Článok predstavuje a hodnotí prelomové technologické postupy v ortodoncii: skutočný a pseudo 3D záznam, ich spracovanie a vizualizácie. Popisuje postup od celohlavového záznamu CBCT iCAT cez export do stereolitografického formátu (STL) až po jeho 3D tlač. Článok hodnotí možnosti manipulácie s týmto 3D záznamom a tiež sa detailnejšie sa venuje téme „rapid prototypingu" a perspektívam klinického využitia rôznych variant 3D tlače vrátane tlače biokompatibilnými materiálmi, napríklad titánom (AM/ EMB).
The article introduces and reviews revolutionary technologies and procedures in orthodontics: true ar pseudo 3D record, its processing and visualization. In particular, it describes procedure from CBCT iCATTM scanning through its export to stereolithographic (STL) format and final 3D print. In addition, the article reviews possibilities of 3D CBCT volume and brings the current view on rapid prototyping and perspectives of various 3D print techniques in clinical orthodontics including printing by biocompatible materials like titanium (AM/EBM).
The use of 3D visualization technologies has increased rapidly in many applied fields, including geovisualization, and has been researched from many different perspectives. However, the findings for the benefits of 3D visualization, especially in stereoscopic 3D forms, remain inconclusive and disputed. Stereoscopic "real" 3D visualization was proposed as encouraging the visual perception of shapes and volume of displayed content yet criticised as problematic and limited in a number of ways, particularly in visual discomfort and increased response time in tasks. In order to assess the potential of real 3D visualization for geo-applications, 91 participants were engaged in this study to work with digital terrain models in different 3D settings. The researchers examined the effectivity of stereoscopic real 3D visualization compared to monoscopic 3D (or pseudo 3D) visualization under static and interactive conditions and applied three tasks with experimental stimuli representing different geo-related phenomena, i.e. objects in the terrain, flat areas marked in the terrain and terrain elevation profiles. The authors explored the significant effects of real 3D visualization and interactivity factors in terms of response time and correctness. Researchers observed that the option to interact (t = -10.849, p < 0.001) with a virtual terrain and its depiction with real 3D visualization (t = 4.64, p < 0.001) extended the participants' response times. Counterintuitively, the data demonstrated that the static condition increased response correctness (z = 5.38, p < 0.001). Regarding detailed analysis of data, an interactivity factor was proposed as a potential substitute for real 3D visualization in 3D geographical tasks.
- MeSH
- Adult MeSH
- Geographic Mapping * MeSH
- Middle Aged MeSH
- Humans MeSH
- Linear Models MeSH
- Young Adult MeSH
- Computer Graphics MeSH
- Reaction Time MeSH
- Geography methods statistics & numerical data MeSH
- Imaging, Three-Dimensional methods statistics & numerical data MeSH
- Visual Perception MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Young Adult MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
Cíl: Cílem této práce bylo zhodnocení našich zkušeností s metodou 3D tisku v neurochirurgii. Vedle známé tvorby kraniálních implantátů je možné mnohem širší využití této moderní, rychle se rozvíjející technologie. Metodika: Představujeme a hodnotíme soubor našich deseti pacientů, kteří byli operováni s využitím metody 3D tisku. V oblasti cévní neurochirurgie se jednalo ve čtyřech případech o model mozkového aneuryzmatu a o jeden model arteriovenózních malformací. U dvou pacientů metoda přispěla k uzavření defektu lební baze „na míru“ tvarovanou mřížkou a v neuroonkologii u dvou pacientů zlepšila naši představu o pozici nádorů lební baze. U jednoho pacienta 3D model obratle C2 umožnil volbu optimální trajektorie fixačního materiálu. Výsledky: Ve zmíněných případech bylo dosaženo požadovaného výsledku a u všech pacientů metoda 3D tisku přispěla ke správnému ošetření. Závěr: Na základě našich zkušeností si dovolujeme konstatovat, že kromě již běžně využívané 3D implantologie metoda 3D tisku představuje zajímavou a inovativní modalitu v oblastech neurochirurgického plánování, simulace a tréninku. Předpokládáme, že se bude stále více uplatňovat v mnoha oblastech neurochirurgie.
Aim: The aim of this work was to evaluate our experience with the 3D printing method in neurosurgery. In addition to the well-known utilization of cranial implants, a significant use of this modern, rapidly developing technology is possible. Methods: We present and evaluate the series of our ten patients, which we operated on using 3D printing methods. In the field of vascular neurosurgery, four cases involved a brain aneurysm model and one arteriovenous malformation model. In two patients, this method contributed to the closure of the skull base defect with a custom-shaped cranial grid and in neuro-oncology, it improved the visualization of skull base tumors in two patients. In one patient, the 3D model of the C2 vertebra allowed the choice of the optimal trajectory of the fixation material. Results: In the mentioned cases, the desired result was achieved and the 3D printing method was adapted to the correct treatment in all patients. Conclusion: Based on our experiences, we can claim that the 3D printing method, in addition to the already commonly used 3D implantology, also presents a new and interesting modality in the field of neurosurgical planning, simulation and training. We assume that it will be increasingly used in many areas of neurosurgery.
- MeSH
- Printing, Three-Dimensional * instrumentation MeSH
- Adult MeSH
- Intracranial Aneurysm surgery diagnostic imaging MeSH
- Middle Aged MeSH
- Humans MeSH
- Central Nervous System Diseases surgery diagnostic imaging MeSH
- Neurosurgery * methods trends MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Clinical Study MeSH
- Research Support, Non-U.S. Gov't MeSH
Cílem studie bylo vyhodnotit spolehlivost jednotlivých zobrazovacích metod při posuzování průchodnosti portosystémové spojky. Autoři hodnotí výpovědní hodnotu dopplerometrického zobrazení portálního řečiště, MR portografie a rentgen-kontrastních angiografických vyšetření na vlastním souboru 24 nemocných, kterým byla v letech 1999-2003 založena portosystémová spojka pro portální hypertenzi. Na podkladě vlastních zkušeností předkládají návrh, kdy a která vyšetření indikovat, jak hodnotit jejich výsledky a kdy se spolehnout pouze na hodnocení endoskopického nálezu či celkového klinického stavu. Závěr: Doppler je dostatečně přesný pro rutinní kontroly průchodnosti portosystémové spojky, MR portografie jev této indikaci dostatečně spolehlivá i v případech, kdy je výsledek dopplerometrického vyšetření nejednoznačný, či odporuje endoskopickémji nálezu nebo klinickému stavu. Indikaci rentgen-kontrastních vyšetření k ověření průchodností portosystémové anastomózy lze považovat za oprávněnou jen ve zcela vyjimecnych situacích.
The study aimed at the evaluation of reliability of individual imaging methods in evaluation the patency of portosystemic anastomosis. The authors evaluate the information value of Doppler visualization of portal vascular bed and X-ray contrast angiographic examinations in their own cohort of 24 patients, who have been implanted a portal-systemic anastomosis for portal hypertension. Based on their own experience the authors present a recommendation when and which examinations should be indicated, how to evaluate their results and when the endoscopic examination or general clinical conditions may be reliable enough to rely upon. Conclusions: The Doppler examination is sufficiently reliable for routine control of portal-systemic anastomosis patency, MR portography is sufficiently reliable in this indication even in cases, when the results of Doppler examination is not unambiguous or contradictory to endoscopic finding or clinical condition. The X-ray contrast examinations are reliably indicated for verification of portal-systemic anastomosis patency only in exceptional cases.
- MeSH
- Adult MeSH
- Esophageal and Gastric Varices surgery complications radiography MeSH
- Liver Cirrhosis surgery radiography ultrasonography MeSH
- Middle Aged MeSH
- Humans MeSH
- Hypertension, Portal surgery complications ultrasonography MeSH
- Portography methods instrumentation MeSH
- Portasystemic Shunt, Surgical MeSH
- Splenorenal Shunt, Surgical MeSH
- Ultrasonography, Doppler methods MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Review MeSH
- Comparative Study MeSH
- MeSH
- Cells cytology MeSH
- Microscopy, Confocal * MeSH
- Humans MeSH
- Microscopy MeSH
- Imaging, Three-Dimensional * methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
Počítačový program 3D-Eye Office (Eyemaginations, USA) obsahuje názorné prezentace trojrozměrných animací z anatomie, fyziologie a patologické fyziologie celého zrakového systému. Program poskytuje možnost vytvoření různých animačních sekvencí podle individuální potřeby. Animace jsou prezentovány dataprojektorem ovládaným notebookem s dotykovou obrazovkou umožňující přímý vstup lektora do obrazu v průběhu 3D animací. Kamerový systém pro automatizované snímání a záznam průběhu vyšetření nebo léčebných postupů StreamView (Vaddio, USA) je vybavený přímým digitálním vstupem pro připojení 4 přístrojů se 4 obrazovými a 1 zvukovým výstupem. On-line sledování výkonu je umožněno prostřednictvím internetového připojení.
Software 3D Eye Office (Eyemaginations, USA) offers animations on anatomy, physiology and pathophysiology of the entire optic system, including basic ophthalmologic diagnostic and treatment steps. It allows for creation of various sequences of animations according to individual requirements. The animations are presented through a data projector and managed by a touch-screen notebook which enables a direct graphic intervention by a lecturer during animation. The camera system Stream View (Vaddio, USA) performs automated projecting and recording int the course of diagnosis or treatment. It provides direct digital access for the connection of 4 devices with four visual and one audio access. It is therefore possible during a lecture to view on-line an operation and a diagnostic or treatment process via internet.
- MeSH
- Ophthalmology * education MeSH
- Online Systems instrumentation utilization MeSH
- Image Processing, Computer-Assisted instrumentation utilization MeSH
- Education, Medical methods MeSH
- Medical Informatics Applications * MeSH
- Imaging, Three-Dimensional * instrumentation utilization MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH
- MeSH
- Algorithms MeSH
- Financing, Organized MeSH
- Humans MeSH
- Fetus MeSH
- Image Processing, Computer-Assisted MeSH
- Statistics as Topic methods MeSH
- Ultrasonography, Prenatal methods instrumentation utilization MeSH
- Image Enhancement methods MeSH
- Imaging, Three-Dimensional methods instrumentation MeSH
- Check Tag
- Humans MeSH
Úvod: Vaskularizovaný transfer lymfatických uzlin (vascularized lymph node transfer – VLNT) představuje již relativně zavedenou mikrochirurgickou techniku v léčbě lymfedému. Její užití je vhodné zejména u pokročilých stádií lymfedému, kdy již není lymfovenózní anastomóza (LVA) indikována pro pokročilou sklerotizaci lymfatických cév. Pokud je transfer uzlin prováděn izolovaně bez kožního ostrovu, jsou možnosti pooperačního monitoringu omezené. Cílem studie bylo vyhodnocení užití vysokofrekvenčního ultrazvuku s barevným dopplerem k monitoringu stopkovaných lymfatických laloků. Metody: Celkem 15 laloků bylo elevováno na stopce a. et v. thoracica lateralis u potkanů kmene Wistar. Axilární svazek byl šetřen pro zachování mobility a komfortu zvířat. Vzorek byl rovnoměrně rozdělen do 3 následujících skupin: skupina A, arteriální ischemie; skupina B, žilní okluze; skupina C, zdravá skupina. Výsledky: Ultrazvukové snímky a trojrozměrné rekonstrukce z dopplerovského ultrazvuku poskytly potřebné informace o morfologii laloků a o případných patologických změnách. Překvapivě jsme nalezli žilní průtok u skupiny A. Toto zjištění podporuje teorii pumpy a koncept venózního VLNT. Závěr: Použití trojrozměrného barevného ultrazvukového doppleru je efektivní metodou pro monitoring lymfatických laloků bez kožního ostrovu. Trojrozměrná rekonstrukce usnadňuje vizualizaci morfologie laloku a případnou detekci patologie. Tuto metodu není těžké si osvojit. Námi použité vybavení bylo uživatelsky přívětivé i v nezkušených rukách rezidenta a nálezy je možné kdykoli analyzovat zpětně, je-li to třeba. Použití trojrozměrné rekonstrukce stírá problémy spojené se subjektivním hodnocením v monitoringu VLNT.
Background: Vascularized lymph node transfer (VLNT) is a relatively well-established microsurgical treatment for lymphedema that is especially beneficial for advanced cases in which lymphovenous anastomosis is not indicated due to lymphatic vessel sclerosis. When VLNT is performed without a skin paddle, such as a buried flap, the possibilities for postoperative monitoring are limited. The aim of our study was to evaluate the use of ultra-high-frequency color Doppler ultrasound with 3D reconstruction in a pedicled axillary lymph node flap. Methods: Flaps were elevated in 15 Wistar rats based on the lateral thoracic vessels. We preserved the axillary vessels to maintain the rats’ mobility and comfort. The rats were divided into three groups as follows: Group A, arterial ischemia; group B, venous occlusion; and group C, healthy. Results: Ultrasound and color Doppler scan images revealed clear information on flap morphology changes and pathology if it was present. Surprisingly, we detected venous flow in group A rats, supporting the pump theory and venous lymph node flap concept. Conclusion: We conclude that 3D color Doppler ultrasound is an effective method for monitoring buried lymph node flaps. 3D reconstruction makes it easier to visualize the flap anatomy and detect pathology if it is present. Moreover, the learning curve for the technique is short. Our setup is user-friendly even in the inexperienced hands of a surgical resident, and images can be reevaluated at any time if necessary. The use of 3D reconstruction removes the complications associated with observer-dependent monitoring of VLNT.
- MeSH
- Surgical Flaps transplantation MeSH
- Lymphatic Vessels surgery diagnostic imaging MeSH
- Lymph Nodes * diagnostic imaging transplantation MeSH
- Lymphedema therapy MeSH
- Microsurgery methods MeSH
- Models, Animal MeSH
- Rats, Wistar MeSH
- Ultrasonography, Doppler, Color * methods MeSH
- Research MeSH
- Imaging, Three-Dimensional MeSH
- Animals MeSH
- Check Tag
- Animals MeSH
- Publication type
- Research Support, Non-U.S. Gov't MeSH