělí MeSH
- elektrody MeSH
- elektroencefalografie MeSH
- funkční lateralita fyziologie MeSH
- lidé MeSH
- mladý dospělý MeSH
- počítačová grafika MeSH
- počítačové zpracování signálu MeSH
- pohlavní dimorfismus MeSH
- psychomotorický výkon fyziologie MeSH
- reprodukovatelnost výsledků MeSH
- spánkový lalok fyziologie MeSH
- temenní lalok fyziologie MeSH
- theta rytmus EEG MeSH
- týlní lalok fyziologie MeSH
- uživatelské rozhraní počítače MeSH
- vlnková analýza MeSH
- vnímání prostoru fyziologie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH