- Klíčová slova
- SS-OCT,
- MeSH
- axiální délka oka diagnostické zobrazování MeSH
- biometrie * metody přístrojové vybavení MeSH
- katarakta MeSH
- lidé MeSH
- optická koherentní tomografie * metody MeSH
- prospektivní studie MeSH
- referenční hodnoty MeSH
- rohovková topografie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- srovnávací studie MeSH
Purpose: To compare the accuracy of intraocular lens power calculation formulas and to examine the correlation of this exactness with the axial length for eyes shorter than 22.00 mm Methods: The data of hyperopic patients who underwent uneventful phacoemulsification between October 2015 and June 2019 were reviewed. The intraocular lens power for each patient was calculated using 6 formulas (Holladay1, SRK/T, Hoffer Q, Holladay 2, Haigis and Barrett Universal II) before cataract surgery. Postoperative refraction was measured, and refractive prediction error was calculated 3 months after phacoemulsification. The correlation between axial length and absolute error was evaluated. Results: Fifty-six patients (62 eyes) whose ocular axial length ranged between 20.58 mm and 21.97 mm were included in the study. The Hoffer Q formula achieved the lowest mean absolute error of 0.09 (±0.08 D). A significant correlation for the Hoffer Q (ρ = -0.329, p = 0.009) and the SRK/T (ρ = 0.321, p = 0.011) formula was observed. Conclusions: 1. The Hoffer Q formula obtained the lowest absolute error and was recommended for intraocular lens power calculation for eyeballs with axial length shorter than 22.0 mm. 2. The correlation between axial length and absolute error is a factor which should be considered when calculating intraocular lens power.
- Klíčová slova
- Hoffer Q formula,
- MeSH
- axiální délka oka MeSH
- biometrie * metody MeSH
- fakoemulzifikace MeSH
- hypermetropie MeSH
- implantace nitrooční čočky * MeSH
- lidé MeSH
- refrakce oka fyziologie MeSH
- refrakční vady * MeSH
- Check Tag
- lidé MeSH
Cíl: Cílem této práce je porovnání měřených parametrů při použití nového biometru Argos s konvenčně užívaným biometrem IOL Master 700. Soubor a metodika: Retrospektivní analýza biometrických dat u 57 pacientů (106 očí) vyšetřených na oční klinice TANA s.r.o., v Olomouci. Měření pacienta bylo prováděno na přístrojích Argos a IOL Master 700 v jeden den stejným optometristou v rámci standardní předoperační kalkulace nitrooční čočky před operací katarakty. Hodnocenými parametry byla axiální délka bulbu, hloubka přední komory, průměrná keratometrie a tloušťka čočky, které byly následně statisticky analyzovány. Výsledky: Korelace mezi všemi porovnávanými daty byla vysoká, se signifikancí p < 0,01. Při analyzování Bland-Altmanova grafu byla nalezena dobrá shoda měření při limitu shody 95 %. Axiální délky, průměrné keratometrie a tloušťky čočky nevykazovaly signifikantní rozdíl (p = 0,941; p = 0,773; p = 0,860). Průměrné keratometrie získané biometrem IOL Master 700 byly plošší, rozdíl byl ale malý a nesignifikantní. Signifikantně větší hloubky přední komory (p < 0,05) byly zaznamenány při měření přístrojem Argos. Závěr: Technologie segmentovaného refrakčního indexu, která je využívána přístrojem Argos, zapříčinila rozdíl v hodnotách hloubky přední komory. Porovnávaná celková axiální délka ale nebyla tímto v našem souboru pacientů ovlivněna. Optické biometry Argos a IOL Master 700 celkově vykazují vynikající shodu v měřených biometrických parametrech.
Purpose: To compare the biometric data obtained by the new optical biometer Argos and the conventionally used biometer IOL Master 700. Patients and methods: Retrospective analysis of the biometric data of 57 patients (106 eyes) who were examined at TANA Ophthalmology Clinic s.r.o in Olomouc. Patient measurements were carried out on both devices on the same day by the same optometrist within the standard preoperative calculation of the intraocular lens before cataract surgery. Evaluated and statistically analyzed biometric data were axial lenght, anterior chamber depth, average keratometry and lens thickness. Results: The correlation between all compared data was high, with statistical significance p < 0.01. Bland-Altman plots showed good agreement with a 95% limit of agreement. Axial lenght, average keratometry and lens thickens did not show significant differences (p = 0.941; p = 0.773; p = 0.860). IOL Master 700 showed flatter average keratometry, however, the differences were numerically small and insignificant. Anterior chamber depths obtained by Argos were longer, with a significance p < 0.05. Conclusion: The segmental refractive index technology used by Argos caused differences in anterior chamber depths. Overall axial length was, however, not, in our cohort of patients, affected by this. In general, the optical biometers Argos and IOL Master 700 show excellent agreement in the measured biometric data.
- Klíčová slova
- Argos,
- MeSH
- axiální délka oka MeSH
- biometrie * metody přístrojové vybavení MeSH
- interferometrie MeSH
- katarakta diagnóza MeSH
- lidé MeSH
- nitrooční čočky * MeSH
- optická koherentní tomografie MeSH
- reprodukovatelnost výsledků MeSH
- retrospektivní studie MeSH
- rohovkový endotel MeSH
- Check Tag
- lidé MeSH
Cíl studie: Cílem studie je zhodnocení efektivity rutinního ultrazvukového screeningu růstové restrikce ve třetím trimestru gravidity. Typ studie: Původní práce. Název a sídlo pracoviště: Gynekologicko-porodnické oddělení, Oblastní nemocnice Příbram. Metodika: Hodnocení vlivu normálního resp. abnormálního výsledku rutinního ultrazvukového screeningu růstové restrikce ve třetím trimestru gravidity na výskyt hypoxie v průběhu porodu. Výskyt abnormálních dopplerovských parametrů v jednotlivých biometrických kohortách. Hodnocení retrospektivních dat za rok 2019. Výsledky: Na našem pracovišti jsme od roku 2016 provedli vyšetření biometrie a vyšetření dopplerovské kolem 36. týdne u většiny těhotných. Zajímavým zjištěním byl nález jednoznačně abnormálních dopplerovských parametrů u patnácti "eutrofických" gravidit nad 10. percentilem. Zároveň se u 20 % plodů mezi 10. a 20. percentilem s původně normálními dopplerovskými parametry vyvinuly následně patologické parametry a/nebo plody stagnovaly v růstu. Všechny tyto gravidity byly spojeny s významným výskytem hypoxie v průběhu porodu. Závěr: Považujeme za přínosné vyšetření dopplerovských parametrů u všech plodů pod 20. percentilem, jejich dispenzarizaci a v případě stagnace růstu a/nebo zhoršení průtokových parametrů včasné ukončení gravidity.
Objective: The aim of the study is to evaluate the efficiency of routine ultrasound screening of fetal growth restriction in third trimester of pregnancy. Design: Original paper. Setting: Department of Obstetrics and Gynecology, Regional Hospital Příbram. Methods: Evaluation of the impact of normal or abnormal result of routine ultrasound screening of fetal growth restriction in third trimester of pregnancy on the incidence of hypoxia during labour. Incidence of abnormal Doppler parameters in an individual biometric cohorts. Evaluation of retrospective dates from year 2019. Results: In our department, we measure fetal biometry and Doppler parameters routinely in majority of pregnant women about 36. weeks of gestation, from year 2016. An interesting finding was detection of a definite abnormal Doppler parameters in 15 "eutrophic" pregnancies above the 10th centile. Equally 20 % of all fetuses between 10th and 20th centile with initially normal Doppler parameters developed subsequently patologic parameters and/or growth stagnation. All of these pregnancies were associated with high proportion of hypoxia during labour. Conclusion: We consider benefit from examination Doppler parameters in all fetuses under the 20th centile, their dispensarisation, and in case of growth- stagnation or/and Doppler worsening, prompt pregnancy termination.
- MeSH
- biometrie metody MeSH
- hypoxie plodu diagnostické zobrazování MeSH
- lidé MeSH
- retrospektivní studie MeSH
- růstová retardace plodu * diagnostické zobrazování MeSH
- těhotenství MeSH
- ultrasonografie dopplerovská metody MeSH
- ultrasonografie prenatální metody MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
Background: This study clarified some of anatomical relationships between the anterior clinoid process (ACP) and its surrounding structures, and identified a few major variations, important for clinical practice, especially for neurosurgeons in some skull base approaches to the cavernous sinus and paraclinoidal region lesions. Objective: The purpose of this paper is to show and prove morphometric variations of structures of sphenoid bone, the presence of caroticoclinoid foramen and types of ocular fissures and their practical significance primarily in neurosurgery in pituitary access and aneurysm surgery as well as comparison with other populations to prove the existence of difference between populations. Methods: By using classic anatomic methods-measurements 100 macerated and degenerated skulls were analyzed. With manual caliper, basal width, length and depth of anterior clinoid processes were measured. Furthermore, presence of different types of caroticoclinoid foramens, their diameters and presence of bone out-coming structures at the edges of superior orbital fissure (SOF) were analyzed. Results: We have found that optic strut (OS) was mainly adjusted in the first two fifths of the ACP (right side 42%, left 47.8%). We also noted that the basal width, length and depth of anterior clinoid process at the right side were 8.45±1.56 mm, 11.54 ±1.45 mm, 4.03±0.82 mm, and at the left side were 8.53±1.64 mm, 11.38±1.43 mm and 4.02±0.76 mm respectively. The greatest difference, due to sexes and side of skull, was presented with the incomplete type of caroticoclinoid foramen (CCF), which is much more frequent in males, placed to the right (39%) and to the left (31%). Same appearance at females is presented at the right side with 14% and at the left side with 9%. The average value of transversal foramen’s diameter was 3.55±2.55 mm. Conclusion: Incidence of appearance of interclinoid bone bridges in our study, on the sample of 100 skulls (200 sides) was 33% with significant difference between sexes. We used this sample to analyze the percent of different types of SOF in terms of analyzing the difference between sexes.
Tento článek se zabývá zpracovávání osobních údajů při používání aplikací, které monitorují a vyhodnocují zdravotní stav člověka, a to jak aplikací, které se zaměřují na spotřebitele, tak aplikací, které používají lékaři pro zhodnocení zdravotního stavu pacienta. Tyto aplikace vyhodnocují pomocí algoritmů biometrické údaje shromážděné při používání aplikace uživatelem. Jelikož zdravotní aplikace vyhodnocují velké množství osobních údajů, znamená toto zpracování riziko pro práva a svobody fyzických osob. Pokud správce nebo zpracovatel poruší právní předpisy upravující zpracovávání osobních údajů, má subjekt údajů nárok na náhradu škody, která mu porušením těchto předpisů vznikla.
This article deals with the processing of personal data by the use of applications that monitor and evaluate human health, both consumer-focused applications, and applications used by doctors to assess the patient's health. By means of algorithms, these applications evaluate biometric data collected from users. Because the health applications evaluate a large amount of personal data, the processing of such data involves a risk to the rights and freedoms of individuals. If a controller or processor violates the law on the processing of personal data, the data subject is entitled to compensation for damages resulting from the breach of the data protection regulation.
- Klíčová slova
- optická biometrie, keratometrie, ultrazvuková biometrie,
- MeSH
- biometrie * metody MeSH
- diagnostické techniky oftalmologické * MeSH
- lidé MeSH
- nitrooční čočky MeSH
- refraktometrie metody MeSH
- ultrasonografie metody MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
- MeSH
- asfyxie diagnóza MeSH
- biometrie metody MeSH
- dopravní nehody MeSH
- ethanol analýza otrava MeSH
- inzulin analýza otrava MeSH
- iris anatomie a histologie MeSH
- lidé MeSH
- morfin analýza metabolismus MeSH
- mydriáza chemicky indukované MeSH
- patologický nystagmus chemicky indukované MeSH
- pití alkoholu patofyziologie škodlivé účinky MeSH
- sklivec chemie metabolismus účinky léků MeSH
- soudní toxikologie * MeSH
- Check Tag
- lidé MeSH