BIOLOGICAL ASSAY Dotaz Zobrazit nápovědu
Symposia series in immunobiological standardization ; vol. 10
14, 262 s. : il.
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- alergologie a imunologie
- urgentní lékařství
elektronický časopis
- Konspekt
- Biologické vědy
- NLK Obory
- biologie
- NLK Publikační typ
- elektronické časopisy
Contents -- Introduction 1 -- General 1 -- Needs for expert advice 1 -- Distribution of International Biological and related substances 11 -- Follicle-stimulating hormone 11 -- Inhibin 12 -- Requirements for biological General 2 -- 2.1 Current directions 2 -- 2.1.1 Strategie directions in biological Standardization 2 - - 2.1.2 Vaccines and biological therapeutics: recent and planned activities in -- biological standardization 3 -- 2.1.3 Blood products and related in vitro diagnostics: recent and planned activities in biological
WHO technical report series
sv.
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- veřejné zdravotnictví
- biologie
- NLK Publikační typ
- ročenky
Výroba koksu představuje jednu z nejvyšších expozic polycyklickým aromatickým uhlovodíkům (PAU) v pracovním prostředí. Genotoxické účinky PAU na stropu koksárenské baterie byly hodnoceny metodou „Single cell gel assay“ („comet assay“), která odhaluje jednořetězcové zlomy a alkalilabilní místa DNA (biomarker expozice). Vnímavost jedinců k působení PAU byla analyzo- vána detekcí polymorfismu genů glutathion S-transferázy M1 (GSTM1) a N-acetyl transferázy 2 (NAT-2) (biomarkery vnímavosti). Studie zahrnuje 24 pracovníků koksáren, kontrolní skupinu tvoří 12 pracovníků železáren a dalších 16 osob z města. Expozice PAU byla hodnocena osobními odběrovými soupravami 8 hodin před odebráním vzorků krve a moče. Pracovníci z koksáren byli expono- váni karcinogennímu PAU (medián, rozpětí) za směnu 18,7 mg/m 3 (5,1 - 300,2 mg/m 3 ), kontrola ze železáren 0,41 mg/m 3 (0,12 - 1,22 mg/m 3 ), kontrola z města 0,58 mg/m 3 (0,09 - 1,64 mg/m 3 ). Při detekci poškození DNA metodou „comet assay“ v periferních lymfocytech bylo hodnoceno % DNA v ocase komety (%T) a délka ocasu komety (TL) v mm. Nejvyšší úroveň %T a TL byla pozorována u kontrolní skupiny ze železáren 14,5 (6,1 - 15,7), 23,5 (11,6-35,8) vs. 6,2 (13,2 - 15,4) a 11,4 (7,4 - 29,5) u exponované skupiny a 5,9 (3,8 - 11,0), 10,9 (8,4 - 20,0) u kontrolní skupiny z města. Rozdíly nebyly pozorovány ani při použití koeficientu disperze. Parametry „comet assay“ nebyly ovlivněny kouřením ani genotypy GSTM1 a NAT-2. Určení parametrů „comet assay“ v periferních lymfocytech pracovníků koksáren neodráželo expozici karcinogenním PAU v koksárenských emisích.
Coke oven production represents one of the highest exposures of PAHs in the working environment. Genotoxic effects of PAHs on the top-side of coke oven battery were evaluated by the „Single cell gel assay“ (comet assay), detecting the DNA single strand breaks and alkalilabile sites (biomarkers of exposure). Individual susceptibility to PAH exposure was analysed by glutathion S-transferase M1 (GSTM1) polymorphism and N-acetyl transferase 2 (NAT-2) polymorphism detection (biomarkers of susceptibili- ty). The study included 24 subjects from coke-oven, 12 subjects of controls from iron-work and other 16 subjects from town. Exposure to PAHs was determined by personal exposure monitoring 8 h before the collection of blood and urine samples. Coke-oven workers were exposed to carcinogenic PAHs (median, range) in the course of shift 18.7 mg/m 3 (5.1 - 300.2 mg/m 3 ), controls from iron-work 0.41 mg/m 3 (0.12 - 1.22 mg/m 3 ), controls from town 0.58 mg/m 3 (0.09 - 1.64 mg/m 3 ). The following comet parameters were evaluated in peripheral lymphocytes 100 images/sample: percentage of DNA in comet tail (%T), comet tail length (TL) in mm. The highest level of %T and TL was observed in controls from iron-work 14.5 (6.1 - 15.7) and 23.5 (11.6 - 35.8) vs. 6.2 (3.2 - 15.4) and 11.4 (7.4 - 29.5) in coke- oven workers vs. 5.9 (3.8 - 11.0) and 10.9 (8.4 - 20.0) in controls from town, respectively. Any differences were not seen either using coefficient of dispersion. No effects of smoking or GSTM1 or NAT-2 polymorphism were observed for any of comet parameters. According to our results it seems that the comet assay in the peripheral lymphocytes of coke-oven workers was not a particularly sensitive technique to determine the effects of carcinogenic PAHs at the DNA level, if peripheral lymphocytes were used.
- MeSH
- biologické markery MeSH
- dospělí MeSH
- karcinogeny MeSH
- koks MeSH
- látky znečišťující vzduch v pracovním prostředí MeSH
- lidé MeSH
- polycyklické aromatické uhlovodíky škodlivé účinky MeSH
- poškození DNA MeSH
- pracovní expozice MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- srovnávací studie MeSH
An immunosensor for the assay of toxic biological warfare agents is a biosensor suitable for detecting hazardous substances such as aflatoxin, botulinum toxin, ricin, Shiga toxin, and others. The application of immunosensors is used in outdoor assays, point-of-care tests, as a spare method for more expensive devices, and even in the laboratory as a standard analytical method. Some immunosensors, such as automated flow-through analyzers or lateral flow tests, have been successfully commercialized as tools for toxins assay, but the research is ongoing. New devices are being developed, and the use of advanced materials and assay techniques make immunosensors highly competitive analytical devices in the field of toxic biological warfare agents assay. This review summarizes facts about current applications and new trends of immunosensors regarding recent papers in this area.