INTRODUCTION/AIMS: Prospective, randomized, controlled trials of intravenous immunoglobulin (IVIG) maintenance therapy in myasthenia gravis (MG) are lacking. In this trial, we evaluated the safety and efficacy of caprylate/chromatography-purified IVIG; (IGIV-C) in patients with generalized MG undergoing standard care. METHODS: Sixty-two patients enrolled in this phase 2, multicenter, international, randomized trial (1:1 IGIV-C [2 g/kg loading dose; 1 g/kg every 3 weeks through week 21] or placebo). Efficacy was assessed by changes in Quantitative MG (QMG) score at week 24 versus baseline (primary endpoint) and percentage of patients with clinical improvement in QMG, MG Composite (MGC), and MG-Activities of Daily Living (MG-ADL) scores (secondary endpoints). Safety assessments reported all adverse events (AEs). RESULTS: The change in QMG at 24 weeks was -5.1 for IGIV-C and -3.1 for placebo (p = .187). Seventy percent of patients in the IGIV-C group had improvement in MG-ADL (≥2-point decrease) versus 40.6% in the placebo group (p = .025). Patients showing clinical improvement in QMG and MGC (≥3-point decrease) were 70.0% for IGIV-C versus 59.4% for placebo (p = .442) and 60.0% for IGIV-C versus 53.1% for placebo (p = .610). IGIV-C was well tolerated; serious AEs were similar between arms. Three of four MG exacerbations requiring hospitalizations occurred in the IGIV-C arm with one death. DISCUSSION: Several efficacy parameters showed numerical results greater than those seen in the placebo group. This was a small study and may have been underpowered to see significant differences. Additional studies may be warranted to fully determine the efficacy of IVIG maintenance therapy in MG.
- MeSH
- autoprotilátky krev MeSH
- činnosti denního života MeSH
- dospělí MeSH
- dvojitá slepá metoda MeSH
- imunologické faktory terapeutické užití škodlivé účinky aplikace a dávkování MeSH
- intravenózní imunoglobuliny * terapeutické užití škodlivé účinky aplikace a dávkování MeSH
- lidé středního věku MeSH
- lidé MeSH
- myasthenia gravis * farmakoterapie MeSH
- prospektivní studie MeSH
- receptory cholinergní * imunologie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky, fáze II MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
PURPOSE: The aim of this study was to develop a simple, robust, and easy-to-use calibration procedure for correcting misalignments in rosette MRI k-space sampling, with the objective of producing images with minimal artifacts. METHODS: Quick automatic calibration scans were proposed for the beginning of the measurement to collect information on the time course of the rosette acquisition trajectory. A two-parameter model was devised to match the measured time-varying readout gradient delays and approximate the actual rosette sampling trajectory. The proposed calibration approach was implemented, and performance assessment was conducted on both phantoms and human subjects. RESULTS: The fidelity of phantom and in vivo images exhibited significant improvement compared with uncorrected rosette data. The two-parameter calibration approach also demonstrated enhanced precision and reliability, as evidenced by quantitative T2*$$ {\mathrm{T}}_2^{\ast } $$ relaxometry analyses. CONCLUSION: Adequate correction of data sampling is a crucial step in rosette MRI. The presented experimental results underscore the robustness, ease of implementation, and suitability for routine experimental use of the proposed two-parameter rosette trajectory calibration approach.
- MeSH
- algoritmy * MeSH
- artefakty * MeSH
- fantomy radiodiagnostické * MeSH
- kalibrace MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- počítačové zpracování obrazu * metody MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
AIM: A diabetes-related foot ulcer (DFU) is a major risk factor for lower-extremity amputation (LEA). To help clinicians predict the risk of LEA in people with DFU, the Diabetic Foot Risk Assessment (DIAFORA) system was developed but has never been externally validated. METHODS: In this study, 317 people presenting with a new DFU were included. At baseline, participants were grouped into three groups based on their DIAFORA score: low-risk (<15), medium-risk (15-25), and high-risk (>25). Participants were followed until healing, LEA, death, or at least 3 months. Discriminative accuracy was evaluated using sensitivity, specificity, likelihood ratios (LRs) and the area under the curve (AUC). RESULTS: All 317 participants completed at least 3 months of follow-up for a median duration of 146 days, during which 12.6% underwent minor amputation and 2.5% major amputation. People in the low- and medium-risk categories had major amputation rates of 0.9% and 2.1%, respectively, and negative LR of major LEA of 0.10 and 0.38, respectively, while the people in the high-risk category had an amputation rate of 25.0% and a positive LR of 12.9. The DIAFORA risk groups had a sensitivity of 75.0% and a specificity of 65.7%, with a corresponding AUC of 0.78 (95% CI 0.68-0.87) for the prediction of major LEA. CONCLUSION: The DIAFORA score is a useful tool for risk stratification of people presenting with a newly occurred DFU, with the external validation presenting results similar to those presented in the original study. The DIAFORA score may guide clinicians towards more individualized DFU treatment regimens.
- MeSH
- amputace * statistika a číselné údaje MeSH
- diabetická noha * chirurgie epidemiologie MeSH
- dolní končetina chirurgie MeSH
- hodnocení rizik metody MeSH
- kohortové studie MeSH
- lidé středního věku MeSH
- lidé MeSH
- prediktivní hodnota testů MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- validační studie MeSH
- Geografické názvy
- Dánsko MeSH
PURPOSE: Dual velocity encoding PC-MRI can produce spurious artifacts when using high ratios of velocity encoding values (VENCs), limiting its ability to generate high-quality images across a wide range of encoding velocities. This study aims to propose and compare dual-VENC correction methods for such artifacts. THEORY AND METHODS: Two denoising approaches based on spatiotemporal regularization are proposed and compared with a state-of-the-art method based on sign correction. Accuracy is assessed using simulated data from an aorta and brain aneurysm, as well as 8 two-dimensional (2D) PC-MRI ascending aorta datasets. Two temporal resolutions (30,60) ms and noise levels (9,12) dB are considered, with noise added to the complex magnetization. The error is evaluated with respect to the noise-free measurement in the synthetic case and to the unwrapped image without additional noise in the volunteer datasets. RESULTS: In all studied cases, the proposed methods are more accurate than the Sign Correction technique. Using simulated 2D+T data from the aorta (60 ms, 9 dB), the Dual-VENC (DV) error 0.82±0.07$$ 0.82\pm 0.07 $$ is reduced to: 0.66±0.04$$ 0.66\pm 0.04 $$ (Sign Correction); 0.34±0.04$$ 0.34\pm 0.04 $$ and 0.32±0.04$$ 0.32\pm 0.04 $$ (proposed techniques). The methods are found to be significantly different (p-value <0.05$$ <0.05 $$ ). Importantly, brain aneurysm data revealed that the Sign Correction method is not suitable, as it increases error when the flow is not unidirectional. All three methods improve the accuracy of in vivo data. CONCLUSION: The newly proposed methods outperform the Sign Correction method in improving dual-VENC PC-MRI images. Among them, the approach based on temporal differences has shown the highest accuracy.
- MeSH
- algoritmy * MeSH
- aorta * diagnostické zobrazování MeSH
- artefakty * MeSH
- fantomy radiodiagnostické MeSH
- interpretace obrazu počítačem metody MeSH
- intrakraniální aneurysma diagnostické zobrazování MeSH
- lidé MeSH
- magnetická rezonanční tomografie * metody MeSH
- mozek diagnostické zobrazování MeSH
- počítačová simulace MeSH
- počítačové zpracování obrazu * metody MeSH
- poměr signál - šum * MeSH
- reprodukovatelnost výsledků MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
Magnetic resonance spectroscopic imaging (MRSI) enables the simultaneous noninvasive acquisition of MR spectra from multiple spatial locations inside the brain. Although 1H-MRSI is increasingly used in the human brain, it is not yet widely applied in the preclinical setting, mostly because of difficulties specifically related to very small nominal voxel size in the rat brain and low concentration of brain metabolites, resulting in low signal-to-noise ratio (SNR). In this context, we implemented a free induction decay 1H-MRSI sequence (1H-FID-MRSI) in the rat brain at 14.1 T. We combined the advantages of 1H-FID-MRSI with the ultra-high magnetic field to achieve higher SNR, coverage, and spatial resolution in the rat brain and developed a custom dedicated processing pipeline with a graphical user interface for Bruker 1H-FID-MRSI: MRS4Brain toolbox. LCModel fit, using the simulated metabolite basis set and in vivo measured MM, provided reliable fits for the data at acquisition delays of 1.30 ms. The resulting Cramér-Rao lower bounds were sufficiently low (< 30%) for eight metabolites of interest (total creatine, N-acetylaspartate, N-acetylaspartate + N-acetylaspartylglutamate, total choline, glutamine, glutamate, myo-inositol, and taurine), leading to highly reproducible metabolic maps. Similar spectral quality and metabolic maps were obtained with one and two averages, with slightly better contrast and brain coverage due to increased SNR in the latter case. Furthermore, the obtained metabolic maps were accurate enough to confirm the previously known brain regional distribution of some metabolites. The acquisitions proved high reproducibility over time. We demonstrated that the increased SNR and spectral resolution at 14.1 T can be translated into high spatial resolution in 1H-FID-MRSI of the rat brain in 13 min using the sequence and processing pipeline described herein. High-resolution 1H-FID-MRSI at 14.1 T provided robust, reproducible, and high-quality metabolic mapping of brain metabolites with minimal technical limitations.
- MeSH
- krysa rodu rattus MeSH
- magnetická rezonanční tomografie metody MeSH
- metabolom MeSH
- mozek * metabolismus diagnostické zobrazování MeSH
- poměr signál - šum MeSH
- potkani Sprague-Dawley MeSH
- potkani Wistar MeSH
- protonová magnetická rezonanční spektroskopie metody MeSH
- zvířata MeSH
- Check Tag
- krysa rodu rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Spinal cord injury results in permanent neurological impairment and disability due to the absence of spontaneous regeneration. NG101, a recombinant human antibody, neutralises the neurite growth-inhibiting protein Nogo-A, promoting neural repair and motor recovery in animal models of spinal cord injury. We aimed to evaluate the efficacy of intrathecal NG101 on recovery in patients with acute cervical traumatic spinal cord injury. METHODS: This randomised, double-blind, placebo-controlled phase 2b clinical trial was done at 13 hospitals in the Czech Republic, Germany, Spain, and Switzerland. Patients aged 18-70 years with acute, complete or incomplete cervical spinal cord injury (neurological level of injury C1-C8) within 4-28 days of injury were eligible for inclusion. Participants were initially randomly assigned 1:1 to intrathecal treatment with 45 mg NG101 or placebo (phosphate-buffered saline); 18 months into the study, the ratio was adjusted to 3:1 to achieve a final distribution of 2:1 to improve enrolment and drug exposure. Randomisation was done using a centralised, computer-based randomisation system and was stratified according to nine distinct outcome categories with a validated upper extremity motor score (UEMS) prediction model based on clinical parameters at screening. Six intrathecal injections were administered every 5 days over 4 weeks, starting within 28 days of injury. Investigators, study personnel, and study participants were masked to treatment allocation. The primary outcome was change in UEMS at 6 months, analysed alongside safety in the full analysis set. The completed trial was registered at ClinicalTrials.gov, NCT03935321. FINDINGS: From May 20, 2019, to July 20, 2022, 463 patients with acute traumatic cervical spinal cord injury were screened, 334 were deemed ineligible and excluded, and 129 were randomly assigned to an intervention (80 patients in the NG101 group and 49 in the placebo group). The full analysis set comprised 78 patients from the NG101 group and 48 patients from the placebo group. 107 (85%) patients were male and 19 (15%) patients were female, with a median age of 51·5 years (IQR 30·0-60·0). Across all patients, the primary endpoint showed no significant difference between groups (with UEMS change at 6 months 1·37 [95% CI -1·44 to 4·18]; placebo group mean 19·20 [SD 11·78] at baseline and 30·91 [SD 15·49] at day 168; NG101 group mean 18·23 [SD 15·14] at baseline and 31·31 [19·54] at day 168). Treatment-related adverse events were similar between groups (nine in the NG101 group and six in the placebo group). 25 severe adverse events were reported: 18 in 11 (14%) patients in the NG101 group and seven in six (13%) patients in the placebo group. Although no treatment-related fatalities were reported in the NG101 group, one fatality not related to treatment occurred in the placebo group. Infections were the most common adverse event affecting 44 (92%) patients in the placebo group and 65 (83%) patients in the NG101 group. INTERPRETATION: NG101 did not improve UEMS in patients with acute spinal cord injury. Post-hoc subgroup analyses assessing UEMS and Spinal Cord Independence Measure of self-care in patients with motor-incomplete injury indicated potential beneficial effects that require investigation in future studies. FUNDING: EU program Horizon2020; Swiss State Secretariat for Education, Research and Innovation; Wings for Life; the Swiss Paraplegic Foundation; and the CeNeReg project of Wyss Zurich (University of Zurich and Eidgenössische Technische Hochschule Zurich).
- MeSH
- dospělí MeSH
- dvojitá slepá metoda MeSH
- krční mícha * zranění MeSH
- krční obratle MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- Nogo proteiny * MeSH
- poranění míchy * farmakoterapie MeSH
- senioři MeSH
- spinální injekce * MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky, fáze II MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
Fast Photochemical Oxidation of Proteins (FPOP) is a promising technique for studying protein structure and dynamics. The quality of insight provided by FPOP depends on the reliability of the determination of the modification site. This study investigates the performance of two search engines, Mascot and PEAKS, for the data processing of FPOP analyses. Comparison of Mascot and PEAKS of the hemoglobin--haptoglobin Bruker timsTOF data set (PXD021621) revealed greater consistency in the Mascot identification of modified peptides, with around 26% of the IDs being mutual for all three replicates, compared to approximately 22% for PEAKS. The intersection between Mascot and PEAKS results revealed a limited number (31%) of shared modified peptides. Principal Component Analysis (PCA) using the peptide-spectrum match (PSM) score, site probability, and peptide intensity was applied to evaluate the results, and the analyses revealed distinct clusters of modified peptides. Mascot showed the ability to assess confident site determination, even with lower PSM scores. However, high PSM scores from PEAKS did not guarantee a reliable determination of the modification site. Fragmentation coverage of the modification position played a crucial role in Mascot assignments, while the AScore localizations from PEAKS often become ambiguous because the software employs MS/MS merging.
In recent years, several international urological societies have published guidelines on the diagnosis, treatment, and follow-up of urethral strictures, but a guideline for the German-speaking region has not been available to date. This summary provides a detailed comparison of the guidelines of the European Association of Urology (EAU), American Urological Association (AUA) and the Société Internationale d'Urologie (SIU) with regard to the treatment of anterior urethral strictures, i.e. from the bulbar urethra to the meatus. In the following work, differences and specific recommendations in the guidelines are highlighted. In particular, the three guidelines largely agree with regard to diagnostic workup and follow-up. However, divergences exist in the management of anterior urethral strictures, particularly with regard to the use of endoscopic therapeutic approaches and the use of urethral stents. In addition, the EAU provides more comprehensive and detailed recommendations on urethroplasty techniques and specific patient follow-up. The EAU guidelines are the most current and were the first to include instructions for urethral strictures in women and individuals with gender incongruence after genital approximation surgery. Reconstructive urology is a rapidly evolving specialty and, thus, the clinical approach has been changing accordingly. Although guideline recommendations have become more inclusive and comprehensive, more high-quality data are needed to further improve the level of evidence.
- MeSH
- lidé MeSH
- správnost dat MeSH
- striktura uretry * diagnóza MeSH
- uretra chirurgie MeSH
- urologie * MeSH
- zákroky plastické chirurgie * MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- anglický abstrakt MeSH
- časopisecké články MeSH
- přehledy MeSH
- Geografické názvy
- Spojené státy americké MeSH
Acquiring pulmonary circulation parameters as a potential marker of cardiopulmonary function is not new. Methods to obtain these parameters have been developed over time, with the latest being first-pass perfusion sequences in cardiovascular magnetic resonance (CMR). Even though more data on these parameters has been recently published, different nomenclature and acquisition methods are used across studies; some works even reported conflicting data. The most commonly used circulation parameters obtained using CMR include pulmonary transit time (PTT) and pulmonary transit beats (PTB). PTT is the time needed for a contrast agent (typically gadolinium-based) to circulate from the right ventricle (RV) to the left ventricle (LV). PTB is the number of cardiac cycles the process takes. Some authors also include corrected heart rate (HR) versions along with standard PTT. Besides other methods, CMR offers an option to assess stress circulation parameters, but data are minimal. This review aims to summarize the up-to-date findings and provide an overview of the latest progress on this promising, dynamically evolving topic.
Endometrial biopsies are important in the diagnostic workup of women who present with abnormal uterine bleeding or hereditary risk of endometrial cancer. In general, approximately 10% of all endometrial biopsies demonstrate endometrial (pre)malignancy that requires specific treatment. As the diagnostic evaluation of mostly benign cases results in a substantial workload for pathologists, artificial intelligence (AI)-assisted preselection of biopsies could optimize the workflow. This study aimed to assess the feasibility of AI-assisted diagnosis for endometrial biopsies (endometrial Pipelle biopsy computer-aided diagnosis), trained on daily-practice whole-slide images instead of highly selected images. Endometrial biopsies were classified into 6 clinically relevant categories defined as follows: nonrepresentative, normal, nonneoplastic, hyperplasia without atypia, hyperplasia with atypia, and malignant. The agreement among 15 pathologists, within these classifications, was evaluated in 91 endometrial biopsies. Next, an algorithm (trained on a total of 2819 endometrial biopsies) rated the same 91 cases, and we compared its performance using the pathologist's classification as the reference standard. The interrater reliability among pathologists was moderate with a mean Cohen's kappa of 0.51, whereas for a binary classification into benign vs (pre)malignant, the agreement was substantial with a mean Cohen's kappa of 0.66. The AI algorithm performed slightly worse for the 6 categories with a moderate Cohen's kappa of 0.43 but was comparable for the binary classification with a substantial Cohen's kappa of 0.65. AI-assisted diagnosis of endometrial biopsies was demonstrated to be feasible in discriminating between benign and (pre)malignant endometrial tissues, even when trained on unselected cases. Endometrial premalignancies remain challenging for both pathologists and AI algorithms. Future steps to improve reliability of the diagnosis are needed to achieve a more refined AI-assisted diagnostic solution for endometrial biopsies that covers both premalignant and malignant diagnoses.
- MeSH
- biopsie MeSH
- hyperplazie MeSH
- lidé MeSH
- počítače * MeSH
- reprodukovatelnost výsledků MeSH
- studie proveditelnosti MeSH
- umělá inteligence * MeSH
- Check Tag
- lidé MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH