exercise echo
Dotaz
Zobrazit nápovědu
- MeSH
- echokardiografie * metody MeSH
- hypertenze MeSH
- ischemická choroba srdeční MeSH
- lidé MeSH
- nemoci srdce * MeSH
- nemoci srdečních chlopní MeSH
- peroperační komplikace * MeSH
- předoperační péče metody MeSH
- předoperační vyšetření * metody využití MeSH
- premedikace MeSH
- rizikové faktory MeSH
- srdeční arytmie MeSH
- zátěžový test MeSH
- Check Tag
- lidé MeSH
BACKGROUND: During and after exercise, dynamic 31 P MR parameters are typically measured using an MR-compatible ergometer. Self-built equipment for local condition can be constructed where possible. PURPOSE: To develop a pedal resistance ergometer with rocker arm based on a system that combines electric weight displacement, visual self-monitoring, and exercise triggering. The repeatability and reproducibility were tested. METHODS: The hardware and software for the ergometer were constructed from commercial components in a home laboratory. Twelve volunteers participated in the testing of the ergometer. RESULTS: A fully automated ergometer system was developed, allowing the pedal resistance to be adjusted during the examination. The system includes a self-monitoring and triggering mechanism that enables both the operator and subject to monitor pedal frequency and force. The operator can modify the pedal resistance as desired during the exercise. This self-monitoring solution is simple and cost-effective, requiring only a commercial potentiometer, an Arduino converter, and a conventional video projector with a personal computer (PC). Additionally, all system components are located outside the magnetic resonance (MR) room, avoiding interference with the MR system. Results of several test of the reproducibility/repeatability of power at three pedal resistance values (15%, 24%, 25% maximal voluntary force) were expressed both as a coefficient of variation ranging from 6% to 3.1% and as an intraclass correlation of coefficient ranging from 0.96 to 0.99. Similar values were also found for other dynamic parameters of 31 P MR spectroscopy. These findings are similar to published data obtained on different types of ergometers. CONCLUSIONS: Based on more than 1 year of usage, the ergometer proved successful in handling stationary and variable loads, and can be easily operated by a single user.
OBJECTIVES: To examine the relationship of clinical, biochemical and imaging parameters to maximum oxygen uptake in patients after atrial correction of transposition of great arteries. BACKGROUND: Exercise tolerance is a key determinant of quality of life in patients with adult congenital heart disease. It is determined by a large scale of factors often different from general cardiology. METHODS: 86 consecutive patients after Senning correction of TGA were subjected to clinical and echocardiographic examination, Holter monitoring, blood tests of NT-proBNP, MRI of the heart and exercise test. Parameters of these examinations were correlated to VO2 max. RESULTS: The average age of patients was 28±3.5 years. The average systemic right ventricular function determined by MRI was 51.9±7.9 %. The average NT-proBPN was 124.3±23.6 ng/l, VO2 max. 31.7±6.5 ml/kg/min and the heart rate reserve 106±24 /min. Neither systemic right ventricular systolic function nor NT-proBPN predicted VO2 max., whereas the heart rate reserve did (p=0.003). CONCLUSION: An inability to increase heart rate during exercise noted in a considerable number of patients after atrial switch of TGA caused a decreased exercise tolerance. It is not solely the global systolic function of either ventricle that influences the exercise performance, rather it is the ability to increase heart rate and overall cardiac output appropriately (Tab. 3, Fig. 6, Ref. 28).
- MeSH
- dospělí MeSH
- echokardiografie metody přístrojové vybavení MeSH
- funkce pravé komory srdeční MeSH
- korekce transpozice velkých arterií * MeSH
- kyslík MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody přístrojové vybavení MeSH
- srdeční frekvence MeSH
- tolerance zátěže * MeSH
- transpozice velkých cév chirurgie MeSH
- zátěžový test MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- klinická studie MeSH
- práce podpořená grantem MeSH
ABSTRACT: Merrigan, JJ, Jones, MT, Malecek, J, Padecky, J, Omcirk, D, Xu, N, Peñailillo, L, and Tufano, JJ. Comparison of traditional and rest-redistribution sets on indirect markers of muscle damage following eccentric exercise. J Strength Cond Res 36(7): 1810-1818, 2022-The purpose was to investigate the effect of rest-redistribution (RR) on muscle damage after eccentric knee extensions. After 2 weeks of eccentric familiarization, 11 resistance-trained men performed 2 work-matched isokinetic unilateral eccentric knee extension protocols at 60°·s-1 using a crossover design, separated by 7 days. Subjects performed 40 repetitions with 285 seconds of rest using traditional sets (TS; 4 sets of 10 with 95 seconds of interset rest) and RR (RR; 20 sets of 2 with 15 seconds of interset rest). Muscle morphology, tensiomyography, range of motion, perceived soreness, and strength were measured before and 0, 24, 48, 72, and 96 hour after RR and TS. There were no protocol × time interactions (p < 0.05). When collapsed across protocol and compared to baseline, echo intensity of the proximal vastus lateralis was 7 ± 9% greater at 0 hour (p = 0.042), echo intensity of the distal vastus lateralis was 6 ± 7% and 9 ± 7% greater at 0 hour (p = 0.048) and 24 hour (p < 0.001), respectively, and passive ROM was 2 ± 1% lower at 48 hour (p = 0.043) after exercise. No other differences existed over time for any other variable. Thus, contrary to concentric performance where RR likely plays a large role in maintaining performance, RR during eccentric isokinetic resistance training does not strongly influence exercise performance and indications of subsequent muscle damage.
- MeSH
- biologické markery MeSH
- čtyřhlavý sval stehenní diagnostické zobrazování MeSH
- cvičení fyziologie MeSH
- kosterní svaly * fyziologie MeSH
- lidé MeSH
- odporový trénink * metody MeSH
- rozsah kloubních pohybů MeSH
- svalová síla MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- MeSH
- beta-talasemie diagnostické zobrazování MeSH
- dopplerovská echokardiografie MeSH
- dospělí MeSH
- kardiovaskulární nemoci * diagnostické zobrazování komplikace MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- mladý dospělý MeSH
- přetížení železem * diagnostické zobrazování MeSH
- zátěžový test MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
Due to the internal structure of the knee joint, the ability to characterize and quantify the dynamic response of the meniscal tissue directly in vivo is highly problematic. The main purpose of this study was to investigate the behaviour of the meniscus under loading conditions. Four healthy young females were included. To obtain T2* values in the meniscus, the vTE sequence was used with 10 echoes ranging from 0.8 to 10.1 ms. Submilisecond first echo time is a great advantage of vTE sequence allowing for precise mapping of relatively short T2*. The two-parametric least squares fitting procedure was used to calculate T2* pixel-wise. A custom-made diamagnetic apparatus was developed to simulate stress conditions on the lower limb in a conventional MR scanner. vTE T2* was performed in five consecutive scans, 6:10 min apart. Three different compartments of the medial and lateral meniscus were segmented. The differences at the different time-points were calculated. A constant increase of T2* times after compression was statistically significant in the anterior horn of the medial meniscus. T2* mapping with variable echo time sequence might be a satisfactorily sensitive technique to detect the changes of meniscus physiology under loading conditions in vivo.
- MeSH
- dospělí MeSH
- kloubní chrupavka * diagnostické zobrazování MeSH
- kolenní kloub MeSH
- lidé MeSH
- magnetická rezonanční tomografie metody MeSH
- menisky tibiální * diagnostické zobrazování fyziologie MeSH
- zátěžový test * MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
- práce podpořená grantem MeSH
- MeSH
- biokompatibilní materiály chemie terapeutické užití MeSH
- cvičení metody MeSH
- magnetická rezonanční tomografie MeSH
- protetické prostředky MeSH
- stresová inkontinence moči chirurgie prevence a kontrola terapie MeSH
- urologické chirurgické výkony metody přístrojové vybavení MeSH
- Publikační typ
- přehledy MeSH
- Geografické názvy
- Spojené státy americké MeSH
Ženské pohlaví je spojováno se zvýšeným rizikem nežádoucích příhod po chirurgické náhradě aortální chlopně, avšak s lepším výsledným stavem po katetrizační implantaci aortální chlopně (TAVI). Méně se toho již ví o rozdílech mezi pohlavími ve funkční kapacitě s těžkou aortální stenózou (AS). Cílem naší studie bylo zjistit, zda existuje rozdíl mezi pohlavími ve funkční kapacitě u skupiny asymptomatických pacientů s těžkou AS. Metoda: Asymptomatičtí pacienti s těžkou AS byli zařazováni prospektivně a absolvovali kardiopulmonální zátěžové vyšetření (cardiopulmonary exercise testing, CPET) na bicyklovém ergometru (pacient v poloze na zádech, protokol RAMP, 15 W/min). Pacienti s prokázanou ischemií byli ze studie vyřazeni. Výsledky: Do studie bylo zařazeno celkem 139 pacientů, z toho 61 žen. Při vstupním vyšetření nebyly mezi pohlavími nalezeny žádné rozdíly ve věku (66,11 vs. 64,8 roku; p = ns), echokardiografickými parametry závažnosti AS (Vmax 4,53 vs. 4,53 m/s ani Pmean 52,27 vs. 53,42 mm Hg, vše p = ns), až na hodnoty AVA (0,75 ± 0,1 vs. 0,63 ± 0,17), EF LK (68,7 vs. 71,6 %), E/e' (12,6 vs. 14,3) a BNP (92,5 vs. 103 pg/ml), vše p = ns. Ženy měly vyšší hodnoty BMI (29,5 vs. 27,3; p = 0,018), nižší VO2max (13,10 vs. 17,6 ml/kg/m2; p = 0,001) a vyšší VE/VCO2 slope (33,69 vs. 28,87; p = 0,004). K určení vztahu mezi klinickými a echokardiografickými charakteristikami s VO2max byly provedeny univariační/multivariační lineární regresní analýzy. Proměnnými nezávisle spojenými s VO2max byly ženské pohlaví (beta = ‒0,365; p = 0,002), Vmax (beta = ‒0,341; p = 0,004), věk (beta = ‒0,239; p = 0,035) a BMI (beta = ‒0,246; p = 0,028) Závěr: Ženské pohlaví je nejsilnější nezávislý prediktor snížené funkční kapacity, a to i po adjustaci na ostatní proměnné včetně BMI a echokardiografických markerů závažnosti AS. Ke zjištění, zda výše uvedená fakta nějak ovlivňují výsledný stav pacienta po onemocnění, je třeba provést další studie.
Female gender has been linked to increased risk of adverse events after surgical aortic valve replacement but with better outcome after TAVI. Less is known regarding functional capacity between the genders with severe AS. We investigated whether there is a gender difference in functional capacity in asymptomatic group of patients with severe AS. Method: Asymptomatic patients with severe AS were prospectively enrolled and underwent cardiopulmonary exercise testing (CPET) on supine ergobicycle, ramp protocol, 15 W/min. Patients with test positive for ischemia were excluded. Results: There were 139 patients, 61 women. There were no baseline gender differences in age (66.11 vs 64.8, p = ns), echo parameters of AS severity (Vmax 4.53 vs 4.53 m/s, and Pmean 52.27 vs 53.42 mmHg, all p = ns) except AVA (0.75 ± 0.1 vs 0.63 ± 0.17), LVEF (68.7 vs 71.6%), E/e' (12.6 vs 14.3) and BNP (92.5 vs 103 pg/ml), all p = ns. Women had higher body mass index (29.5 vs 27.3, p = 0.018), lower VO2max (13.10 vs 17.6 ml/kg/m2, p = 0.001) and higher VE/VCO2 slope (33.69 vs 28.87, p = 0.004). Univariable/multivariable linear regression analyses were used to test the relation between clinical and echocardiographic characteristics with VO2max. The variables independently associated with the VO2max were female gender (beta = -0.365, p = 0.002), Vmax (beta= -0.341, p = 0.004), age (beta = -0.239, p = 0.035) and BMI (beta = -0.246, p = 0.028), Conclusion: Female gender is the strongest independent predictor of decreased functional capacity, even when adjusting for other variables, including BMI and echo markers of AS severity. Further studies are needed to determine whether this finding affects the outcome of the disease
- Klíčová slova
- funkční kapacita,
- MeSH
- aortální stenóza * patofyziologie MeSH
- klinická studie jako téma MeSH
- lidé MeSH
- pohlaví MeSH
- zátěžový test MeSH
- Check Tag
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
Bolesti chodidla v oblasti paty (BP) jsou častým problémem. Jejich nejčastější příčinou je plantární fascitida. U tohoto onemocnění nejsou algoritmy diagnostických a léčebných postupů stále obecně známé. Článek se zabývá diferenciální diagnostikou, vyšetřovacími možnostmi a doporučenými léčebnými postupy.
The heel pain is a common trouble. The most frequent etiology is a plantar fasciitis, where the right diagnostic and therapeutic algorithms are still not broadly known. This article presents current opinion for differential diagnosis, diagnostic procedures and therapeutic approach..
- MeSH
- bolest etiologie MeSH
- fascie * patofyziologie ultrasonografie MeSH
- lidé MeSH
- magnetická rezonanční tomografie MeSH
- metaanalýza jako téma MeSH
- nemoci nohy (od hlezna dolů) * diagnóza terapie MeSH
- noha (od hlezna dolů) * patofyziologie ultrasonografie MeSH
- terapie cvičením MeSH
- Check Tag
- lidé MeSH