Eluate Dotaz Zobrazit nápovědu
We report on a Lab-On-Valve (LOV) configuration for analyte preconcentration from milliliter sample volumes using confluent mixing in the holding coil for in-line addition of loading buffer. The system was applied to the spectrophotometric determination of iron(II) in acidified seawater using 1,10-phenanthroline as color reagent. A cellulose-based chelating sorbent containing 8-hydroxyquinoline was used for the first time in LOV and excellent retention behavior and loading capacity were found. The flow system employs a syringe pump for handling all solutions (sorbent suspension, loading buffer, water, eluent, and color reagent) and a peristaltic pump for sample propulsion and includes a fit-for-purpose 14 cm long detection glass flow cell and a bubble trap for in-line carrier degasification. Advantage was taken of the LOV flow-through port to keep the eluted analytes for re-aspiration for subsequent chromogenic reaction. In effect, a universal analyzer configuration and preconcentration procedure was developed, which is combinable with other analytes, sorbents, and reagents. Among the studied parameters were the compositions, pH, volumes, and flow rates of loading buffer, eluent, and color reagent, as well as the microcolumn size, repeatability, and system stability. Reproducibility of 4.1% RSD over the entire working range, a LOD of down to 5 nmol L(-1), sampling frequency of 12h(-1), and linearity up to 1 µmol L(-1) for 3.3 mL of sample were obtained and applicability to real samples was demonstrated. It was proven that both Fe(III) and Fe(II) were retained and yielded similar recovery and sensitivity values. The method was applied to coastal seawater samples and spiking experiments yielded recovery values close to 100%.
- MeSH
- barva MeSH
- celulosa chemie MeSH
- chelátory chemie MeSH
- extrakce na pevné fázi MeSH
- fenantroliny chemie MeSH
- koncentrace vodíkových iontů MeSH
- limita detekce * MeSH
- metody pro přípravu analytických vzorků přístrojové vybavení metody MeSH
- mořská voda chemie MeSH
- oxychinolin chemie MeSH
- pufry MeSH
- reprodukovatelnost výsledků MeSH
- železo analýza chemie izolace a purifikace MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Cílem studie bylo nezávislé ověření kvality laboratorních stanovení fekálního kalprotektinu dle zásad ČSN EN ISO 15189 s použitím defino- vaných eluátů stolice. Mezilaboratorního porovnání testu fekálního kalprotektinu se zúčastnilo 14 laboratoří z ČR. Laboratoře obdržely po jednom alikvotutří fekálních eluátů a provedly stanovení hladiny kalprotektinu s pomocí rutinně používané diagnostické soupravy. Při hodnocení kvalitativních výsledků stanovení bylo dosaženo konsenzu u všech tří vzorků negativního, hraničního i pozitivního.
The aim of the study was an independent interlaboratory comparison of the fecal calprotectin detection according to the princip les of ISO 15189 using defined fecal eluates. Fourteen Czech laboratories have taken part in the comparison cycle, each laboratory obtained one aliquot of three fecal eluates and determined the level of calprotectin with routinely used diagnostic kits. In qualitative evaluation of calpro tectin levels con- sensus was reached for all three samples – negative, borderline and positive.
- Klíčová slova
- fekální kalprotektin,
- MeSH
- dospělí MeSH
- feces chemie MeSH
- idiopatické střevní záněty diagnóza MeSH
- imunoanalýza metody statistika a číselné údaje MeSH
- imunoenzymatické techniky * klasifikace metody statistika a číselné údaje MeSH
- leukocytární L1-antigenní komplex * analýza diagnostické užití MeSH
- lidé středního věku MeSH
- lidé MeSH
- řízení kvality * MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
A European round robin test according to ISO 5725-2 was conceptually prepared, realised, and evaluated. The aim was to determine the inter-laboratory variability of the overall process for the ecotoxicological characterization of construction products in eluates and bioassays. To this end, two construction products BAM-G1 (granulate) and HSR-2 (roof sealing sheet), both made of EPDM polymers (rubber), were selected. The granular construction product was eluted in a one stage batch test, the planar product in the Dynamic Surface Leaching test (DSLT). A total of 17 laboratories from 5 countries participated in the round robin test: Germany (12), Austria (2), Belgium (1), Czech Republic (1) and France (1). A test battery of four standardised ecotoxicity tests with algae, daphnia, luminescent bacteria and zebrafish eggs was used. As toxicity measures, EC50 and LID values were calculated. All tests, except the fish egg test, were basically able to demonstrate toxic effects and the level of toxicity. The reproducibility of test results depended on the test specimens and the test organisms. Generally, the variability of the EC50 or LID values increased with the overall level of toxicity. For the very toxic BAM-G1 eluate a relative high variability of CV = 73%-110% was observed for EC50 in all biotests, while for the less toxic HSR-2 eluate the reproducibility of EC50 varied with sensitivity: it was very good (CV = 9.3%) for the daphnia test with the lowest sensitivity, followed by the algae test (CV = 36.4%). The luminescent bacteria test, being the most sensitive bioassay for HSR-2 Eluate, showed the highest variability (CV = 74.8%). When considering the complex overall process the reproducibility of bioassays with eluates from construction products was acceptable.
- MeSH
- Bacteria účinky léků MeSH
- biotest metody normy MeSH
- chemické látky znečišťující vodu analýza toxicita MeSH
- dánio pruhované MeSH
- Daphnia účinky léků MeSH
- ekotoxikologie metody normy MeSH
- elastomery toxicita MeSH
- ethyleny toxicita MeSH
- guma toxicita MeSH
- Heterokontophyta účinky léků MeSH
- odchylka pozorovatele MeSH
- reprodukovatelnost výsledků MeSH
- testy toxicity metody normy MeSH
- vejce MeSH
- zvířata MeSH
- Check Tag
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
Dialyser bioincompatibility is an important factor contributing to complications of hemodialysis with well known systemic consequences. Here we studied the local processes that occur on dialysis membranes by eluting proteins adsorbed to the polysulfone dialyser membranes of 5 patients after 3 consecutive routine maintenance hemodialysis sessions. At the end of each procedure, a plasma sample was also collected. These eluates and their accompanying plasma samples were separated by 2-dimensional gel electrophoresis; all proteins that were present in all patients were analyzed by tandem mass spectrometry; and a ratio of the relative spot intensity of the eluate to plasma was calculated. Of 153 proteins detected, 84 were found in all patients, 57 of which were successfully identified by mass spectrometry as 38 components of 23 unique proteins. In 10 spots the relative eluate intensity differed significantly from that in the plasma, implying preferential adsorption. These proteins included ficolin-2, clusterin, complement C3c fragment, and apolipoprotein A1. Our finding of a selective binding of ficolin-2 to polysulfone membranes suggests a possible role of the lectin complement pathway in blood-dialyser interactions.
- MeSH
- adsorpce MeSH
- apolipoprotein A-I MeSH
- dialýza ledvin přístrojové vybavení škodlivé účinky MeSH
- hmotnostní spektrometrie MeSH
- klusterin MeSH
- komplement C3c MeSH
- komplement analýza metabolismus MeSH
- lektiny MeSH
- lidé středního věku MeSH
- lidé MeSH
- membrány umělé MeSH
- polymery škodlivé účinky MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- sulfony škodlivé účinky MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Publikační typ
- práce podpořená grantem MeSH
BACKGROUND: Radioligand therapy using alpha emitters has gained more and more prominence in the last decade. Despite continued efforts to identify new appropriate radionuclides, the combination of 225Ac/213Bi remains among the most promising. Bismuth-213 has been employed in clinical trials in combination with appropriate vectors to treat patients with various forms of cancer, such as leukaemia, bladder cancer, neuroendocrine tumours, melanomas, gliomas, or lymphomas. However, the half-life of 213Bi (T1⁄2 = 46 min) implies that its availability for clinical use is limited to hospitals possessing a 225Ac/213Bi radionuclide generator, which is still predominantly scarce. We investigated a new Ac/Bi generator system based on using the composite sorbent α-ZrP-PAN (zirconium(IV) phosphate as active component and polyacrylonitrile as matrix). The developed 225Ac/213Bi generator was subjected to long-term testing after its development. The elution profile was determined and the elution yield, the contamination of the eluate with the parent 225Ac and the contamination of the eluate with the column material were monitored over time. RESULTS: The high activity (75 MBq of parent 225Ac) generator with a length of 75 mm and a diameter of 4 mm containing the composite sorbent α-ZrP-PAN with a particle size of 0.8 to 1.0 mm as the stationary phase, eluted with a mixture of 10 mM DTPA in 5 mM nitric acid, provided 213Bi with yields ranging from 77 % to 96 % in 2.8 mL of eluate, with parent 225Ac contamination in the order of 10-3 %, up to twenty days of use. CONCLUSION: All the results of the monitored parameters indicate that the composite sorbent α-ZrP-PAN based separation system for the elution of 213Bi is a very promising and functional solution.
Cíl: Podrobnější přehled běžně používaných 99Mo/99mTc generátorů a samotného 99mTc. Úvod: Technecium-99m je jedním z nejpoužívanějších diagnostických radionuklidů v nukleární medicíně. Denně je získáváno na pracovištích nukleární medicíny z radionuklidového generátoru 99Mo/99mTc pro potřeby přípravy širokého spektra radiofarmak. Téměř 90 % všech SPECT vyšetření je prováděno právě s pomocí radiofarmak značených 99mTc. Popis problematiky: Avšak za touto každodenní činností se skrývá nemálo procesů, které nejsou na první pohled vidět – od různých možností přípravy mateřského radionuklidu, přes jednotlivé konstrukce samotných radionuklidových generátorů až po zisk 99mTc. Také je pozornost v rámci tohoto článku zaměřena na důležité chemické a fyzikální vlastnosti 99mTc, díky kterým je tak hojně využíváno. I přes tyto procesy a vlastnosti je důležité nezapomínat ani na kontrolu kvality, kterou je nutné provádět před samotným použitím ať už eluátu či připraveného radiofarmaka. Technecium-99m je běžně využíváno pro diagnostiku nejen onkologických onemocnění. Své uplatnění nachází v kardiologii, nefrologii či neurologii. V rámci tohoto článku je uveden přehled nejběžněji používaných radiofarmak s možností jejich využití. Závěr: Důležitost 99Mo/99mTc generátoru je patrná a na jeho základě stojí většina vyšetření na pracovištích nukleární medicíny. Z tohoto důvodu je důležité si připomenout principy výroby a přípravy daných radionuklidů a dále vlastnosti, díky kterým je možné poměrně jednoduše daná radiofarmaka připravovat.
Aim: Review of daily used 99Mo/99mTc generator and 99mTc radionuclide itself. Introduction: Technetium-99m is one of the most widely used diagnostic radionuclides in nuclear medicine. It is daily obtained from 99Mo/99mTc radionuclide generator at nuclear medicine departments. It is mostly used for the preparation of a wide range of radiopharmaceuticals. Almost 90 % of all SPECT examinations are performed by 99mTc-labeled radiopharmaceuticals. Issue description: However, there are many processes behind these everyday operations that are not visible at first glance - from the various options of parent radionuclide preparation, through the individual radionuclide generators’ design, to the 99mTc elution itself. In this article, the attention is also focused on the important chemical and physical properties of the radionuclide - 99mTc, which makes it so widely used. Despite these processes and properties, it is important not to forget the quality control, which must be carried out before use, whether as regards the eluate or the prepared radiopharmaceutical. Technetium-99m is commonly used not only to cancer diagnoses. It is also used in cardiology, nephrology or neurology. This article provides an overview of the most commonly used radiopharmaceuticals with their possible usage. Conclusion: The importance of 99Mo/99mTc generator is evident and most examinations in nuclear medicine are based on it. For this reason, it is important to occasionally review the principles of production and preparation of given radionuclides and moreover, the characteristics that make it possible to prepare given radiopharmaceuticals quite easily. However, it is necessary also to mention the pitfalls and problems that these processes bring with them.
- Klíčová slova
- technecium-99m, molybden-99,
- MeSH
- lidé MeSH
- organotechneciové sloučeniny MeSH
- radiofarmaka MeSH
- radioisotopové generátory * MeSH
- řízení kvality MeSH
- technecium MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- práce podpořená grantem MeSH
- přehledy MeSH
Cíl: Podrobnější přehled běžně používaných 99Mo/99mTc generátorů a samotného 99mTc. Úvod: Technecium-99m je jedním z nejpoužívanějších diagnostických radionuklidů v nukleární medicíně. Denně je získáváno na pracovištích nukleární medicíny z radionuklidového generátoru 99Mo/99mTc pro potřeby přípravy širokého spektra radiofarmak. Téměř 90 % všech SPECT vyšetření je prováděno právě s pomocí radiofarmak značených 99mTc. Popis problematiky: Avšak za touto každodenní činností se skrývá nemálo procesů, které nejsou na první pohled vidět – od různých možností přípravy mateřského radionuklidu, přes jednotlivé konstrukce samotných radionuklidových generátorů až po zisk 99mTc. Také je pozornost v rámci tohoto článku zaměřena na důležité chemické a fyzikální vlastnosti 99mTc, díky kterým je tak hojně využíváno. I přes tyto procesy a vlastnosti je důležité nezapomínat ani na kontrolu kvality, kterou je nutné provádět před samotným použitím ať už eluátu či připraveného radiofarmaka. Technecium-99m je běžně využíváno pro diagnostiku nejen onkologických onemocnění. Své uplatnění nachází v kardiologii, nefrologii či neurologii. V rámci tohoto článku je uveden přehled nejběžněji používaných radiofarmak s možností jejich využití. Závěr: Důležitost 99Mo/99mTc generátoru je patrná a na jeho základě stojí většina vyšetření na pracovištích nukleární medicíny. Z tohoto důvodu je důležité si připomenout principy výroby a přípravy daných radionuklidů a dále vlastnosti, díky kterým je možné poměrně jednoduše daná radiofarmaka připravovat.
Aim: Review of daily used 99Mo/99mTc generator and 99mTc radionuclide itself. Introduction: Technetium-99m is one of the most widely used diagnostic radionuclides in nuclear medicine. It is daily obtained from 99Mo/99mTc radionuclide generator at nuclear medicine departments. It is mostly used for the preparation of a wide range of radiopharmaceuticals. Almost 90 % of all SPECT examinations are performed by 99mTc-labeled radiopharmaceuticals. Issue description: However, there are many processes behind these everyday operations that are not visible at first glance - from the various options of parent radionuclide preparation, through the individual radionuclide generators’ design, to the 99mTc elution itself. In this article, the attention is also focused on the important chemical and physical properties of the radionuclide – 99mTc, which makes it so widely used. Despite these processes and properties, it is important not to forget the quality control, which must be carried out before use, whether as regards the eluate or the prepared radiopharmaceutical. Technetium-99m is commonly used not only to cancer diagnoses. It is also used in cardiology, nephrology or neurology. This article provides an overview of the most commonly used radiopharmaceuticals with their possible usage. Conclusion: The importance of 99Mo/99mTc generator is evident and most examinations in nuclear medicine are based on it. For this reason, it is important to occasionally review the principles of production and preparation of given radionuclides and moreover, the characteristics that make it possible to prepare given radiopharmaceuticals quite easily. However, it is necessary also to mention the pitfalls and problems that these processes bring with them.
- Klíčová slova
- radionuklidový generátor, jaderný reaktor,
- MeSH
- lidé MeSH
- molybden MeSH
- radiofarmaka * MeSH
- radioisotopové generátory MeSH
- řízení kvality MeSH
- technecium MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
Two fast, simple, selective and economical sample preparation methods for the determination of entecavir in biological materials available at low amounts are reported. The choice of optimal extraction techniques was performed with regard to analyte hydrophilicity, sample volumes, selectivity, method recovery and rapidity. The compatibility of the eluate with the hydrophilic interaction chromatography (HILIC) mobile phase was crucial to allow the elimination of the evaporation and reconstitution steps and to obtain acceptable peak shapes. Different types of sorbents were employed for the extraction of two biological materials (plasma and plasma ultrafiltrate). The mixed-mode polymeric sorbent MCX was chosen as a suitable one for the solid phase extraction (SPE) of plasma samples. The analytes were eluted with 1ml of the mixture of 5 % ammonium hydroxide in ACN:water (95:5). Protein precipitation (PP) with 1ml of ACN was used to remove proteins from 500μl of plasma sample prior to SPE extraction. The microextraction by packed sorbent (MEPS) was employed for the cleaning up of plasma ultrafiltrate samples due to very small volumes available for the analysis. MEPS implemented a novel sorbent based on porous graphitic carbon, semi-automatic analytical syringe and a small volume of sample (50μl). The elution step was performed using 100μl of the mixture of 5mM ammonium acetate pH 4.0:ACN (25:75). The MEPS eluate was fully compatible with HILIC mobile phase subsequently used for the analysis of entecavir, unlike SPE eluate, which had to be evaporated and reconstituted in mobile phase. Both analytical methods were validated and demonstrated good linearity in a range 1-100ng/ml (r(2)>0.9992) for plasma samples and in a range 0.5-100ng/ml (0.9991) for the plasma ultrafiltrate samples. Intra-day accuracy expressed as recovery was within the range from 80-98% for the plasma samples and 97-106% for the plasma ultrafiltrate samples. Inter-day accuracy ranged within 81-106% for the plasma and 95-101% for the plasma ultrafiltrate samples. The intra-day precision expressed as the % of RSD was lower than 4% for both matrices and inter-day precision was lower than 7% for plasma and lower than 17% for plasma ultrafiltrate. Method sensitivity reached LLOQ of 1ng/ml in plasma and 0.5ng/ml in plasma ultrafiltrate samples. The method was applied for the determination of concentration-time profiles of entecavir in plasma of the perfusate for rat kidney perfusion and for the measurement of concentration of entecavir in plasma ultrafiltrate samples. The results should be helpful in the evaluation of excretion mechanism of entecavir.
- MeSH
- acetonitrily chemie MeSH
- adsorpce MeSH
- antivirové látky krev farmakokinetika MeSH
- chemické techniky analytické MeSH
- chromatografie MeSH
- guanin analogy a deriváty krev farmakokinetika MeSH
- hydrofobní a hydrofilní interakce MeSH
- krysa rodu rattus MeSH
- limita detekce MeSH
- mikroextrakce na pevné fázi MeSH
- potkani Wistar MeSH
- referenční standardy MeSH
- reprodukovatelnost výsledků MeSH
- rozpouštědla MeSH
- tandemová hmotnostní spektrometrie MeSH
- ultrafiltrace MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
Cíl: Představení a shrnutí nejdůležitějších poznatků spojených s produkcí generátorových radionuklidů, s principy funkce a konstrukce radionuklidových generátorů s jejich využíváním v nukleární medicíně a s kontrolou kvality. Úvod: Radionuklidové generátory jsou již několik desítek let nedílnou součástí celého procesu na pracovištích nukleární medicíny. Díky nim je možné velice jednoduše získávat krátkodobé radionuklidy potřebné především pro diagnostické účely. Popis problematiky: Generátorový systém je založen na vztahu mezi mateřským a dceřiným radionuklidem. Díky jejich specifickým chemickým vlastnostem lze jednoduchou cestou získávat beznosičový preparát dceřiného radionuklidu pro další okamžité použití. Získaný radionuklid je používán buď přímo k aplikaci pacientovi, nebo je s jeho pomocí připraveno radiofarmakum, které je následně aplikováno. Abychom mohli pravidelně získávat dceřiný radionuklid, je nejprve nutné připravit radionuklid mateřský, čehož lze docílit buď v jaderném reaktoru anebo pomocí urychlovače částic. Obecný koncept radionuklidových generátorů je do jisté míry podobný, avšak jednotlivá technická provedení se výrazně odlišují. Mateřský radionuklid je zakotven v jisté chemické formě uvnitř systému, který je stíněn, a dceřiný radionuklid je následně získáván v potřebné chemické formě. Z důvodu bezpečnosti pacientů je nutné dodržovat určitá pravidla používání a kontrolovat kvalitu eluátu, aby nedocházelo k nadbytečné radiační zátěži či znehodnocení vyšetření. Závěr: Všechny výše jmenované aspekty jsou podrobněji probrány a shrnuty v rámci tohoto pojednání. Potřeba radionuklidových generátorů v nukleární medicíně je zjevná a je třeba jim věnovat pozornost. Výzkum a vývoj nových typů generátorů založených i na nových radionuklidech je velmi důležitý. S jejich pomocí budou další nové radionuklidy dostupnější a budeme opět o krok blíže personalizované medicíně.
Aim: Presentation and summarisation of the most important findings related to the production of generator radionuclides, the principles of function and construction of radionuclide generators and their use in nuclear medicine and to the quality assurance. Introduction: Radionuclide generators have been an integral part of the entire processes in nuclear medicine departments for decades. They allow to obtain short-lived radionuclides necessary for diagnostic purposes very easily. Description of issues: The generator system is based on the relationship between parent and daughter radionuclide. Due to their specific chemical properties, a carrier-free preparation of daughter radionuclide can be obtained in a simple way for immediate use. The obtained radionuclide is either used directly for administration to the patient, or a radiopharmaceutical is prepared and subsequently applied. For the obtaining of daughter radionuclide regularly, it is necessary to prepare the parent radionuclide at first, which can be achieved either in a nuclear reactor or a cyclotron. The general concept of radionuclide generators is to some extent similar, but the technical designs differ significantly. The parent radionuclide is immobilised in a certain chemical form within the system, which is shielded, and the daughter radionuclide is subsequently recovered in the certain chemical form. For patient’s safety, it is necessary to follow quality assurance rules of use and the quality control of the eluate in order to avoid unnecessary radiation exposure or the deterioration of examination. Conclusions: All of the above-mentioned aspects are discussed in more detail and summarized in this paper. The need for radionuclide generators in nuclear medicine is evident and requires attention. Research and development of new types of generators based also on new radionuclides is very important. With their help, other new radionuclides will be more accessible and we will be one step closer to the personalized medicine.
- Klíčová slova
- radionuklidový generátor,
- MeSH
- atomové reaktory MeSH
- cyklotrony MeSH
- příprava léků MeSH
- radiofarmaka * MeSH
- radionuklidy * MeSH
- řízení kvality MeSH
- Publikační typ
- práce podpořená grantem MeSH
- přehledy MeSH