Biometry
Dotaz
Zobrazit nápovědu
Autoři hodnotí na základě rozboru pooperačních výsledků 53 pacientů velikost pooperační refrakční chyby po implantací nitrooční čočky u velmi krátkých bulbů (16,0 - 20,0 mm). Vzhledem k tomu, že nejrozšířenější vzorec SRK II ve své podstatě podhodnocuje přídavek A-konstanty pro velmi krátké bulby, doporučují autoři na základě rozboru uvedeného souboru použít k výpočtu emetropizující nitrooční Čočky vzorec SRK s přepočtem A-konstanty dle axiální délky dle vztahu.: změna A-kon = 0,429*axl*axl - 18,732*axl + 206,114.
The authors evaluate the postoperative refractive results of 53 patients with extremely short eyes (16.0 - 20.0 mm) after lOL implantation. As the SRK II formula underestimates the A-constant increase for very short eyes, the authors as a results of the analysis of the set of patients recommend the A-constant recalculation accordingto formula: A-constant increase = 0.429*axl*axl - 18.732*axl + 206.114 and then the calculation of emmetropizing lOL by SRK formula.
- MeSH
- biometrie MeSH
- lidé MeSH
- nitrooční čočky metody MeSH
- oči anatomie a histologie MeSH
- pooperační období MeSH
- refrakce oka MeSH
- Check Tag
- lidé MeSH
3rd ed. XIX, 887 s.
Ciel: Cieľom tejto práce je porovnať výsledky predoperačných biometrických dát meraných na optických biometroch rozdielnej generácie u pacientov s kataraktou. Optická biometria Lenstar je založená na princípe optickej nízko-koherentnej reflektometrie (OLCR) a Anterion na swept-source optickej koherentnej tomografii (SS-OCT). Materiál a metodika: Do prospektívneho sledovania vo Fakultnej nemocnici v Trenčíne bolo v období od júna 2023 do januára 2024 zaradených 200 očí (103 pacientov). Porovnávali sme výsledky 6 parametrov: axiálna dĺžka (AL), priemerná keratometria (K), hrúbka šošovky (LT), white-to-white diameter (WTW), astigmatizmus (AST) a hodnota vymeranej vnútroočnej šošovky (IOL). Výsledky boli štatisticky spracované. Výsledky: Hodnoty parametrov AL, AST a IOL boli medzi biometrami Lenstar a Anterion zhodné, bez štatisticky významného rozdielu (p = 0,593; p = 0,089; p = 0,069). Hodnoty K, LT, WTW vykazovali štatisticky významné rozdiely (p < 0,001). Analýzou Bland-Altman grafov bola potvrdená dobrá zhoda medzi parametrami pri limite zhody 95 %. Záver: Meranie biometrických dát pomocou SS-OCT Anterion je spoľahlivé, rýchle a výsledky sú porovnateľné s výsledkami merania na Lenstar. Hodnoty AL, AST, odhadovaná IOL boli medzi biometrami zhodné. Napriek rozdielom v meraniach parametrov LT, WTW a K bola hodnota výslednej IOL rovnaká. Okrem biometrických dát Anterion poskytuje komplexné tomografické vyšetrenie rohovky a OCT sken predného segmentu
Objective: The aim of this study is to compare the results of preoperative biometric data measured with optical biometers of different generations in patients with cataract. Lenstar optical biometry is based on the principle of optical low-coherence reflectometry (OLCR), and Anterion on swept-source optical coherence tomography (SS-OCT). Material and methods: A total of 200 eyes (103 patients) were included in a prospective study at the Faculty Hospital in Trenčín the period from June 2023 to January 2024. We compared the results of 6 parameters: axial length (AL), mean keratometry (K), lens thickness (LT), white-to-white diameter (WTW), astigmatism (AST), and intraocular lens (IOL) power. The results were statistically analyzed. Results: The values of AL, AST, and IOL parameters between the Lenstar and Anterion biometers were consistent, with no statistically significant difference (p = 0.593; p = 0.089; p = 0.069). The values of K, LT, and WTW showed statistically significant differences (p < 0.001). A Bland-Altman plot analysis confirmed good concordance between the parameters within a 95% limit of agreement. Conclusion: Biometric data measurement using SS-OCT Anterion is reliable, quick, and the results are comparable to those obtained with Lenstar. The AL, AST, and estimated IOL values were consistent between the biometers. Despite differences in the measurements of LT, WTW, and K parameters, the final IOL value was the same. In addition to biometric data, Anterion provides comprehensive tomographic examination of the cornea and OCT scanning of the anterior segment.
- MeSH
- biometrie * přístrojové vybavení MeSH
- katarakta * diagnostické zobrazování patologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitrooční čočky MeSH
- oční čočka diagnostické zobrazování MeSH
- optická koherentní tomografie přístrojové vybavení MeSH
- prospektivní studie MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
V prospektivní studii 56 pacientů (67 očí) s kataraktou autoři srovnali axiální délku očí změřenou simultánně standardní ultrazvukovou biometrií a parciální koherentní interferometrií (optickou biometrií) s ohledem na výslednou pooperační refrakci operovaných očí. Dioptrická hodnota intraokulární čočky (IOČ)pro predikovanou pooperační refrakci byla stanovena pomocí vzorce SRK II. Rozdíl mezi předpokládanou a aktuální pooperační refrakcí v dioptriích byl hodnocen 3 měsíce po operaci šedého zákalu. Axiální délka změřená ultrazvukem se významně lišila od axiální délky změřené optickou biometrií (p=0,016). Také dioptrická hodnota IOČ vypočítaná podle axiální délky změřené ultrazvukem se významně lišila od dioptrické hodnoty IOČ vypočítané podle axiální délky oka změřené optickou biometrií (p=0,003). Rozdíl mezi očekávanou a skutečnou pooperační refrakcí v dioptriích však nebyl statisticky významný (p=0,384) ani s ohledem na použitou metoduměření axiální délky. Parciální koherentní interferometrie (optická biometrie) je přesná a reprodukovatelná metoda pro změření axiální délky oka před operací katarakty. Nelze ji však použít u pokročilých katarakt s neprůhlednou optickou osou, proto je stále nutná záloha standardní ultrazvukové biometrie.
In theprospectivestudyof56patientswithcataract (67eyes)theauthorscompared axial length biometry) regarding to postoperative refraction of the eyes. Dioptric power of the intraocular lens (IOL) was determined by SRK II. formula. The difference between predicted and actual postoperative refraction in the spherical equivalent were compared 3 months postoperatively. Axial length measured by ultrasound differed significantly from the axial length measured by optical biometry (p=0.016). Dioptric power of IOL calculated according to the axial length measured by ultrasound was significantly different from the dioptric power of IOL calculated according to the axial length measured by optical biometry (p=0.003). The difference between predicted and actual postoperative refraction was not statistically significant (p=0.384) even if we considered both type of measurement. In conclusion, we found partial coherence interferometry was an accurate and reproducible method for measurement of axial length of the eyebefore cataract surgery. In the cases of advanced dense cataracts backup of ultrasonic biometry is still necessary.
- MeSH
- biometrie metody přístrojové vybavení MeSH
- extrakce katarakty MeSH
- interferometrie metody přístrojové vybavení MeSH
- katarakta diagnóza ultrasonografie MeSH
- lidé MeSH
- pooperační období MeSH
- předoperační péče MeSH
- refrakce oka MeSH
- ultrasonografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
- srovnávací studie MeSH
Obstetric forceps were invented in the 1600s to assist vaginal delivery of term babies following prolonged labour. This probably explains their design, with a narrow interblade distance and long blade length, to fit a severely moulded fetal head. However, in modern obstetric practice protracted labour is avoided, yet our research has shown that over 400 years forceps dimensions have remained largely unchanged. We believe it is time to optimise these dimensions based on biometry of the term, newborn baby's head, with the head width (biparietal diameter) and head length (mentovertical diameter) correlating with interblade distance and blade length respectively. We hypothesise that doing so should reduce the incidence of neonatal complications associated with forceps assisted delivery and it is also possible that the amended shape might be associated with better outcomes for women. In this article we present our rationale for the optimisation of the forceps dimensions based on the findings of our previous systematic review and an original series of mentovertical and biparietal diameter measurements using laser scanning technology.
- MeSH
- biometrie MeSH
- hlava diagnostické zobrazování MeSH
- lidé MeSH
- novorozenec MeSH
- porodní děj * MeSH
- porodnické kleště * škodlivé účinky MeSH
- těhotenství MeSH
- vedení porodu MeSH
- Check Tag
- lidé MeSH
- novorozenec MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
Biometrie, neboli měření axiální délky oka, je prováděna u každého pacienta před operací katarakty. Spolu s keratometrií slouží pro výpočet optické mohutnosti implantované nitrooční čočky. Cílem naší práce bylo srovnat měření axiální délky oka pomocí kontaktní a imerzní ultrazvukové techniky. Ultrazvukovým přístrojem OcuScan (Alcon) byla změřena axiální délka 120 nepárových očí. Směrodatná odchylka při měření oběma technikami nepřesáhla 0,1 mm. Kontaktní technikou byla změřena průměrná axiální délka oka 23,28 mm (min. 19,31 mm, max. 31,25 mm). Při použití imerzní techniky činil průměr 23,38 mm (min. 19,38 mm, max. 31,36mm). Byl prokázán statisticky významný rozdíl mezi kontaktní a imerzní technikou měření axiální délky oka (p < 0,01). Mezi oběma ultrazvukovými biometrickými technikami byla potvrzena významná korelace (p < 0,01). V naší studii byla imerzní technikou změřena významně delší axiální délka oka než při použití techniky kontaktní. Biometrie má velký význam pro dosažení přesnosti pooperační refrakce v kataraktové chirurgii, která je v dnešní době i chirurgií refrakční. K ověření přesnosti kontaktní a imerzní techniky ultrazvukové biometrie s ohledem na cílovou pooperační refrakci je nyní prováděna retrospektivní studie.
Biometry, i. e. the measurement of the eye axial length, is performed in patients before cataract surgery. Together with keratometry, it serves for the calculation of the intraocular lens refractive (dioptric) power. The purpose of our study was to determine whether contact and immersion A-scan ultrasound techniques produce comparable measurements of the eye axial length. The axial length of 120 non-paired eyes was measured, using both contact and immersion techniques.The measurements were performed by means of an Alcon Ocuscan machine. The mean eye axial length using the contact technique was 23.28 mm (min. 19.31 mm, max. 31.25 mm), compared to the mean of 23.38 mm (min. 19.38 mm, max. 31.36 mm) gained by the immersion technique. The standard deviation of the measurements using both techniques was less than 0.1 mm. A statistically significant difference was proved between the contact and the immersion techniques (p < 0.01). There is significant correlation between both methods (p < 0.01). The eye axial length gained by means of the immersion technique was on average 0.1 mm longer than that obtained by the contact technique. Biometry is of great importance for achieving accurate postoperative target refraction in cataract surgery that is a part of refractive surgery today. It will be necessary to carry out another retrospective study with a special focus on the target postoperative refraction in order to verify the accuracy of both the biometric techniques.
X, 887 s. : tab., grafy ; 24 cm
- MeSH
- biometrie MeSH
- dospělí MeSH
- gynekologie MeSH
- lidé MeSH
- porodnictví MeSH
- prenatální diagnóza metody MeSH
- těhotenství MeSH
- ultrasonografie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- přehledy MeSH