The anthracycline (ANT) anticancer drugs such as doxorubicin or daunorubicin (DAU) can cause serious myocardial injury and chronic cardiac dysfunction in cancer survivors. A bisdioxopiperazine agent dexrazoxane (DEX) has been developed as a cardioprotective drug to prevent these adverse events, but it is uncertain whether it is the best representative of the class. The present study used a rabbit model of chronic ANT cardiotoxicity to examine another bisdioxopiperazine compound called GK-667 (meso-(butane-2,3-diylbis(2,6-dioxopiperazine-4,1-diyl))bis(methylene)-bis(2-aminoacetate) hydrochloride), a water-soluble prodrug of ICRF-193 (meso-4,4'-(butan-2,3-diyl)bis(piperazine-2,6-dione)), as a potential cardioprotectant. The cardiotoxicity was induced by DAU (3 mg/kg, intravenously, weekly, 10 weeks), and GK-667 (1 or 5 mg/kg, intravenously) was administered before each DAU dose. The treatment with GK-667 was well tolerated and provided full protection against DAU-induced mortality and left ventricular (LV) dysfunction (determined by echocardiography and LV catheterization). Markers of cardiac damage/dysfunction revealed minor cardiac damage in the group co-treated with GK-667 in the lower dose, whereas almost full protection was achieved with the higher dose. This was associated with similar prevention of DAU-induced dysregulation of redox and calcium homeostasis proteins. GK-667 dose-dependently prevented tumor suppressor p53 (p53)-mediated DNA damage response in the LV myocardium not only in the chronic experiment but also after single DAU administration. These effects appear essential for cardioprotection, presumably because of the topoisomerase IIβ (TOP2B) inhibition provided by its active metabolite ICRF-193. In addition, GK-667 administration did not alter the plasma pharmacokinetics of DAU and its main metabolite daunorubicinol (DAUol) in rabbits in vivo. Hence, GK-667 merits further investigation as a promising drug candidate for cardioprotection against chronic ANT cardiotoxicity.
- MeSH
- chronická nemoc MeSH
- daunomycin MeSH
- diketopiperaziny farmakologie MeSH
- dysfunkce levé srdeční komory metabolismus patofyziologie prevence a kontrola MeSH
- fibróza MeSH
- funkce levé komory srdeční účinky léků MeSH
- HL-60 buňky MeSH
- inhibitory topoisomerasy II farmakologie MeSH
- kardiomyocyty účinky léků metabolismus patologie MeSH
- kardiomyopatie chemicky indukované metabolismus patofyziologie prevence a kontrola MeSH
- kardiotoxicita MeSH
- králíci MeSH
- lidé MeSH
- modely nemocí na zvířatech MeSH
- nádorový supresorový protein p53 metabolismus MeSH
- poškození DNA * MeSH
- prekurzory léčiv farmakologie MeSH
- remodelace komor účinky léků MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- lidé MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
PURPOSE: Patients with ischemic cardiomyopathy (ICM) are prone to scar-related ventricular tachycardia (VT). The success of VT ablation depends on accurate arrhythmogenic substrate localization, followed by optimal delivery of energy provided by constant electrode-tissue contact. Current manual and remote magnetic navigation (RMN)-guided ablation strategies aim to identify a reentry circuit and to target a critical isthmus through activation and entrainment mapping during ongoing tachycardia. The MAGNETIC VT trial will assess if VT ablation using the Niobe™ ES magnetic navigation system results in superior outcomes compared to a manual approach in subjects with ischemic scar VT and low ejection fraction. METHODS AND RESULTS: This is a randomized, single-blind, prospective, multicenter post-market study. A total of 386 subjects (193 per group) will be enrolled and randomized 1:1 between treatment with the Niobe ES system and treatment via a manual procedure at up to 20 sites. The study population will consist of patients with ischemic cardiomyopathy with left ventricular ejection fraction (LVEF) of ≤35% and implantable cardioverter defibrillator (ICD) who have sustained monomorphic VT. The primary study endpoint is freedom from any recurrence of VT through 12 months. The secondary endpoints are acute success; freedom from any VT at 1 year in a large-scar subpopulation; procedure-related major adverse events; and mortality rate through 12-month follow-up. Follow-up will consist of visits at 3, 6, 9, and 12 months, all of which will include ICD interrogation. CONCLUSIONS: The MAGNETIC VT trial will help determine whether substrate-based ablation of VT with RMN has clinical advantages over manual catheter manipulation. TRIAL REGISTRATION: Clinicaltrials.gov identifier: NCT02637947.
- MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory diagnostické zobrazování etiologie prevence a kontrola MeSH
- jednoduchá slepá metoda MeSH
- katetrizační ablace metody MeSH
- komorová tachykardie komplikace diagnostické zobrazování chirurgie MeSH
- lidé středního věku MeSH
- lidé MeSH
- magnetismus MeSH
- mapování potenciálů tělesného povrchu metody MeSH
- mladiství MeSH
- mladý dospělý MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- tepový objem MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- Geografické názvy
- Spojené státy americké MeSH
Cardiac resynchronization therapy (CRT) is an established treatment option for adult patients suffering heart failure due to idiopathic or ischemic cardiomyopathy associated with electromechanical dyssynchrony. There is limited evidence suggesting similar efficacy of CRT in patients with congenital heart disease (CHD). Due to the heterogeneity of structural and functional substrates, CRT implantation techniques are different with a thoracotomy or hybrid approach prevailing. Efficacy of CRT in CHD seems to depend on the anatomy of the systemic ventricle with best results achieved in systemic left ventricular patients upgraded to CRT from conventional pacing. Indications for CRT in patients with CHD were recently summarized in the Pediatric and Congenital Electrophysiology Society (PACES) and the Heart Rhythm Society (HRS) Expert Consensus Statement on the Recognition and Management of Arrhythmias in Adult Congenital Heart Disease and are presented in the text.
- MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory komplikace diagnóza prevence a kontrola MeSH
- lidé MeSH
- medicína založená na důkazech MeSH
- srdeční resynchronizační terapie metody MeSH
- srdeční selhání komplikace diagnóza prevence a kontrola MeSH
- vrozené srdeční vady komplikace diagnóza terapie MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
OBJECTIVE: To evaluate systolic dyssynchrony index (SDI) measured by real time three-dimensional echocardiography (RT3DE) and Doppler tissue imaging (DTI) dyssynchrony parameters in predicting the hemodynamic response to biventricular (BIV) pacing in the early postoperative period after cardiac surgery. To compare right ventricular (RV) and BIV pacing using invasively measured hemodynamic values. METHODS: A prospective randomized clinical study enrolling 11 patients with ischemic heart disease, concomitant valvular heart disease, and left ventricular ejection fraction (LVEF) ≤ 35% comparing preoperative SDI by RT3DE and DTI LV dyssynchrony parameters to hemodynamic values obtained during RV or BIV sequential (DDD) epicardial pacing in the first 72 hours after cardiac surgery. RESULTS: BIV pacing produced a statistically significant higher cardiac output (CO) (6.27 ± 1.55 L/min) and cardiac index (CI) (3.44 ± 0.93 L/min per m(2) ) than RV pacing (CO 5.44 ± 0.97 L/min, CI 3.03 ± 0.83 L/min per m(2) , P < 0.05). We found a statistically moderate correlation between preoperative SDI by RT3DE and CO (r = 0.596, P < 0.05) and a nonsignificant correlation to CI (r = 0.535, P < 0.10) during BIV pacing. No correlation was observed between DTI dyssynchrony parameters and measured hemodynamic values. BIV pacing reduced the ICU stay and inotropic support requirements of patients after heart surgery. CONCLUSIONS: SDI measured preoperatively using RT3DE can predict CO during BIV pacing in the early postoperative period after cardiac surgery. BIV pacing is more hemodynamically effective than RV pacing in patients with LV dysfunction after coronary artery bypass grafting with or without a valve procedure.
- MeSH
- dopplerovská echokardiografie metody MeSH
- dysfunkce levé srdeční komory prevence a kontrola ultrasonografie MeSH
- echokardiografie trojrozměrná metody MeSH
- kardiochirurgické výkony MeSH
- lidé MeSH
- pilotní projekty MeSH
- počítačové systémy MeSH
- pooperační péče MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- srdeční resynchronizační terapie * MeSH
- stupeň závažnosti nemoci MeSH
- systolické srdeční selhání prevence a kontrola ultrasonografie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
- MeSH
- dysfunkce levé srdeční komory prevence a kontrola MeSH
- lidé MeSH
- syndrom neklidných nohou komplikace patologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- novinové články MeSH
Severe aortic stenosis (AS) has a poor prognosis when associated with left ventricular dysfunction and congestive heart failure. Despite a relatively high operative mortality, most patients with severe AS and a depressed left ventricular ejection fraction (LVEF) should be considered candidates for aortic valve replacement. The CentriMag left ventricular assist system (Levitronix) can be used for perioperative or postcardiotomy circulatory support for the failing heart. In this case report, we report the successful use of the Levitronix CentriMag device as perioperative support in a high-risk patient with severe AS, significant mitral insufficiency, and a poor LVEF with advanced organ failure.
- MeSH
- aortální stenóza komplikace prevence a kontrola MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory komplikace prevence a kontrola MeSH
- kardiogenní šok komplikace prevence a kontrola MeSH
- lidé MeSH
- mitrální insuficience komplikace prevence a kontrola MeSH
- perioperační péče metody MeSH
- podpůrné srdeční systémy MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
- MeSH
- chronické selhání ledvin imunologie klasifikace terapie MeSH
- dysfunkce levé srdeční komory farmakoterapie prevence a kontrola MeSH
- kardiovaskulární nemoci epidemiologie etiologie mortalita MeSH
- lidé MeSH
- nutriční terapie MeSH
- rizikové faktory MeSH
- stupeň závažnosti nemoci MeSH
- zánět prevence a kontrola terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- novinové články MeSH
Observational studies suggest that conventional right ventricular apical pacing may have a deleterious effect on left ventricular function. In this study, we examined whether biventricular pacing is superior to right ventricular apical pacing in preventing deterioration of left ventricular systolic function and cardiac remodeling in patients with bradycardia and a normal ejection fraction. METHODS: In this prospective, double-blind, multicenter study, we randomly assigned 177 patients in whom a biventricular pacemaker had been successfully implanted to receive biventricular pacing (89 patients) or right ventricular apical pacing (88 patients). The primary end points were the left ventricular ejection fraction and left ventricular end-systolic volume at 12 months. RESULTS: At 12 months, the mean left ventricular ejection fraction was significantly lower in the right-ventricular-pacing group than in the biventricular-pacing group (54.8+/-9.1% vs. 62.2+/-7.0%, P<0.001), with an absolute difference of 7.4 percentage points, whereas the left ventricular end-systolic volume was significantly higher in the right-ventricular-pacing group than in the biventricular-pacing group (35.7+/-16.3 ml vs. 27.6+/-10.4 ml, P<0.001), with a relative difference between the groups in the change from baseline of 25% (P<0.001). The deleterious effect of right ventricular apical pacing occurred in prespecified subgroups, including patients with and patients without preexisting left ventricular diastolic dysfunction. Eight patients in the right-ventricular-pacing group (9%) and one in the biventricular-pacing group (1%) had ejection fractions of less than 45% (P=0.02). There was one death in the right-ventricular-pacing group, and six patients in the right-ventricular-pacing group and five in the biventricular-pacing group were hospitalized for heart failure (P=0.74). CONCLUSIONS: In patients with normal systolic function, conventional right ventricular apical pacing resulted in adverse left ventricular remodeling and in a reduction in the left ventricular ejection fraction; these effects were prevented by biventricular pacing. (Centre for Clinical Trials number, CUHK_CCT00037.) 2009 Massachusetts Medical Society
- MeSH
- atrioventrikulární blokáda komplikace MeSH
- bradykardie etiologie patofyziologie terapie MeSH
- dvojitá slepá metoda MeSH
- dysfunkce levé srdeční komory etiologie prevence a kontrola terapie MeSH
- echokardiografie trojrozměrná MeSH
- financování organizované MeSH
- funkce levé komory srdeční MeSH
- kardiostimulátor MeSH
- kvalita života MeSH
- lidé MeSH
- objem srdce MeSH
- prospektivní studie MeSH
- randomizované kontrolované studie jako téma MeSH
- remodelace komor MeSH
- senioři MeSH
- syndrom chorého sinu komplikace MeSH
- tepový objem MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- multicentrická studie MeSH
- srovnávací studie MeSH
INTRODUCTION: The benefits conferred by cardiac resynchronization therapy (CRT) are markedly influenced by the left ventricular (LV) lead placement. Little is known regarding the optimal right ventricular (RV) stimulation site.
- MeSH
- dysfunkce levé srdeční komory diagnóza prevence a kontrola MeSH
- implantace protézy metody statistika a číselné údaje MeSH
- implantované elektrody statistika a číselné údaje MeSH
- kardiostimulace umělá statistika a číselné údaje MeSH
- kardiostimulátor statistika a číselné údaje MeSH
- lidé MeSH
- longitudinální studie MeSH
- prevalence MeSH
- senioři MeSH
- srdeční komory chirurgie MeSH
- srdeční septum chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Geografické názvy
- Česká republika MeSH
AIMS: To analyse left ventricular (LV) synchrony and function with respect to the epicardial pacing site in the young. METHODS AND RESULTS: Left ventricular function and synchrony (M-mode, speckle tracking) were evaluated during mid-term follow-up in 32 children with complete non-surgical (n = 15) or surgical (n = 17) atrioventricular block (structural heart disease in 21/32) paced from LV apex (n = 19), right ventricular (RV) apex (n = 7), and RV free wall (n = 6), respectively. Data are in the following order: LV apical, RV apical, and RV free wall pacing. Septal to posterior wall motion delay (SPWMD) = median 0, 69, and 136 ms (P < 0.001), septal to lateral mechanical delay = 54 +/- 29, 73 +/- 24, and 129 +/- 70 ms (P = 0.001), apical to basal mechanical delay = 96 +/- 37, 106 +/- 50, and 79 +/- 18 ms (P NS), and LV ejection fraction (LVEF) = 57 +/- 9, 49 +/- 12, and 33 +/- 10% (P < 0.001), respectively. Left ventricular ejection fraction correlated negatively with SPWMD (R(2) = 0.454, P < 0.001) and septal to lateral mechanical delay (R(2) = 0.320, P < 0.001) but not with apical to basal mechanical delay. Right ventricular free wall pacing (P = 0.014) and SPWMD (P = 0.044) were negative multivariable predictors of LVEF. CONCLUSION: Compared with other sites, LV apical pacing preserves septal to lateral LV synchrony and systolic function and may be the preferred epicardial pacing site in the young.
- MeSH
- dítě MeSH
- dospělí MeSH
- dysfunkce levé srdeční komory * etiologie prevence a kontrola MeSH
- implantace protézy * metody MeSH
- implantované elektrody * MeSH
- kardiostimulace umělá * metody MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- předškolní dítě MeSH
- srdeční selhání * komplikace prevence a kontrola MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- kojenec MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- předškolní dítě MeSH
- ženské pohlaví MeSH
- Publikační typ
- klinické zkoušky kontrolované MeSH
- práce podpořená grantem MeSH