Background: The ablation of cavotricuspid-isthmus (CTI) atrial flutter (AFL) dependent atrial flutter could be difficult in patients with complex anatomy of the CTI.The aim of the study was to assess whether the use of intracardiac echocardiography (ICE) was associated with less fluoroscopy time and faster ablations of cavotricuspid isthmus dependent atrial flutter (CTI-AFL). Methods: Patients with an indication for an ablation of a CTI-AFL were enrolled. Patients in which ablation of a CTI-AFLas part of an atrial fibrillation ablation were not included. Randomization was done using the envelope method. Standard techniques (i.e., coronary sinus, 20-polar halo catheter, and an ablation catheter), and criteria of success (bidirectional block through the CTI) were used. In patients randomized to the ablation with ICE, a 10F AcuNav ICE probe (Siemens, Germany)was used. Results: Seventy-nine patients were enrolled; 40 were randomized to ablation with ICE and 39 without ICE. The X-ray exposure was shorter (3.29±2.6 vs. 5.94±3.43 min, p<0.001) and total X-ray dose was reduced (3.30±1.98 vs. 6.68±5.25 Gy.cm2, p<0.001) in the ICE group. However, the total RF energy ablation time was not different between groups (ICE group: 604.56±380.46sec vs. 585.82±373.39 sec, p=0.8). The procedure duration was slightly longer in the ICE group (82.0±20.8 vs. 72.1±19.0 min, p=0.03). Procedural success was 100% (40/40) in the ICE group and 95% (37/39) in the control group. Two control patients required crossover to ICE at a prespecified point to achieve bidirectional block. There were two femoral hematomas in the ICE group and one in the control group. Conclusion: The use of ICE for atrial flutter ablation is associated with less fluoroscopy time and improved ability to achieve bidirectional block compared to traditional conventional flutter ablation methods. However, it is not asoociated with reduced ablation time or overall procedure duration.
- Publikační typ
- časopisecké články MeSH
- MeSH
- atrioventrikulární blokáda komplikace diagnóza terapie MeSH
- elektrokardiografie * MeSH
- Hisův svazek MeSH
- infarkt myokardu komplikace diagnostické zobrazování chirurgie MeSH
- kardiostimulace umělá * MeSH
- koronární angiografie MeSH
- koronární angioplastika * MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- Check Tag
- lidé MeSH
- senioři nad 80 let MeSH
- Publikační typ
- časopisecké články MeSH
- kazuistiky MeSH
Background: Hybrid ablation [thoracoscopic ablation (TA) of atrial fibrillation (AF) followed by catheter ablation (CA)] is an increasingly common method of the treatment for patients with AF. The aim of this study was to assess the response to ganglionated plexi (GP) ablation in patients with a previous TA (i.e., to assess whether TA had resulted in damage to the GP. Heart rate variability (HRV) was used as a marker of the autonomic response. Methods: Twenty AF patients underwent pulmonary vein isolation (PVI) plus GP ablation (GP group) and 18 AF patients underwent CA including GP ablation as a part of hybrid ablation (i.e., all patients had undergone a previous TA; Hybrid group). In each group, a 5 min electrocardiogram (ECG) obtained before and after the CA were analyzed. Time and frequency domain parameters were evaluated. Results: Vagal responses (VR) during CA were observed in 12 (60%) patients in the GP group; however, in the Hybrid group, VR was not observed in any of the patients during CA. The change in normalized power in the low frequency (LF) component and the ratio between the LF and high frequency (LF/HF ratio) components of the HRV spectra, before and after ablation, were statistically significant in the GP group (3.3±2.6 beforevs.1.8±1.9 after ablation) but unchanged, before or after CA, in the Hybrid group. Conclusions: GP ablation in patients subsequent to TA has a little influence on HRV parameters, which could be explained by GP damage during the preceding TA.
- Publikační typ
- časopisecké články MeSH
Earthworms are not endowed with adaptive immunity and they are rely on the tools of innate immunity. Cells of the innate immune system utilize pattern recognition receptors, such as Toll-like receptors, to detect the pathogen-associated molecular patterns (PAMPs). The first earthworm TLR was isolated from Eisenia andrei earthworms (EaTLR), which belongs to the single cysteine cluster TLR (sccTLR). Here, we identified a new multiple cysteine cluster TLR (mccTLR) in E. andrei earthworms. Phylogenetic DNA analysis revealed that it has no variability within one earthworm as well as in the population. By screening of the tissue expression profile, the TLR was expressed primarily in earthworm seminal vesicles and receptacles suggesting a connection to sperm cells. Seminal vesicles are often heavily infected by gregarine parasites. As a sign of immune response, a strong melanization reaction is visible around parasites. Stimulation experiments with profilin from related parasite Toxoplasma gondii, led to the upregulation of mccEaTLR in the earthworm seminal vesicles. Also, profilin activated prophenoloxidase cascade, the efficient mechanism of innate immunity. However, its involvement in the NF-κB signaling was not proven. Further, we provide evidence that the antibiotics metronidazole and griseofulvin destroyed the developing spermatocytes. The observed decrease in the mccEaTLR mRNA levels after the antibiotic treatment of parasites is caused by the decline of sperm cells numbers rather than by diminution of the parasites. Since earthworms with extensively reduced parasite load had a similar amount of mccEaTLR mRNA, presumably, earthworm sperm cells have a certain level of mccEaTLR expressed as a standard, which can be augmented by particular antigenic stimulation. Also, mccEaTLR was expressed mainly in the early stages of earthworm development and presumably is primarily involved in early embryonic development. Expression of mccEaTLR in seminal vesicles correlates with the expression of endothelial monocyte-activation polypeptide II. High-throughput sequencing of gregarine DNA from seminal vesicles of individual earthworms resulted in great diversity of the observed genotypes. Phylogenetically, all observed OTUs belong to the clade of earthworm gregarines suggesting host specificity. Overall, mccEaTLR is supposed to play a function role in early embryonic development and potentially it participates in immune response against parasites.
- MeSH
- cystein MeSH
- cytokiny imunologie MeSH
- embryonální vývoj imunologie MeSH
- fylogeneze MeSH
- messenger RNA imunologie MeSH
- nádorové proteiny imunologie MeSH
- NF-kappa B imunologie MeSH
- Oligochaeta imunologie MeSH
- přirozená imunita imunologie MeSH
- proteiny vázající RNA imunologie MeSH
- receptory rozpoznávající vzory imunologie MeSH
- signální transdukce imunologie MeSH
- toll-like receptory imunologie MeSH
- Toxoplasma imunologie MeSH
- upregulace imunologie MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
The location of the pacemaker lead is based on the shape of the lead on fluoroscopy only, typically in the left and right anterior oblique positions. However, these fluoroscopy criteria are insufficient and many leads apparently considered to be in septum are in fact anchored in anterior wall. Periprocedural ECG could determine the correct lead location. The aim of the current analysis is to characterize ECG criteria associated with a correct position of the right ventricular (RV) lead in the mid-septum. Patients with indications for a pacemaker had the RV lead implanted in the apex (Group A) or mid-septum using the standard fluoroscopic criteria. The exact position of the RV lead was verified using computed tomography. Based on the findings, the mid-septal group was divided into two subgroups: (i) true septum, i.e. lead was found in the mid-septum, and (ii) false septum, i.e. lead was in the adjacent areas (anterior wall, anteroseptal groove). Paced ECGs were acquired from all patients and multiple criteria were analysed. Paced ECGs from 106 patients were analysed (27 in A, 36 in true septum, and 43 in false septum group). Group A had a significantly wider QRS, more left-deviated axis and later transition zone compared with the true septum and false septum groups. There were no differences in presence of q in lead I, or notching in inferior or lateral leads between the three groups. QRS patterns of true septum and false septum groups were similar with only one exception of the transition zone. In the multivariate model, the only ECG parameters associated with correct lead placement in the septum was an earlier transition zone (odds ratio (OR) 2.53, P = 0.001). ECGs can be easily used to differentiate apical pacing from septal or septum-close pacing. The only ECG characteristic that could help to identify true septum lead position was the transition zone in the precordial leads. ClinicalTrials.gov identifier: NCT02412176.
- Publikační typ
- časopisecké články MeSH
PURPOSE: Hybrid ablation of atrial fibrillation (AF) is a promising treatment strategy for patients with non-paroxysmal AF, although, data regarding mid-term outcomes are limited. METHODS: Patients with persistent or long-standing persistent AF were enrolled. Initially, a thoracoscopic, right-sided, epicardial ablation was performed, with a goal of creating a box lesion on the posterior wall of the left atrium; a novel versapolar radiofrequency (RF) catheter was used. In patients enrolled later, occlusion of the left atrial appendage was also performed. An endocardial procedure was performed 2-4 months later, with the goal of confirming/completing the box lesion and ablating the ganglionated plexi and cavotricuspid isthmus. Efficacy was assessed using multiple 24-h and 1-week Holter monitoring. Analysis was performed to search for variables associated with procedure's failure. RESULTS: Forty-one patients (14 persistent and 27 long-standing persistent AF) were enrolled with a mean AF duration of 33.5 ± 33.1 months. Mean follow-up was 507.2 ± 201.1 days (180-731). At the last follow-up visit, 27(65%) patients were arrhythmia-free, without anti-arrhythmics or need for re-ablation. Additional 4 patients (9.8%) were in sinus rhythm (SR) following re-ablation of postprocedural peri-mitral flutter and 4 (9.8%) were in SR on anti-arrhythmics. Longer periods of preoperative AF were independently associated with worse arrhythmia-free survival (p = 0.015). Serious postoperative complications occurred in 3 (7.3%) patients; only 1 (2.4%) patient had clinical consequences after 6 months. CONCLUSIONS: Hybrid ablation of non-paroxysmal AF using a novel, versapolar RF device yields promising mid-term results. Better arrhythmia-free survival rates were found in AF patients with shorter AF duration.
- MeSH
- bezpečnost vybavení MeSH
- časové faktory MeSH
- chronická nemoc MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní metody MeSH
- elektrokardiografie metody MeSH
- fibrilace síní diagnostické zobrazování chirurgie MeSH
- hodnocení rizik MeSH
- katetrizační ablace přístrojové vybavení metody MeSH
- kohortové studie MeSH
- lidé středního věku MeSH
- lidé MeSH
- monitorování fyziologických funkcí přístrojové vybavení metody MeSH
- následné studie MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Hybrid ablation (i.e., a combination of a thoracoscopic surgical ablation followed by a catheter ablation) is a treatment option for patients with non-paroxysmal atrial fibrillation (AF). Despite its promising efficacy, it is a surgical procedure with a relatively high risk of complications that could affect the quality of life (QoL) of patients, even when sinus rhythm is restored. OBJECTIVE: To describe changes in the QoL of patients with non-paroxysmal AF before and after a hybrid ablation. METHODS: Patients after hybrid ablation for persistent or long-standing persistent AF were prospectively studied. Follow-up visits were scheduled at 1, 3, 6, 9, and 12 months. The maintenance of SR was assessed using 1-week Holter recordings at 6 and 12 months and 24-h Holter recordings at 3 and 9 months, or via an implantable loop recorder. QoL was assessed using the Atrial Fibrillation Effect on Quality-of-life (AFEQT) and the EuroQoL-5Dimensions (EQ-5D) questionnaires before and 12 months after ablation. RESULTS: Seventy-five patients (49 men, age 62.9 ± 8.45 years, 48 (64%) with long-standing persistent AF) were enrolled. Fifty-two (69.3%, SR group) were AF-free during the 12-month follow-up, 16 (21.3%, PAROX group) had only paroxysms of AF after ablation, and 7 (9.3%, PERM group) were on rate control due to permanent AF reoccurrence. The AFEQT score increased significantly in the SR group from 59.9 ± 19.4 to 91.4 ± 10.8 (p < 0.001), and in the PAROX group from 58.8 ± 19.0 to 81.5 ± 14.1 (p = 0.002) but remained unchanged in the PERM group (44.6 ± 7.5 vs. 47.4 ± 5.5, p = 0.24). The EQ-5D score significantly decreased in the descriptive part (from 7.90 ± 2.61 to 6.64 ± 1.90, p = 0.0001) and increased on the visual analog scale (from 63.56 ± 19.11 to 79.30 ± 16.9, p < 0.0001) in the SR group. In the PAROX group, no significant change was present on either the descriptive part (p = 0.3) or in the visual analog scale (p = 0.48). Similarly, no significant changes were present on either the descriptive part (p = 0.93) or the visual analog scale (p = 0.4) in the PERM group. CONCLUSION: The QoL of patients with non-paroxysmal AF and patients with AF paroxysms, after successful hybrid ablation, improved significantly in patients with SR. No significant improvement was present in patients on rate control after an unsuccessful ablation.
- MeSH
- elektrokardiografie ambulantní MeSH
- fibrilace síní chirurgie MeSH
- katetrizační ablace metody MeSH
- kvalita života * MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- průzkumy a dotazníky MeSH
- torakoskopie * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: We aimed to compare the acute differences in left ventricular (LV) function and mechanical synchrony during nonselective His bundle pacing (ns-HBP) versus selective His bundle pacing (s-HBP) using strain echocardiography. METHODS AND RESULTS: Consecutive patients with permanent His bundle pacing, in whom it was possible to obtain both s-HBP and ns-HBP, were studied in two centers. In each patient, echocardiography was performed sequentially during s-HBP and ns-HBP. Speckle-tracking echocardiography parameters were analyzed: Global longitudinal strain (GLS), the time delay between peak systolic strain in the basal septal and basal lateral segments (BS-BL delay), peak strain dispersion (PSD) and strain delay index. Right ventricle function was assessed using tricuspid annular plane systolic excursion (TAPSE) and tissue Doppler velocity of the lateral tricuspid annulus (S'). A total of 69 patients (age: 75.6 ± 10.5 years; males: 75%) were enrolled. There were no differences in LV ejection fraction and GLS between s-HBP and ns-HBP modes: 59% versus 60%, and -15.6% versus -15.7%, respectively; as well as no difference in BS-BL delay and strain delay index. The PSD value was higher in the ns-HBP group than in the s-HBP group with the most pronounced difference in the basal LV segments. No differences in right ventricular function parameters (TAPSE and S') were found. CONCLUSION: The ns-HBP and s-HBP modes seem comparable regarding ventricular function. The dyssynchrony parameters were significantly higher during ns-HBP, however, the difference seems modest and clarification of its impact on LV function requires a larger long-term study.
Orthopedic implants heal well without complications in most patients but fail for unclear reasons in some individuals. This study determined the relevance of metal hypersensitivity in patients with failed orthopedic implants and those requiring orthopedic implant surgery. The study included 35 patients with failed orthopedic implants and 15 subjects scheduled for orthopedic implant surgery. The production of selected pro-inflammatory cytokines was measured in patients with failed orthopedic implants. Metal hypersensitivity was measured in all subjects using the MELISA® test. Of common metals in orthopedic alloys, the patients with failed orthopedic implants responded most frequently to nickel, chromium, titanium, iron, and molybdenum. Hypersensitivity to metals found in implants was measured in 40% of patients with failed implants. The study also showed that titanium exposure in patients with titanium hypersensitivity might lead to implant failure. Metal hypersensitivity testing should be offered to patients before surgery to minimize the risk of implant failure.